Clinical Influence of Micromorphological Structure of Dental Implant Bone Drills

被引:12
|
作者
Marenzi, Gaetano [1 ]
Sammartino, Jose Camilla [2 ]
Quaremba, Giuseppe [3 ]
Graziano, Vincenzo [4 ]
El Hassanin, Andrea [5 ]
Qorri, Med Erda [6 ]
Sammartino, Gilberto [1 ]
Iorio-Siciliano, Vincenzo [7 ]
机构
[1] Univ Federico II, Dept Neurosci Reprod & Odontostomatol Sci, Div Oral Surg, Via Pansini 5, Naples, Italy
[2] Univ L Spallanzani, Dept Biol & Biotechnol, Via Ferrata 9, Pavia, Italy
[3] Univ Naples Federico II, Dept Ind Engn, Via Claudio 21, Naples, Italy
[4] Univ Federico II, Dept Adv Biomed Sci, Via Pansini 5, Naples, Italy
[5] Univ Federico II, Dept Chem Mat & Prod Engn, Piazzale Tecchio 80, Naples, Italy
[6] Albanian Univ Str Durres, Div Oral & Maxillofacial Surg, Dept Dent, Tirana, Albania
[7] Univ Catanzaro Magna Graecia, Dept Periodontol, Viale Europa, Catanzaro, Italy
关键词
SURFACE-ROUGHNESS; HEAT-GENERATION; STAINLESS-STEEL; CORTICAL BONE; WEAR; OSTEOTOMY; STERILIZATION; DEFORMATION; BURS;
D O I
10.1155/2018/8143962
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background. Considerations about heat generation, wear, and corrosion due to some macrostructural bur components (e.g., cutting lips, rake angle, flute, and helix angle) have been widely reported. However, little is known about how the microstructural components of the implant drill surface can influence the implant drill lifetime and clinical performance. Aim. To investigate accurately the surface morphology of surgical bone drill, by means of multivariate and multidimensional statistical analysis, in order to assess roughness parameters able to predict the evolution of tribological phenomena linked to heat development, wear, and corrosion occurring in clinical use. Materials and Methods. The surfaces of implant drills approximately 2.0mm in diameter made by five manufacturers were examined by means of confocal microscope with white light laser interferometry, obtaining several surface roughness parameters. Statistical multivariate analysis based on discriminant analysis showed, for each cut-off, the parameters which discriminate the manufacturers. Results. The microstructural parameters used by discriminant analysis evidenced several differences in terms of drill surface roughness between the five manufacturers. Conclusions. The observed surface roughness difference of drills is able to predict a different durability and clinical performance especially in heat generation and wear onset.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison of the Bone Harvesting Capacity of an Intraoral Bone Harvesting Device and Three Different Implant Drills
    Lim, Hyun-Chang
    Ha, Kyung-In
    Hong, Ji-Youn
    Han, Ji-Young
    Shin, Seung-Il
    Shin, Seung-Yun
    Herr, Yeek
    Chung, Jong-Hyuk
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [22] The Effect of Dental Implant Drills Materials on Heat Generation in Osteotomy Sites: A Systematic Review
    Chakraborty, Shreyasi
    Moufti, Mohammad-Adel
    Kheder, Waad
    EUROPEAN JOURNAL OF DENTISTRY, 2024, 18 (01) : 65 - 72
  • [23] Influence of Multiple Used Implant Drills on Their Cutting Performance and Fracture Resistance
    Alevizakos, Vasilios
    Mosch, Richard
    von See, Constantin
    MATERIALS, 2023, 16 (15)
  • [24] The influence of dental experience on a dental implant navigation system
    Ting-Mao Sun
    Huey-Er Lee
    Ting-Hsun Lan
    BMC Oral Health, 19
  • [25] The influence of dental experience on a dental implant navigation system
    Sun, Ting-Mao
    Lee, Huey-Er
    Lan, Ting-Hsun
    BMC ORAL HEALTH, 2019, 19 (01)
  • [26] Clinical evaluation of two dental implant macrostructures on peri-implant bone loss: a comparative, retrospective study
    Dagorne, Cecile
    Malet, Jacques
    Bizouard, Geoffray
    Mora, Francis
    Range, Helene
    Bouchard, Philippe
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (03) : 307 - 313
  • [27] Optimum Degree of Bone-Implant Contact in Bone Remodelling Induced by Dental Implant
    Lian, Z. Q.
    Guan, H.
    Loo, Y. C.
    PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14
  • [28] Effect of bone-implant contact percentage on bone remodeling surrounding a dental implant
    Lian, Zhiqiang
    Guan, Hong
    2010 International Conference on Biomedical Engineering and Computer Science, ICBECS 2010, 2010,
  • [29] A Parametric Study on a Dental Implant Geometry Influence on Bone Remodelling through a Numerical Algorithm
    Santonocito, Dario
    Nicita, Fabiana
    Risitano, Giacomo
    PROSTHESIS, 2021, 3 (02): : 157 - 172
  • [30] Influence of Bone and Dental Implant Parameters on Stress Distribution in the Mandible: A Finite Element Study
    Guan, Hong
    van Staden, Rudi
    Loo, Yew-Chaye
    Johnson, Newell
    Ivanovski, Saso
    Meredith, Neil
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 866 - 876