Infectious complications in patients with cardiac implantable electronic devices: risk factors, prevention, and prognosis

被引:21
|
作者
Polewczyk, Anna [1 ,2 ]
Jachec, Wojciech [3 ]
Polewczyk, Aneta M. [4 ]
Tomasik, Andrzej [3 ]
Janion, Marianna [1 ,2 ]
Kutarski, Andrzej [5 ]
机构
[1] Jan Kochanowski Univ Kielce, Fac Med & Hlth Sci, Kielce, Poland
[2] Swietokrzyskie Cardiol Ctr, Dept Cardiol 2, Kielce, Poland
[3] Med Univ Silesia, Sch Med, Div Dent Zabrze, Dept Cardiol 2, Zabrze, Poland
[4] Dist Hosp, Dept Pediat 1, Kielce, Poland
[5] Med Univ Lublin, Dept Cardiol, Lublin, Poland
关键词
cardiac device infections; lead-related infective endocarditis; long-term survival; pocket infections; risk factors; STAPHYLOCOCCUS-AUREUS BACTEREMIA; CARDIOVERTER-DEFIBRILLATORS; PACEMAKERS; LEADS;
D O I
10.20452/pamw.4065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
INTRODUCTION Cardiac implantable electronic device (CIED) infections still constitute a significant challenge. The knowledge of risk factors for CIED infections is crucial for preventing infections and reducing mortality rates. OBJECTIVES The aim of this study was to assess the risk factors and long-term survival of patients with CIED infections. PATIENTS AND METHODS We analyzed the clinical data of 1837 patients (including xx [40.9%] patients with CIED infections), who underwent transvenous lead extraction at a single institution between 2006 and 2015. We compared the clinical and procedure-related factors for all types of CIED infections: isolated pocket infection (IPI), isolated lead-related infective endocarditis (ILRIE), and lead-related infective endocarditis with coexisting pocket infection (LRIE + PI). We also analyzed long-term survival rates. RESULTS The development of IPI and LRIE + PI depended mainly on age, male sex, number of leads, presence of implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D), and the number of previous procedures. The factors that determined ILRIE included chronic renal failure (CRF), ICD/CRT-D, lead loops, and intracardiac lead abrasion. Chronic anticoagulation and antiplatelet treatment protected against the development of infection. Long-term survival was significantly related to age, heart failure, diabetes mellitus, CRF, malignancy, and chronic atrial fibrillation. CONCLUSIONS The development of all types of CIED infection was associated mainly with procedure-related factors, while long-term mortality was dependent on clinical factors. The dissimilarity of factors affecting the development of IPI and ILRIE confirms that there are 2 variants of CIED infection. The protective effects of chronic anticoagulation and antiplatelet treatment should prompt us to consider such therapy in the prevention of CIED infection.
引用
收藏
页码:597 / 607
页数:11
相关论文
共 50 条
  • [1] Lead complications after cardiac surgery in patients with cardiac implantable electronic devices
    Frausing, Maria Hee Jung Park
    Nielsen, Jens Cosedis
    Johansen, Jens Brock
    Jorgensen, Ole Dan
    Kristensen, Jens
    Olsen, Thomas
    Gerdes, Christian
    Kronborg, Mads Brix
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 62 (02)
  • [2] Risk factors for the development of incident atrial fibrillation in patients with cardiac implantable electronic devices
    Miyazawa, Kazuo
    Kondo, Yusuke
    Nakano, Miyo
    Asuncion Esteve-Pastor, Maria
    Miguel Rivera-Caravaca, Jose
    Senoo, Keitaro
    Kobayashi, Yoshio
    Lip, Gregory Y. H.
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2018, 52 : 54 - 59
  • [3] Discussing the Prognosis and Complications of Transvenous Lead Extraction in Patients With Cardiac Implantable Electronic Devices (CIED): A Systematic Review
    Salib, Korlos
    Dardari, Lana
    Taha, Maher
    Dahat, Purva
    Toriola, Stacy
    Satnarine, Travis
    Zohara, Zareen
    Adelekun, Ademiniyi
    Seffah, Kofi D.
    Khan, Safeera
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [4] Influence of the type of pathogen on the clinical course of infectious complications related to cardiac implantable electronic devices
    Polewczyk, Anna
    Jachec, Wojciech
    Segreti, Luca
    Bongiorni, Maria Grazia
    Kutarski, Andrzej
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [5] Influence of the type of pathogen on the clinical course of infectious complications related to cardiac implantable electronic devices
    Anna Polewczyk
    Wojciech Jacheć
    Luca Segreti
    Maria Grazia Bongiorni
    Andrzej Kutarski
    Scientific Reports, 11
  • [6] Cardiac MRI for Patients With Cardiac Implantable Electronic Devices
    Stojanovska, Jadranka
    Runge, Mason
    Mahani, Maryam Ghadimi
    Cronin, Paul P.
    Sayyouh, Mohamed
    Bogun, Frank
    Ibrahim, El-Sayed H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 374 - 381
  • [7] CARDIAC IMPLANTABLE ELECTRONIC DEVICES COMPLICATIONS - A SINGLE CENTRE EXPERIENCE
    Ryan, N.
    Mahon, N.
    Walsh, K.
    O'Neill, J.
    Keelan, E.
    Keelan, P.
    Galvin, J.
    Kuan, K.
    HEART, 2015, 101 : A6 - A7
  • [8] Critical appraisal of cardiac implantable electronic devices: complications and management
    Padeletti, Luigi
    Mascioli, Giosue
    Perini, Alessandro Paoletti
    Grifoni, Gino
    Perrotta, Laura
    Marchese, Procolo
    Bontempi, Luca
    Curnis, Antonio
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2011, 4 : 157 - 167
  • [9] MRI of Patients with Cardiac Implantable Electronic Devices
    Martinez, Jessica A.
    Ennis, Daniel B.
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2019, 12 (07)
  • [10] MRI in patients with cardiac implantable electronic devices
    Cronin, Edmond M.
    Mahon, Niall
    Wilkoff, Bruce L.
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (02) : 139 - 146