Radiation Dose to the Lens Using Different Temporal Bone CT Scanning Protocols

被引:30
|
作者
Niu, Y. [1 ]
Wang, Z. [1 ]
Liu, Y. [1 ]
Liu, Z. [1 ]
Yao, V. [2 ]
机构
[1] Capital Med Univ, Dept Radiol, Beijing Tongren Hosp, Beijing 100730, Peoples R China
[2] Philips Healthcare, Beijing, Peoples R China
关键词
HIGH-RESOLUTION CT; COMPUTED-TOMOGRAPHY; PETROUS BONE;
D O I
10.3174/ajnr.A1807
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Temporal bone CT is performed frequently in clinical practice. At the same time, the eye lens are exposed to ionizing radiation without any useful diagnostic information delivered. Our aim was to investigate the radiation dose to the lens of the eye by using temporal bone CT scanning with different protocols. MATERIALS AND METHODS: Direct axial and coronal CT by using a conventional sequential scanning mode (140 kV, 220 mAs/section, 1.25-mm thickness, 1.25-mm increment, 16 x 0.625 mm collimation, the glabellomeatal line as a scanning baseline), a routine helical scanning mode (140 kV, 220 mAs/section, 0.315 pitch, 0.67-mm thickness, 0.33-mm increment, 16 X 0.625 collimation, the orbitomeatal line as a scanning baseline), and a modified helical scanning mode (acanthiomeatal line as a scanning baseline; other parameters, same as above) was performed on an exsomatized cadaveric head. CTDl(vol) and DLP were recorded for each scanning mode, and effective doses were calculated. Organ doses for the lens were measured with TLDs. RESULTS: When the sequential scanning mode was used, the gross effective dose was 1.21 mSv and the organ dose to the lens was 50.96 and 1.73 mGy, respectively, for direct axial and coronal imaging. The effective dose was 0.803 mSv in routine helical scanning, while the lens dose was 40.17 mGy. With the modified helical scanning mode, the effective dose was as same as that for the routine helical scanning, but the lens dose was reduced significantly to 10.33 mGy. CONCLUSIONS: The effective doses resulting from sequential axial and coronal scanning were 1.51 times higher than the dose from helical scanning, and the lens dose was 1.31 times higher. With the modified helical scanning mode, thinner section images could be used to reformat axial, coronal, and sagittal images with a further 74.3% reduction in lens dose beyond that achieved with the conventional helical protocol.
引用
收藏
页码:226 / 229
页数:4
相关论文
共 50 条
  • [21] Radiation Dose for Multiregion CT Protocols: Challenges and Limitations
    Singh, Ramandeep
    Szczykutowicz, Timothy P.
    Homayounieh, Fatemeh
    Vining, Rachel
    Kanal, Kalpana
    Digumarthy, Subba R.
    Kalra, Mannudeep K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (05) : 1100 - 1106
  • [22] CT protocols: balancing radiation dose and image quality
    Fotter, Richard
    PEDIATRIC RADIOLOGY, 2011, 41 : S215 - S216
  • [23] Pointers for Optimizing Radiation Dose in Chest CT Protocols
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Thrall, James H.
    Mahesh, Mahadevappa
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2011, 8 (09) : 663 - 665
  • [24] Radiation dose during CT scan with PET/CT clinical protocols
    Son, Hye-Kyung
    Lee, Sang Hoon
    Nam, Sora
    Kim, Hee-Joung
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2210 - 2214
  • [25] The effective dose of different scanning protocols using the Sirona GALILEOS® comfort CBCT scanner
    Chambers, D.
    Bohay, R.
    Kaci, L.
    Barnett, R.
    Battista, J.
    DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (02)
  • [26] CT pre-TAVI: image quality and radiation dose in 13 different acquisition protocols
    Martini, Chiara
    Disalvo, Rossella
    Cicala, Gloria
    Palumbo, Alessandro Anselmo
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0J) : J206 - J207
  • [27] Dental-CT: Image quality and absorbed radiation dose of different scan protocols.
    Schorn, C
    Visser, H
    Hermann, KP
    Alamo, L
    Funke, M
    Grabbe, E
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (02): : 137 - 144
  • [28] Reduction of CT radiation dose in PET-CT: evaluation of low dose CT scan protocols
    Palimieri, A.
    Bertolini, V.
    COla, S.
    Piccagli, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S777 - S777
  • [29] Image quality and radiation dose of different scanning protocols in DSCT cardiothoracic angiography for children with tetralogy of fallot
    Yanhua Duan
    Li Chen
    Dawei Wu
    Baoting Chao
    Zhaoping Cheng
    Xin Yan
    Shuo Zhao
    Baojin Chen
    Min Xu
    Ximing Wang
    Guangming Lu
    The International Journal of Cardiovascular Imaging, 2020, 36 : 1791 - 1799
  • [30] Image quality and radiation dose of different scanning protocols in DSCT cardiothoracic angiography for children with tetralogy of fallot
    Duan, Yanhua
    Chen, Li
    Wu, Dawei
    Chao, Baoting
    Cheng, Zhaoping
    Yan, Xin
    Zhao, Shuo
    Chen, Baojin
    Xu, Min
    Wang, Ximing
    Lu, Guangming
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (09): : 1791 - 1799