ANALYTICAL VALIDATION METHOD FOR THE DETERMINATION OF SULFONYLUREA HERBICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND HPLC WITH DIODE-ARRAY DETECTION

被引:0
|
作者
Grahovac, N. [1 ]
Suturovic, Z.
Kondic-Spika, A. [1 ]
Sekulic, P.
Lazic, S.
Sunjka, D.
Jaksic, S. [1 ]
机构
[1] Inst Field & Vegetables Crops, Novi Sad 21000, Serbia
关键词
sulfonylurea herbicides; determination; surface water; HPLC-DAD; SOILS;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pesticides having different structures and biological activities are widely used for agricultural and non-agricultural purposes. Due to their widespread use, pesticides need to be determined in various environmental matrices. A wide range of analytical techniques have been developed in order to identify the organic contaminants often present at trace levels in environmental samples. The aim of this work was to develop a reliable, rapid, robust and cost-effective method for the determination of five sulfonylurea herbicides (nicosulfuron, oxasulfuron, tribenuron methyl, triasulfuron and tritosulfuron) in spiked river water samples. The samples were diluted with 0.5% acetic acid (1:1) and purified by solid-phase extraction (SPE) on Oasis MAX cartridges. After the cartridges were sequentially washed with water, methanol, ethyl acetate, and acetonitrile, they were eluted with 0.1% formic acid in acetonitrile. Elutes were evaporated to dryness and reconstituted in acetonitrile. The purified extracts were analyzed by reversed-phase high-performance liquid chromatography with diode-array detection (HPLC-DAD) system. The best separation was achieved on a Zorbax Eclipse XDB-C-18 (50mm x 4.6mm x 1.8 mu m) analytical column with gradient elution at a flow rate of 1 mL/min. The analyte was monitored at 230 nm. The linearity of calibration curve within the tested concentration range exhibited correlation coefficients (r(2)) higher than 0.998. The accuracy of the method was acceptable since the average recoveries measured at two fortification levels were in the range of 92.5-97.5% (n=3). The precision of the developed procedure expressed as the relative standard deviations (RSDs) were lower than 4.76% in all cases. The repeatability of the retention time and peak area was checked by injecting standard solution ten times. The relative standard deviation of the retention time and the peak area was found to be less than 0.2% and 0.6%, respectively. The method was also validated by analyzing freshly spiked river water samples. The proposed analytical method might be successfully applied in monitoring of sulfonylurea herbicides (nicosulfuron, oxasulfuron, tribenuron methyl, triasulfuron and tritosulfuron) in surface water and groundwater samples.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [41] THE DEVELOPMENT AND VALIDATION OF A SOLID-PHASE EXTRACTION HPLC METHOD FOR THE DETERMINATION OF AFLATOXINS IN GROUNDNUT MEAL
    ROCH, OG
    BLUNDEN, G
    COKER, RD
    NAWAZ, S
    CHROMATOGRAPHIA, 1992, 33 (5-6) : 208 - 212
  • [42] Development of a solid-phase extraction method followed by HPLC-UV detection for the determination of phenols in water
    Opeolu, B. O.
    Fatoki, O. S.
    Odendaal, J.
    INTERNATIONAL JOURNAL OF THE PHYSICAL SCIENCES, 2010, 5 (05): : 576 - 581
  • [43] Analysis of etorphine in postmortem samples by HPLC with UV diode-array detection
    Elliott, SP
    Hale, KA
    FORENSIC SCIENCE INTERNATIONAL, 1999, 101 (01) : 9 - 16
  • [44] ISOLATION AND RECOVERY FROM WATER OF SELECTED CHLOROPHENOXY ACID HERBICIDES AND SIMILAR WEAK ACID HERBICIDES BY SOLID-PHASE EXTRACTION HPLC AND PHOTODIODE ARRAY DETECTION
    LOCONTO, PR
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (07): : 1297 - 1314
  • [45] Determination of orphenadrine plasma levels using HPLC with diode array detection and a novel solid-phase extraction procedure in psychiatric patients
    Saracino, M. A.
    Petio, C.
    Vitali, M.
    Franchini, L.
    Raggi, M. A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (03) : 501 - 506
  • [46] ASSESSEMENT OF TRIAZINE HERBICIDES CONTENT IN HONEY SAMPLES BY SOLID-PHASE EXTRACTION AND HPLC ANALYSIS
    Dragus, Andreea
    Beldean-Galea, Mihail Simion
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2015, 60 (02): : 117 - 124
  • [47] On-line solid-phase extraction coupled to supercritical fluid chromatography with diode array detection for the determination of pesticides in water
    Bernal, JL
    Jimenez, JJ
    Rivera, JM
    Toribio, L
    delNozal, MJ
    JOURNAL OF CHROMATOGRAPHY A, 1996, 754 (1-2) : 145 - 157
  • [48] Determination of aldicarb, carbofuran and some of their main metabolites in groundwater by application of micellar electrokinetic capillary chromatography with diode-array detection and solid-phase extraction
    Arráez-Román, D
    Segura-Carretero, A
    Cruces-Blanco, C
    Fernández-Gutiérrez, A
    PEST MANAGEMENT SCIENCE, 2004, 60 (07) : 675 - 679
  • [49] Selective trace analysis of sulfonylurea herbicides in water and soil samples based on solid-phase extraction using a molecularly imprinted polymer
    Zhu, QZ
    DeGelmann, P
    Niessner, R
    Knopp, D
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (24) : 5411 - 5420
  • [50] OPTIMIZATION OF THE SEPARATION, ISOLATION AND RECOVERY OF SELECTED PESTICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND HPLC PHOTODIODE-ARRAY DETECTION
    PARRILLA, P
    MARTINEZVIDAL, JL
    FERNANDEZALBA, AR
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (18): : 4019 - 4029