Clinical Influence of Micromorphological Structure of Dental Implant Bone Drills

被引:12
|
作者
Marenzi, Gaetano [1 ]
Sammartino, Jose Camilla [2 ]
Quaremba, Giuseppe [3 ]
Graziano, Vincenzo [4 ]
El Hassanin, Andrea [5 ]
Qorri, Med Erda [6 ]
Sammartino, Gilberto [1 ]
Iorio-Siciliano, Vincenzo [7 ]
机构
[1] Univ Federico II, Dept Neurosci Reprod & Odontostomatol Sci, Div Oral Surg, Via Pansini 5, Naples, Italy
[2] Univ L Spallanzani, Dept Biol & Biotechnol, Via Ferrata 9, Pavia, Italy
[3] Univ Naples Federico II, Dept Ind Engn, Via Claudio 21, Naples, Italy
[4] Univ Federico II, Dept Adv Biomed Sci, Via Pansini 5, Naples, Italy
[5] Univ Federico II, Dept Chem Mat & Prod Engn, Piazzale Tecchio 80, Naples, Italy
[6] Albanian Univ Str Durres, Div Oral & Maxillofacial Surg, Dept Dent, Tirana, Albania
[7] Univ Catanzaro Magna Graecia, Dept Periodontol, Viale Europa, Catanzaro, Italy
关键词
SURFACE-ROUGHNESS; HEAT-GENERATION; STAINLESS-STEEL; CORTICAL BONE; WEAR; OSTEOTOMY; STERILIZATION; DEFORMATION; BURS;
D O I
10.1155/2018/8143962
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background. Considerations about heat generation, wear, and corrosion due to some macrostructural bur components (e.g., cutting lips, rake angle, flute, and helix angle) have been widely reported. However, little is known about how the microstructural components of the implant drill surface can influence the implant drill lifetime and clinical performance. Aim. To investigate accurately the surface morphology of surgical bone drill, by means of multivariate and multidimensional statistical analysis, in order to assess roughness parameters able to predict the evolution of tribological phenomena linked to heat development, wear, and corrosion occurring in clinical use. Materials and Methods. The surfaces of implant drills approximately 2.0mm in diameter made by five manufacturers were examined by means of confocal microscope with white light laser interferometry, obtaining several surface roughness parameters. Statistical multivariate analysis based on discriminant analysis showed, for each cut-off, the parameters which discriminate the manufacturers. Results. The microstructural parameters used by discriminant analysis evidenced several differences in terms of drill surface roughness between the five manufacturers. Conclusions. The observed surface roughness difference of drills is able to predict a different durability and clinical performance especially in heat generation and wear onset.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Influence of dental implant clinical experience on the accuracy of robot-assisted immediate implant placement: an in vitro study
    Wang, Yunxiao
    Wang, Yulan
    Yu, Shimin
    Han, Litian
    Feng, Yi
    Miron, Richard J.
    Yan, Qi
    Zhang, Yufeng
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (09)
  • [42] Influence of Crown-Implant Ratio and Implant Inclination on Marginal Bone Loss around Dental Implants Supporting Single Crowns in the Posterior Region: A Retrospective Clinical Study
    Rahim, Maha Abdul
    Khan, Kashmala
    Chrcanovic, Bruno Ramos
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (09)
  • [43] Thermal Variation During Osteotomy With Different Dental Implant Drills: A Standardized Study in Bovine Ribs
    Hochscheidt, Celso Joao
    Shimizu, Roberto Hideo
    Andrighetto, Augusto Ricardo
    Moura, Luis Mauro
    Golin, Alexsander Luiz
    Hochscheidt, Regina Celia
    IMPLANT DENTISTRY, 2017, 26 (01) : 73 - 79
  • [44] Implant placement with an autonomous dental implant robot: A clinical report
    Li, Zhiwen
    Xie, Rui
    Bai, Shizhu
    Zhao, Yimin
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02): : 340 - 345
  • [45] Influence of Bioactive Material Coating of Ti Dental Implant Surfaces on Early Healing and Osseointegration of Bone
    Yeo, In-Sung
    Min, Seung-Ki
    An, Youngbai
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 57 (06) : 1717 - 1720
  • [46] Influence of Laser Irradiation to the Structure of Dental Implant Surface during Professional Oral Hygiene
    Tarasenko, S. V.
    Repina, S. I.
    Garipov, R. D.
    Morozova, E. A.
    INTERNATIONAL CONFERENCE LASER OPTICS 2020 (ICLO 2020), 2020,
  • [47] BONE CALCIFICATION ON THE HYDROXYAPATITE DENTAL IMPLANT AND THE BONE-HYDROXYAPATITE INTERFACE
    OGISO, M
    TABATA, T
    ICHIJO, T
    BORGESE, D
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 1992, 2 (2-3) : 137 - 148
  • [48] The influence of tobacco on early dental implant failure
    Sverzut, Alexander Tadeu
    Vitti Stabile, Glaykon Alex
    de Moraes, Marcio
    Mazzonetto, Renato
    Fernandes Moreira, Roger William
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (05) : 1004 - 1009
  • [49] Clinical Applications of Recombinant Human Bone Morphogenetic Protein-2 for Bone Augmentation Before Dental Implant Placement
    Misch, Craig
    Wang, Hom-Lay
    CLINICAL ADVANCES IN PERIODONTICS, 2011, 1 (02): : 118 - 131
  • [50] The study of bone density assessment on dental implant sites
    Park, Su-Won
    Jang, Soo-Mi
    Choi, Byoung-Hwan
    Son, Han-Na
    Park, Bong-Chan
    Kim, Chang-Hwan
    Son, Jang-Ho
    Sung, Iel-Yong
    Lee, Ji-Ho
    Cho, Yeong-Cheol
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2010, 36 (05) : 417 - 422