Dual-energy CT angiography of abdomen with routine concentration contrast agent in comparison with conventional single-energy CT with high concentration contrast agent

被引:25
|
作者
He, Jingzhen [1 ]
Wang, Qing [1 ]
Ma, Xiangxing [1 ]
Sun, Zhiyuan [1 ]
机构
[1] Shandong Univ, Qilu Hosp, Dept Radiol, Jinan 250012, Shandong, Peoples R China
关键词
Dual-energy CT; CT angiography; Contrast agent; REDUCED IODINE LOAD; IMAGE-QUALITY; SPECTRAL CT; PULMONARY ANGIOGRAPHY; RENAL-INSUFFICIENCY; DOSE REDUCTION; TUBE-VOLTAGE; ENHANCEMENT; OPTIMIZATION; 16-MDCT;
D O I
10.1016/j.ejrad.2014.11.025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the quantitative and subjective image quality in abdominal angiography between dual-energy CT (DECT) at the routine concentration of iodinated contrast agent (300 mg/mL) and conventional 120-kVp single-energy CT (SECT) at the high concentration of contrast agent (370 mg/mL). Materials and methods: Abdominal computed tomography angiography (CTA) was performed in 104 patients, including 56 with conventional 120-kVp SECT at the high concentration of contrast agent and 48 with DECT at the routine concentration of contrast agent. The monochromatic images at the optimal kiloelectron-voltage (key) of DECT that demonstrated the best contrast-to-noise ratio were reconstructed. The signal intensity and noise in abdominal arteries were comparatively analyzed between DECT and SECT. The image quality and visibility of the branch orders of superior mesenteric artery and renal arteries were further assessed. The radiation doses were recorded. Results: Compared with SECT, DECT demonstrated higher signal intensity, signal-to-noise ratio, and contrast-to-noise ratio (all P < 0.01) with moderately increased noise (40%, P < 0.01) in all abdominal arteries. The image quality of DECT was superior to that of SECT (P < 0.01) as evaluated with a subjective five-point scale system. Visualization of the branches of superior mesenteric artery and renal arteries was also better by DECT (P < 0.01) than SECT. The radiation dose of DECT was slight higher than that of SECT (P < 0.0001). Conclusion: DECT with image reconstruction at the optimal keV provides a high-quality angiographic technique, which allows use of a lower concentration of contrast agent compared with conventional 120-kVp SECT. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:221 / 227
页数:7
相关论文
共 50 条
  • [41] Comparison of metal artifact reduction using single-energy CT and dual-energy CT with various metallic implants in cadavers
    Barreto, Izabella
    Pepin, Eric
    Davis, Ivan
    Dean, Cooper
    Massini, Tara
    Rees, John
    Olguin, Catherine
    Quails, Nathan
    Correa, Nathalie
    Rill, Lynn
    Arreola, Manuel
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133
  • [42] Dual-energy CT for the detection of skull base invasion in nasopharyngeal carcinoma: comparison of simulated single-energy CT and MRI
    Zhan, Yang
    Wang, Peng
    Wang, Yuzhe
    Wang, Yin
    Tang, Zuohua
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [43] CT Detection of Myocardial Blood Volume Deficits: Dual-Energy CT Compared With Single-Energy CT Spectra
    Arnoldi, Elisabeth
    Ruzsics, Balazs
    Lee, Yeong Shyan
    Gebregziabher, Mulugeta
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Costello, Philip
    Schoepf, U. Joseph
    CIRCULATION, 2009, 120 (18) : S375 - S375
  • [44] Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning
    Zhu, Jiahua
    Penfold, Scott N.
    MEDICAL PHYSICS, 2016, 43 (06) : 2845 - 2854
  • [45] Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography
    Meier, A.
    Wurnig, M.
    Desbiolles, L.
    Leschka, S.
    Frauenfelder, T.
    Alkadhi, H.
    CLINICAL RADIOLOGY, 2015, 70 (11) : 1244 - 1251
  • [46] The initial experience of the upper abdominal CT angiography using low-concentration contrast medium on dual energy spectral CT
    Xin, Lei
    Yang, Xiaotang
    Huang, Ning
    Du, Xiaosong
    Zhang, Jianxin
    Wang, Yanyan
    Hou, Lina
    Gao, Jinfang
    ABDOMINAL IMAGING, 2015, 40 (07): : 2894 - 2899
  • [47] The initial experience of the upper abdominal CT angiography using low-concentration contrast medium on dual energy spectral CT
    Lei Xin
    Xiaotang Yang
    Ning Huang
    Xiaosong Du
    Jianxin Zhang
    Yanyan Wang
    Lina Hou
    Jinfang Gao
    Abdominal Imaging, 2015, 40 : 2894 - 2899
  • [48] Impact of Intravenously Injected Contrast Agent on Bone Mineral Density Measurement in Dual-Source Dual-Energy CT
    Koch, Vitali
    Albrecht, Moritz H.
    Gruenewald, Leon D.
    Yel, Ibrahim
    Eichler, Katrin
    Gruber-Rouh, Tatjana
    Hammerstingl, Renate M.
    Burck, Iris
    Wichmann, Julian L.
    Alizadeh, Leona S.
    Vogl, Thomas J.
    Lenga, Lukas
    Wesarg, Stefan
    Martin, Simon S.
    Mader, Christoph
    Dimitrova, Mirela
    D'Angelo, Tommaso
    Booz, Christian
    ACADEMIC RADIOLOGY, 2022, 29 (06) : 880 - 887
  • [49] Conversion of single-energy CT to parametric maps of dual-energy CT using convolutional neural network
    Kim, Sangwook
    Lee, Jimin
    Kim, Jungye
    Kim, Bitbyeol
    Choi, Chang Heon
    Jung, Seongmoon
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1158): : 1180 - 1190
  • [50] Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics
    Majida Nehnahi
    Gabriel Simon
    Romain Moinet
    Gael Piton
    Camille Camelin
    Maxime Ronot
    Éric Delabrousse
    Paul Calame
    Scientific Reports, 13