ANALYTICAL VALIDATION METHOD FOR THE DETERMINATION OF SULFONYLUREA HERBICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND HPLC WITH DIODE-ARRAY DETECTION

被引:0
|
作者
Grahovac, N. [1 ]
Suturovic, Z.
Kondic-Spika, A. [1 ]
Sekulic, P.
Lazic, S.
Sunjka, D.
Jaksic, S. [1 ]
机构
[1] Inst Field & Vegetables Crops, Novi Sad 21000, Serbia
关键词
sulfonylurea herbicides; determination; surface water; HPLC-DAD; SOILS;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pesticides having different structures and biological activities are widely used for agricultural and non-agricultural purposes. Due to their widespread use, pesticides need to be determined in various environmental matrices. A wide range of analytical techniques have been developed in order to identify the organic contaminants often present at trace levels in environmental samples. The aim of this work was to develop a reliable, rapid, robust and cost-effective method for the determination of five sulfonylurea herbicides (nicosulfuron, oxasulfuron, tribenuron methyl, triasulfuron and tritosulfuron) in spiked river water samples. The samples were diluted with 0.5% acetic acid (1:1) and purified by solid-phase extraction (SPE) on Oasis MAX cartridges. After the cartridges were sequentially washed with water, methanol, ethyl acetate, and acetonitrile, they were eluted with 0.1% formic acid in acetonitrile. Elutes were evaporated to dryness and reconstituted in acetonitrile. The purified extracts were analyzed by reversed-phase high-performance liquid chromatography with diode-array detection (HPLC-DAD) system. The best separation was achieved on a Zorbax Eclipse XDB-C-18 (50mm x 4.6mm x 1.8 mu m) analytical column with gradient elution at a flow rate of 1 mL/min. The analyte was monitored at 230 nm. The linearity of calibration curve within the tested concentration range exhibited correlation coefficients (r(2)) higher than 0.998. The accuracy of the method was acceptable since the average recoveries measured at two fortification levels were in the range of 92.5-97.5% (n=3). The precision of the developed procedure expressed as the relative standard deviations (RSDs) were lower than 4.76% in all cases. The repeatability of the retention time and peak area was checked by injecting standard solution ten times. The relative standard deviation of the retention time and the peak area was found to be less than 0.2% and 0.6%, respectively. The method was also validated by analyzing freshly spiked river water samples. The proposed analytical method might be successfully applied in monitoring of sulfonylurea herbicides (nicosulfuron, oxasulfuron, tribenuron methyl, triasulfuron and tritosulfuron) in surface water and groundwater samples.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [31] Application of Solid-Phase Extraction and Planar Chromatography with Diode-Array Detection to the Qualitative and Quantitative Analysis of Dyes in Beverages
    Tomasz Tuzimski
    Arkadiusz Woźniak
    JPC – Journal of Planar Chromatography – Modern TLC, 2008, 21 : 89 - 96
  • [32] Determination of caffeine as a tracer of sewage effluent in natural waters by on-line solid-phase extraction and liquid chromatography with diode-array detection
    Chen, ZL
    Pavelic, P
    Dillon, P
    Naidu, R
    WATER RESEARCH, 2002, 36 (19) : 4830 - 4838
  • [33] Application of solid-phase extraction and planar chromatography with diode-array detection to the qualitative and quantitative analysis of dyes in beverages
    Tuzimski, Tomasz
    Wozniak, Arkadiusz
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2008, 21 (02) : 89 - 96
  • [34] Trace analysis of sulfonylurea herbicides in water samples by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Fenoll, Jose
    Hellin, Pilar
    Sabater, Paula
    Flores, Pilar
    Navarro, Simon
    TALANTA, 2012, 101 : 273 - 282
  • [35] TRACE ENRICHMENT AND HPLC ANALYSIS OF POLYCYCLIC AROMATIC-HYDROCARBONS IN ENVIRONMENTAL-SAMPLES, USING SOLID-PHASE EXTRACTION IN CONNECTION WITH UV/VIS DIODE-ARRAY AND FLUORESCENCE DETECTION
    KICINSKI, HG
    ADAMEK, S
    KETTRUP, A
    CHROMATOGRAPHIA, 1989, 28 (3-4) : 203 - 208
  • [36] Determination of gatifloxacin in semen by HPLC with diode-array and fluorescence detection
    Salazar-Cavazos, M. L.
    Gonzalez, L. Y. Colunga
    de Lerma, G. Gallegos
    de Torres, N. Waksman
    CHROMATOGRAPHIA, 2006, 63 (11-12) : 605 - 608
  • [37] Determination of Gatifloxacin in Semen by HPLC with Diode-Array and Fluorescence Detection
    M. L. Salazar Cavazos
    L. Y. Colunga González
    G. Gallegos de Lerma
    N. Waksman de Torres
    Chromatographia, 2006, 63 : 605 - 608
  • [38] Rapid determination of pahs in drinking water samples using solid-phase extraction and HPLC with programmed fluorescence detection
    KayaliSayadi, MN
    RubioBarroso, S
    BeceiroRoldan, C
    PoloDiez, LM
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (19) : 3135 - 3146
  • [39] Determination of naphthalenesulphonates in water by on-line ion-pair solid-phase extraction and ion-pair liquid chromatography with diode-array UV detection
    El Harrak, R
    Calull, M
    Marce, RM
    Borrull, F
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1998, 69 (04) : 295 - 305
  • [40] A new method for the determination of selected PAHs in coffee brew samples by HPLC with fluorimetric detection and solid-phase extraction
    Kayali-Sayadi, MN
    Rubio-Barroso, S
    Cuesta-Jimenez, MP
    Polo-Díez, LM
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (04) : 615 - 627