Radiation Dose to the Lens Using Different Temporal Bone CT Scanning Protocols

被引:30
|
作者
Niu, Y. [1 ]
Wang, Z. [1 ]
Liu, Y. [1 ]
Liu, Z. [1 ]
Yao, V. [2 ]
机构
[1] Capital Med Univ, Dept Radiol, Beijing Tongren Hosp, Beijing 100730, Peoples R China
[2] Philips Healthcare, Beijing, Peoples R China
关键词
HIGH-RESOLUTION CT; COMPUTED-TOMOGRAPHY; PETROUS BONE;
D O I
10.3174/ajnr.A1807
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Temporal bone CT is performed frequently in clinical practice. At the same time, the eye lens are exposed to ionizing radiation without any useful diagnostic information delivered. Our aim was to investigate the radiation dose to the lens of the eye by using temporal bone CT scanning with different protocols. MATERIALS AND METHODS: Direct axial and coronal CT by using a conventional sequential scanning mode (140 kV, 220 mAs/section, 1.25-mm thickness, 1.25-mm increment, 16 x 0.625 mm collimation, the glabellomeatal line as a scanning baseline), a routine helical scanning mode (140 kV, 220 mAs/section, 0.315 pitch, 0.67-mm thickness, 0.33-mm increment, 16 X 0.625 collimation, the orbitomeatal line as a scanning baseline), and a modified helical scanning mode (acanthiomeatal line as a scanning baseline; other parameters, same as above) was performed on an exsomatized cadaveric head. CTDl(vol) and DLP were recorded for each scanning mode, and effective doses were calculated. Organ doses for the lens were measured with TLDs. RESULTS: When the sequential scanning mode was used, the gross effective dose was 1.21 mSv and the organ dose to the lens was 50.96 and 1.73 mGy, respectively, for direct axial and coronal imaging. The effective dose was 0.803 mSv in routine helical scanning, while the lens dose was 40.17 mGy. With the modified helical scanning mode, the effective dose was as same as that for the routine helical scanning, but the lens dose was reduced significantly to 10.33 mGy. CONCLUSIONS: The effective doses resulting from sequential axial and coronal scanning were 1.51 times higher than the dose from helical scanning, and the lens dose was 1.31 times higher. With the modified helical scanning mode, thinner section images could be used to reformat axial, coronal, and sagittal images with a further 74.3% reduction in lens dose beyond that achieved with the conventional helical protocol.
引用
收藏
页码:226 / 229
页数:4
相关论文
共 50 条
  • [31] Evaluation of coronary CT scans radiation dose and image quality using different scanning protocol on a 256-slice CT scanner
    Fareed, A. M.
    Pernes, J. M.
    Gaux, J. C.
    Oraby, M.
    Nasr, G. M.
    Maklady, F.
    Dupouy, P.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2010, 12 (0F) : F90 - F90
  • [32] RADIATION EXPOSURE TO THE LENS OF THE EYE IN TEMPORAL BONE RADIOGRAPHY
    PAIX, D
    HOGBEN, D
    ROBERTSON, A
    AUSTRALASIAN RADIOLOGY, 1980, 24 (03): : 235 - 237
  • [33] Radiation Dose Optimization during Temporal Bone CT Examination Using One-Shot Axial Volumetric Acquisition
    Madkouri Y.
    Aggour M.
    Bouzekraoui Y.
    Bentayeb F.
    Iranian Journal of Medical Physics, 2023, 20 (04) : 215 - 221
  • [34] New CT scanning approach for decreasing radiation dose
    Miyazaki, O
    Nakazawa, T
    Takagi, H
    IMAGE DISPLAY - MEDICAL IMAGING 1998, 1998, 3335 : 655 - 662
  • [35] Radiation dose from CT scanning: can it be reduced?
    Trinavarat, Panruethai
    Kritsaneepaiboon, Supika
    Rongviriyapanich, Chantima
    Visrutaratna, Pannee
    Srinakarin, Jiraporn
    ASIAN BIOMEDICINE, 2011, 5 (01) : 13 - 21
  • [36] Radiation Dose Associated With Over Scanning in Neck CT
    Badawy, Mohamed Khaldoun
    Lane, Hannah
    Galea, Michael
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2019, 48 (04) : 359 - 362
  • [37] Radiation dose-reduction strategies for neuroradiology CT protocols
    Smith, A. B.
    Dillon, W. P.
    Gould, R.
    Wintermark, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (09) : 1628 - 1632
  • [38] Radiation dose in cardiac CT angiography: protocols and image quality
    Oliveira, L. C. G.
    Gottlieb, I.
    Rizzi, P.
    Lopes, R. T.
    Kodlulovich, S.
    RADIATION PROTECTION DOSIMETRY, 2013, 155 (01) : 73 - 80
  • [39] Reducing Radiation Dose in Body CT: A Practical Approach to Optimizing CT Protocols
    Goldman, Alice R.
    Maldjian, Pierre D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 748 - 754
  • [40] Optimizing CT image protocols with respect to quality and radiation dose
    Cody, D.
    Kofler, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2539 - 2539