Simultaneous determination of bisphenol A and estrogens in hair samples by liquid chromatography-electrospray tandem mass spectrometry

被引:33
|
作者
Lee, Chaelin [1 ,2 ]
Kim, Chong Hyeak [1 ]
Kim, Sunghwan [2 ]
Cho, Sung-Hee [1 ]
机构
[1] KRICT, Ctr Chem Anal, Daejeon 305600, South Korea
[2] Kyungpook Natl Univ, Dept Chem, Daegu 41566, South Korea
关键词
Bisphenol A; Estrogens; Hair; Liquid chromatography; Mass spectrometry; HUMAN URINE; ENVIRONMENTAL ESTROGENS; ENDOCRINE; QUANTIFICATION; VALIDATION; EXPOSURE; DERIVATIZATION; ASSOCIATION; DANSYLATION; IONIZATION;
D O I
10.1016/j.jchromb.2017.05.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bisphenol A (BPA), an endocrine disrupter, is widely used to make chemicals for polycarbonate, plastics, beverage containers, epoxy resins, and cash register receipts. BPA is one of the known xenoestrogens, which have weak estrogenic activity and cause obesity, diabetes, breast cancer, and reproductive disorders. Even though the concentration level of metabolomes in hair is usually lower than that in urine and blood, there are several reasons why we chose to use hair samples. First, the sampling procedure of hairs is simple. Second, it is also easy to preserve the sample for long term and track the drug-exposure record of a given sample. Third, deformation and contamination of samples rarely occur. In this study, an improved analytical method to determine the levels of BPA and estrogens in hair samples was developed by liquid chromatography-electrospray tandem mass spectrometry (LC-ESI/MS/MS). Hair samples were extracted by an Oasis HLB extraction cartridge after incubation with 1 N HCl and derivatized with dansyl chloride to increase sensitivity. BPA and estrogens (estrone, 17 beta-estradiol, and estriol) were separated using Shiseido CAPCELL PAK C-18 column (2.0 x 100 mm, 3 mu m) and a mobile phase consisting of 10 mM ammonium acetate in water and acetonitrile with a gradient program at a flow rate of 0.3 mL/min and were monitored with electrospray tandem mass spectrometry (ESI MS/MS). The linearity of this method was over 0.995. The limits of detection (LOD) at a signal-to-noise (S/N) ratio of 3 were 0.25-6.0 ng/g. The alteration of estrogens levels induced by BPA may play important role to understanding probable endocrine disruptive exposure, and the described methods could be used to evaluate and monitor exposure of endocrine disruptor.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 50 条
  • [31] Determination of neutral pharmaceuticals in wastewater and rivers by liquid chromatography-electrospray tandem mass spectrometry
    Ternes, T
    Bonerz, M
    Schmidt, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 938 (1-2) : 175 - 185
  • [32] Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Salem, II
    Idrees, J
    Al Tamimi, JI
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (01): : 103 - 109
  • [33] Determination of clarithromycin in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Jiang, Yao
    Wang, Jiang
    Li, Hao
    Wang, Yingwu
    Gu, Jingkai
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) : 1460 - 1464
  • [34] Determination of Botanical Insecticides Residues in Fish by Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    Yang, Fang
    Liu, Zhencai
    Zhen, Danping
    Lin, Yonghui
    Chen, Jian
    Ruan, Jun
    Chen, Guonan
    [J]. FOOD ANALYTICAL METHODS, 2011, 4 (04) : 601 - 607
  • [35] Determination of bile acids in biological fluids by liquid chromatography-electrospray tandem mass spectrometry
    Perwaiz, S
    Tuchweber, B
    Mignault, D
    Gilat, T
    Yousef, IM
    [J]. JOURNAL OF LIPID RESEARCH, 2001, 42 (01) : 114 - 119
  • [36] Determination of Fatty Acids in Beef by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Laiel C. Soliman
    Elizabeth M. Andrucson
    Kingsley K. Donkor
    John S. Church
    Bruno Cinel
    [J]. Food Analytical Methods, 2016, 9 : 630 - 637
  • [37] Determination of flumazenil in human plasma by liquid chromatography-electrospray ionisation tandem mass spectrometry
    Lavén, M
    Appel, L
    Moulder, R
    Tyrefors, N
    Markides, K
    Långström, B
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (02): : 221 - 227
  • [38] Determination of bulleyaconitine A in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Weng, WY
    Xu, HN
    Huang, JM
    Wang, GQ
    Shen, T
    Zhang, JF
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 315 - 320
  • [39] Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Kim, HY
    Chang, KY
    Lee, HJ
    Han, SB
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (01) : 109 - 114
  • [40] Rapid determination of orotic acid in urine by liquid chromatography-electrospray tandem mass spectrometry
    Rashed, MS
    Jacob, M
    Al-Amoudi, M
    Rahbeeni, Z
    Al-Sayed, MAD
    Al-Ahaidib, L
    Saadallah, AAA
    Legaspi, S
    [J]. CLINICAL CHEMISTRY, 2003, 49 (03) : 499 - 501