A Novel Percentage-Based System for Determining Aseptic Loosening of Total Knee Arthroplasty Tibial Components

被引:20
|
作者
Chalmers, Brian P. [1 ]
Sculco, Peter K. [1 ]
Fehring, Keith A. [1 ]
Trousdale, Robert T. [1 ]
Taunton, Michael J. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, 200 First St SW, Rochester, MN 55905 USA
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 07期
关键词
tibial; loosening; aseptic; total knee arthroplasty; revision; RADIOLUCENT LINES; FAILING TODAY; CONTACT-STRESS; FAILURE; REVISION; STERILIZATION; REPLACEMENT; WEAR; POLYETHYLENE; MECHANISMS;
D O I
10.1016/j.arth.2017.02.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: There are limited data on evaluating the significance of radiolucent lines and aseptic loosening in total knee arthroplasty (TKA). We sought to compare the sensitivity, specificity, and reliability of the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System (KSRES) in detecting tibial component loosening compared to a novel percentage-based system (PBS). Methods: We retrospectively reviewed radiographs obtained from 48 patients within 6 months prior to revision TKA. The radiographs were randomized and four reviewers independently used the KSRES to categorize tibial implants as nonconcerning, clinical follow-up for progression, or loose as described by KSRES. For the PBS, the percent involvement of the tibial implant interface of any radiolucency at the bone-cement or cement-implant interface was determined. The higher percentage from either the anteroposterior or the lateral image was the final score. Components were categorized as nonconcerning (<= 10%), clinical follow-up for progression (11%-24%), or loose (>= 25%). We compared the sensitivity, specificity, and interobserver reliability using intraoperative assessment of implant fixation as the gold standard. Results: For the KSRES, the mean sensitivity for determining tibial loosening was 7.3% and mean specificity for determining a nonconcerning implant was 95.9%. The PBS significantly increased the sensitivity to 91.1% (P < .001) while maintaining a specificity of 87.9% (P = .2). Interobserver reliability significantly increased from a mean kappa of 0.26 to 0.75 (P < .001). Conclusion: The KSRES significantly underestimates implant loosening. The proposed percentage-based system demonstrated excellent sensitivity, specificity, and interobserver reliability in determining tibial implant loosening in this patient population. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:2274 / 2278
页数:5
相关论文
共 50 条
  • [21] FAILURE OF TOTAL KNEE ARTHROPLASTY DUE TO LOOSENING AND DEFORMATION OF TIBIAL COMPONENT
    DUCHEYNE, P
    KAGAN, A
    LACEY, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03): : 384 - 391
  • [22] Aseptic Loosening at the Tibia in Total Knee Arthroplasty: A Function of Cement Mantle Quality?
    Hampton, Chadwick B.
    Berliner, Zachary P.
    Nguyen, Joseph T.
    Mendez, Logan
    Smith, Sarah S.
    Joseph, Amethia D.
    Padgett, Douglas E.
    Rodriguez, Jose A.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : S190 - S196
  • [23] Isolated Versus Full Component Revision in Total Knee Arthroplasty for Aseptic Loosening
    Apinyankul, Rit
    Hwang, Katherine
    Segovia, Nicole Alexandriadria
    Amanatullah, Derek F.
    Huddleston, James I.
    Maloney, William J.
    Goodman, Stuart B.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (02): : 335 - 340
  • [24] Diagnostic value of bone scintigraphy for aseptic loosening after total knee arthroplasty
    Claassen, Leif
    Ettinger, Max
    Plaass, Christian
    Daniilidis, Kiriakos
    Calliess, Tilman
    Ezechieli, Marco
    TECHNOLOGY AND HEALTH CARE, 2014, 22 (05) : 767 - 773
  • [25] Comparison of the clinical and radiological outcomes between an isolated tibial component revision and total revision knee arthroplasty in aseptic loosening of an isolated tibial component
    Lee, Sung-Sahn
    Park, Jun-Seok
    Lee, Young Keun
    Moon, Young-Wan
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2021, 26 (03) : 435 - 440
  • [26] Poor outcomes of revision total knee arthroplasty in patients with septic loosening compared to patients with aseptic loosening
    Baek, Ji-Hoon
    Lee, Su Chan
    Jin, Hosun
    Kim, Jin-Woo
    Ahn, Hye Sun
    Nam, Chang Hyun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [27] Poor outcomes of revision total knee arthroplasty in patients with septic loosening compared to patients with aseptic loosening
    Ji-Hoon Baek
    Su Chan Lee
    Hosun Jin
    Jin-Woo Kim
    Hye Sun Ahn
    Chang Hyun Nam
    Journal of Orthopaedic Surgery and Research, 16
  • [28] Early aseptic loosening of primary total knee arthroplasty in patients with osteonecrosis of the knee: A case series
    Baek, Ji-Hoon
    Lee, Su Chan
    Ryu, Suengryol
    Ahn, Hye Sun
    Nam, Chang Hyun
    CLINICAL CASE REPORTS, 2022, 10 (12):
  • [29] Risk Factors for aseptic loosening after primary total knee arthroplasty with cemented knee implants
    Holy, Chantal E.
    Daccach, Juan
    Leopold, John
    Ray, Bidusee
    Coplan, Paul
    Hoeffel, Daniel
    Wright, John
    PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2020, 29 : 350 - 350
  • [30] Early aseptic loosening and inferior patient-reported outcomes of a cementless tibial baseplate in a modern total knee arthroplasty design
    Andronic, O.
    Yang, Y. H.
    Jones, C. W.
    Yates, P. J.
    BONE & JOINT JOURNAL, 2025, 107B (04): : 440 - 448