Risk Factors for Infections Involving Cardiac Implanted Electronic Devices

被引:116
|
作者
Birnie, David H. [1 ]
Wang, Jia [2 ]
Alings, Marco [3 ]
Philippon, Francois [4 ]
Parkash, Ratika [5 ]
Manlucu, Jaimie [6 ]
Angaran, Paul [7 ]
Rinne, Claus [8 ]
Coutu, Benoit [9 ]
Low, R. Aaron [10 ]
Essebag, Vidal [11 ]
Morillo, Carlos [12 ]
Redfearn, Damian [13 ]
Toal, Satish [14 ]
Becker, Giuliano [15 ]
Degrace, Michel [16 ]
Thibault, Bernard [17 ]
Crystal, Eugene [18 ]
Tung, Stanley [19 ]
LeMaitre, John [20 ]
Sultan, Omar [21 ]
Bennett, Matthew [21 ,22 ]
Bashir, Jamil [23 ]
Ayala-Paredes, Felix [24 ]
Gervais, Philippe [4 ]
Rioux, Leon [25 ]
Hemels, Martin E. W. [26 ,27 ]
Bouwels, Leon H. R. [28 ]
Exner, Derek V. [12 ]
Dorian, Paul [7 ]
Connolly, Stuart J. [2 ]
Longtin, Yves [29 ]
Krahn, Andrew D. [23 ]
机构
[1] Univ Ottawa, Inst Heart, Ottawa, ON, Canada
[2] McMaster Univ, Hamilton Hlth Sci, Populat Hlth Res Inst, Hamilton, ON, Canada
[3] Amphia Ziekenhuis & Working Grp Cardiovasc Res Ne, Breda, Netherlands
[4] Laval Univ, Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
[5] Queen Elizabeth 2 Hlth Sci Ctr, Halifax, NS, Canada
[6] Western Univ, London Hlth Sci, Lawson Hlth Res Inst, London, ON, Canada
[7] Univ Toronto, St Michael Hosp, Div Cardiol, Dept Med, Toronto, ON, Canada
[8] St Marys Gen Hosp, Kitchener, ON, Canada
[9] Univ Montreal, Ctr Hosp Univ Montreal, Montreal, PQ, Canada
[10] Chinook Reg Hosp, Lethbridge, AB, Canada
[11] McGill Univ, Ctr Hlth, Montreal, PQ, Canada
[12] Univ Calgary, Libin Cardiovasc Inst Alberta, Calgary, AB, Canada
[13] Queens Univ, Kingston Gen Hosp, Kingston, ON, Canada
[14] Horizon Hlth Network, St John, NB, Canada
[15] Univ Montreal, Hop Sacre Coeur Montreal, Montreal, PQ, Canada
[16] Hotel Dieu Levis, Levis, PQ, Canada
[17] Montreal Heart Inst, Montreal, PQ, Canada
[18] Sunnybrook Hlth Sci Ctr, Toronto, ON, Canada
[19] Univ British Columbia, St Pauls Hosp, Vancouver, BC, Canada
[20] Royal Columbian Hosp, New Westminster, BC, Canada
[21] Saskatchewan Hlth Author, Regina Gen Hosp, Regina, SK, Canada
[22] Univ British Columbia, Vancouver Gen Hosp, Vancouver, BC, Canada
[23] Univ British Columbia, Vancouver, BC, Canada
[24] Ctr Hosp Univ Sherbrooke, Sherbrooke, PQ, Canada
[25] Ctr Sante & Serv Sociaux Rimouski Neigette, Rimouski, PQ, Canada
[26] Rijnstate Hosp, Arnhem, Netherlands
[27] Radboud Univ Nijmegen, Med Ctr, Nijmegen, Netherlands
[28] Canisius Wilhelmina Ziekenhuis, Nijmegen, Netherlands
[29] McGill Univ, Jewish Gen Hosp Sir Mortimer B Davis, Montreal, PQ, Canada
关键词
antibiotics; cardiac implantable electronic device; implantable cardioverter defibrillator; infection; pacemaker; MANAGEMENT; MORTALITY; PREVENTION; PACEMAKER; TRIAL; TIME;
D O I
10.1016/j.jacc.2019.09.060
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Cardiac implantable electronic device infection is a major complication that usually requires device removal. PADIT (Prevention of Arrhythmia Device Infection Trial) was a large cluster crossover trial of conventional versus incremental antibiotics. OBJECTIVES This study sought to investigate independent predictors of device infection in PADIT and develop a novel infection risk score. METHODS In brief, over 4 6-month periods, 28 centers used either conventional or incremental prophylactic antibiotic treatment in all patients. The primary outcome was hospitalization for device infection within 1 year (blinded endpoint adjudication). Multivariable logistic prediction modeling was used to identify the independent predictors and develop a risk score for device infection. The prediction models were internally validated with bootstrap methods. RESULTS Device procedures were performed in 19,603 patients, and hospitalization for infection occurred in 177 (0.90%) within 1 year of follow-up. The final prediction model identified 5 independent predictors of device infection (prior procedures [P], age [A], depressed renal function [D], immunocompromised [I], and procedure type [T]) with an optimism-corrected C-statistic of 0.704 (95% confidence interval: 0.660 to 0.744). A PADIT risk score ranging from 0 to 15 points classified patients into low (0 to 4), intermediate (5 to 6) and high (>= 7) risk groups with rates of hospitalization for infection of 0.51%, 1.42%, and 3.41%, respectively. CONCLUSIONS This study identified 5 independent predictors of device infection and developed a novel infection risk score in the largest cardiac implantable electronic device trial to date, warranting validation in an independent cohort. The 5 independent predictors in the PADIT score are readily adopted into clinical practice. (C) 2019 Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:2845 / 2854
页数:10
相关论文
共 50 条
  • [21] AF detected on implanted cardiac implantable electronic devices: Is there a threshold for thromboembolic risk? topical collection on arrhythmia
    Baibars M.
    Kanjwal K.
    Marine J.E.
    Current Treatment Options in Cardiovascular Medicine, 2014, 16 (3)
  • [22] Annual atrial tachyarrhythmia burden determined by device interrogation in patients with cardiac implanted electronic devices is associated with a risk of ischaemic stroke independent of known risk factors
    Wang, Szu-Heng
    Kang, Yu-Chuan
    Wang, Chun-Chieh
    Wen, Ming-Shien
    Hung, Kuo-Chun
    Wang, Chao-Yung
    Chen, Tien-Hsing
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (05) : 840 - 846
  • [23] Predictive factors of lead failure in patients implanted with cardiac devices
    Aizawa, Yoshiyasu
    Negishi, Masachika
    Kashimura, Shin
    Nakajima, Kazuaki
    Kunitomi, Akira
    Katsumata, Yoshinori
    Nishiyama, Takahiko
    Kimura, Takehiro
    Nishiyama, Nobuhiro
    Fukumoto, Kotaro
    Tanimoto, Yoko
    Kohsaka, Shun
    Takatsuki, Seiji
    Fukuda, Keiichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 199 : 277 - 281
  • [24] Reducing Risk During Endoscopy in Patients with Implanted Electronic Devices
    Petersen, Bret T.
    TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY, 2007, 9 (04) : 208 - 212
  • [25] Cardiac implanted electronic devices and MRI safety in 2018—the state of play
    Ryan Mark Shulman
    Ben Hunt
    European Radiology, 2018, 28 : 4062 - 4065
  • [26] Risk factors for the development of incident atrial fibrillation in patients with cardiac implantable electronic devices
    Miyazawa, Kazuo
    Kondo, Yusuke
    Nakano, Miyo
    Asuncion Esteve-Pastor, Maria
    Miguel Rivera-Caravaca, Jose
    Senoo, Keitaro
    Kobayashi, Yoshio
    Lip, Gregory Y. H.
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2018, 52 : 54 - 59
  • [27] Infectious complications in patients with cardiac implantable electronic devices: risk factors, prevention, and prognosis
    Polewczyk, Anna
    Jachec, Wojciech
    Polewczyk, Aneta M.
    Tomasik, Andrzej
    Janion, Marianna
    Kutarski, Andrzej
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2017, 127 (09): : 597 - 607
  • [28] Risk factors of thrombotic formation on leads in children with transvenous cardiac implantable electronic devices
    Verchenko, E. G.
    Dolinskaya, D. A.
    Bereznitskaya, V. V.
    Kalinin, L. A.
    Termosesov, S. A.
    Garipov, R. S. H.
    Shkolnikova, M. A.
    EUROPEAN HEART JOURNAL, 2017, 38 : 365 - 365
  • [29] Are implanted electronic devices hackable?
    Alexander, Bryce
    Haseeb, Sohaib
    Baranchuk, Adrian
    TRENDS IN CARDIOVASCULAR MEDICINE, 2019, 29 (08) : 476 - 480
  • [30] Cardiac implantable electronic devices and bloodstream infections: management and outcomes
    Ozkartal, Tardu
    Demarchi, Andrea
    Conte, Giulio
    Pongan, Damiano
    Klersy, Catherine
    Caputo, Maria Luce
    Bergonti, Marco
    Bernasconi, Enos
    Gaia, Valeria
    Granger, Christopher B.
    Auricchio, Angelo