A Novel Percentage-Based System for Determining Aseptic Loosening of Total Knee Arthroplasty Tibial Components

被引:20
|
作者
Chalmers, Brian P. [1 ]
Sculco, Peter K. [1 ]
Fehring, Keith A. [1 ]
Trousdale, Robert T. [1 ]
Taunton, Michael J. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, 200 First St SW, Rochester, MN 55905 USA
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 07期
关键词
tibial; loosening; aseptic; total knee arthroplasty; revision; RADIOLUCENT LINES; FAILING TODAY; CONTACT-STRESS; FAILURE; REVISION; STERILIZATION; REPLACEMENT; WEAR; POLYETHYLENE; MECHANISMS;
D O I
10.1016/j.arth.2017.02.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: There are limited data on evaluating the significance of radiolucent lines and aseptic loosening in total knee arthroplasty (TKA). We sought to compare the sensitivity, specificity, and reliability of the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System (KSRES) in detecting tibial component loosening compared to a novel percentage-based system (PBS). Methods: We retrospectively reviewed radiographs obtained from 48 patients within 6 months prior to revision TKA. The radiographs were randomized and four reviewers independently used the KSRES to categorize tibial implants as nonconcerning, clinical follow-up for progression, or loose as described by KSRES. For the PBS, the percent involvement of the tibial implant interface of any radiolucency at the bone-cement or cement-implant interface was determined. The higher percentage from either the anteroposterior or the lateral image was the final score. Components were categorized as nonconcerning (<= 10%), clinical follow-up for progression (11%-24%), or loose (>= 25%). We compared the sensitivity, specificity, and interobserver reliability using intraoperative assessment of implant fixation as the gold standard. Results: For the KSRES, the mean sensitivity for determining tibial loosening was 7.3% and mean specificity for determining a nonconcerning implant was 95.9%. The PBS significantly increased the sensitivity to 91.1% (P < .001) while maintaining a specificity of 87.9% (P = .2). Interobserver reliability significantly increased from a mean kappa of 0.26 to 0.75 (P < .001). Conclusion: The KSRES significantly underestimates implant loosening. The proposed percentage-based system demonstrated excellent sensitivity, specificity, and interobserver reliability in determining tibial implant loosening in this patient population. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:2274 / 2278
页数:5
相关论文
共 50 条
  • [41] Tourniquet-free minimally invasive total knee arthroplasty is associated with early aseptic loosening
    Kunes, Jennifer A.
    El-Othmani, Mouhanad M.
    Lavelle, Matthew
    Santos, Walkania M.
    Geller, Jeffrey A.
    Shah, Roshan P.
    KNEE, 2024, 46 : 19 - 26
  • [42] PATIENT AND PROVIDER FACTORS ASSOCIATED WITH ASEPTIC LOOSENING FOLLOWING CEMENTED PRIMARY KNEE TOTAL ARTHROPLASTY
    Holub, A.
    Kr, S.
    Ray, B.
    Holy, C. E.
    Leopold, J.
    Daccach, J.
    Hoeffel, D.
    Coplan, P.
    VALUE IN HEALTH, 2021, 24 : S141 - S141
  • [43] Aseptic Tibial Debonding as a Cause of Early Failure in a Modern Total Knee Arthroplasty Design
    Arsoy, Diren
    Pagnano, Mark W.
    Lewallen, David G.
    Hanssen, Arlen D.
    Sierra, Rafael J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (01) : 94 - 101
  • [44] All-polyethylene Tibial Components in Modern Total Knee Arthroplasty
    Browne, James A.
    Sims, Susan E. Gall
    Giuseffi, Steven A.
    Trousdale, Robert T.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (09) : 527 - 535
  • [45] CONVERSION OF MGH HEMIARTHROPLASTY OF THE KNEE TO TOTAL KNEE ARTHROPLASTY USING CUSTOM TIBIAL COMPONENTS
    DRINKER, H
    POTTER, TA
    BIERBAUM, BE
    ORTHOPEDICS, 1980, 3 (02) : 124 - 130
  • [46] Metal-Backed Tibial Components Do Not Reduce Risk of Early Aseptic Loosening in Unicompartmental Knee Arthroplasty: A Systematic Review and Meta-Analysis
    Costa, Giuseppe Gianluca
    Lo Presti, Mirco
    Grassi, Alberto
    Agro, Giuseppe
    Cialdella, Sergio
    Mosca, Massimiliano
    Caravelli, Silvio
    Zaffagnini, Stefano
    JOURNAL OF KNEE SURGERY, 2020, 33 (02) : 180 - 189
  • [47] AXLE FRACTURE OF A KINEMATIC ROTATING HINGE TOTAL KNEE ARTHROPLASTY WITH ASSOCIATED TIBIAL COMPONENT LOOSENING
    RIES, MD
    DENNIS, DA
    CLAYTON, ML
    JOURNAL OF ORTHOPAEDIC RHEUMATOLOGY, 1994, 7 (02): : 122 - 126
  • [48] Significant differences in rates of aseptic loosening between two variations of a popular total knee arthroplasty design
    Michael Brown
    Rohan Ramasubbu
    Mark Jenkinson
    James Doonan
    Mark Blyth
    Bryn Jones
    International Orthopaedics, 2021, 45 : 2859 - 2867
  • [49] Risk factors for aseptic loosening in complex revision total knee arthroplasty using rotating hinge implants
    Levent, Ali
    Suero, Eduardo M.
    Gehrke, Thorsten
    Bakhtiari, Iman Godarzi
    Citak, Mustafa
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (01) : 125 - 132
  • [50] Outcomes of Salvage Endoprostheses in Revision Total Knee Arthroplasty for Infection and Aseptic Loosening: Experience of a Specialist Centre
    Matar, Hosam E.
    Bloch, Benjamin, V
    James, Peter J.
    KNEE, 2021, 29 : 547 - 556