Simultaneous determination of bisphenol A and estrogens in hair samples by liquid chromatography-electrospray tandem mass spectrometry

被引:33
|
作者
Lee, Chaelin [1 ,2 ]
Kim, Chong Hyeak [1 ]
Kim, Sunghwan [2 ]
Cho, Sung-Hee [1 ]
机构
[1] KRICT, Ctr Chem Anal, Daejeon 305600, South Korea
[2] Kyungpook Natl Univ, Dept Chem, Daegu 41566, South Korea
关键词
Bisphenol A; Estrogens; Hair; Liquid chromatography; Mass spectrometry; HUMAN URINE; ENVIRONMENTAL ESTROGENS; ENDOCRINE; QUANTIFICATION; VALIDATION; EXPOSURE; DERIVATIZATION; ASSOCIATION; DANSYLATION; IONIZATION;
D O I
10.1016/j.jchromb.2017.05.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bisphenol A (BPA), an endocrine disrupter, is widely used to make chemicals for polycarbonate, plastics, beverage containers, epoxy resins, and cash register receipts. BPA is one of the known xenoestrogens, which have weak estrogenic activity and cause obesity, diabetes, breast cancer, and reproductive disorders. Even though the concentration level of metabolomes in hair is usually lower than that in urine and blood, there are several reasons why we chose to use hair samples. First, the sampling procedure of hairs is simple. Second, it is also easy to preserve the sample for long term and track the drug-exposure record of a given sample. Third, deformation and contamination of samples rarely occur. In this study, an improved analytical method to determine the levels of BPA and estrogens in hair samples was developed by liquid chromatography-electrospray tandem mass spectrometry (LC-ESI/MS/MS). Hair samples were extracted by an Oasis HLB extraction cartridge after incubation with 1 N HCl and derivatized with dansyl chloride to increase sensitivity. BPA and estrogens (estrone, 17 beta-estradiol, and estriol) were separated using Shiseido CAPCELL PAK C-18 column (2.0 x 100 mm, 3 mu m) and a mobile phase consisting of 10 mM ammonium acetate in water and acetonitrile with a gradient program at a flow rate of 0.3 mL/min and were monitored with electrospray tandem mass spectrometry (ESI MS/MS). The linearity of this method was over 0.995. The limits of detection (LOD) at a signal-to-noise (S/N) ratio of 3 were 0.25-6.0 ng/g. The alteration of estrogens levels induced by BPA may play important role to understanding probable endocrine disruptive exposure, and the described methods could be used to evaluate and monitor exposure of endocrine disruptor.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 50 条
  • [21] Determination of gestrinone in human serum by liquid chromatography-electrospray tandem mass spectrometry
    Wang, QG
    Wu, ZP
    Wang, YM
    Luo, GA
    Wu, E
    Gao, XF
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 746 (02): : 151 - 159
  • [22] Determination of Glucocorticoids in Muscle Tissues by Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    Gong Lan
    Chen Ming
    Wei Xian
    Zou Chun
    Wang Ran
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (01) : 74 - 80
  • [23] Simultaneous determination of tetrabromobisphenol A, tetrachlorobisphenol A, bisphenol A and other halogenated analogues in sediment and sludge by high performance liquid chromatography-electrospray tandem mass spectrometry
    Chu, SG
    Haffner, GD
    Letcher, RJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1097 (1-2) : 25 - 32
  • [24] Simultaneous determination of sulfonamides and fluoroquinolones residues in chicken by high performance liquid chromatography-electrospray tandem mass spectrometry
    Liu Pengyan
    Jiang Ning
    Wang Yingfeng
    Yan Lizhi
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (03) : 348 - 352
  • [25] Simultaneous determination of tetrahydrocortisol, allotetrahydrocortisol and tetrahydrocortisone in human urine by liquid chromatography-electrospray ionization tandem mass spectrometry
    Yamashita, Kouwa
    Nakagawa, Risa
    Okuyama, Mitsunobu
    Honma, Seijim
    Takahashi, Madoka
    Numazawa, MitsuteTu
    [J]. STEROIDS, 2008, 73 (07) : 727 - 737
  • [26] Determination of hexaconazole in surface water samples from river and the sea by liquid chromatography-electrospray tandem mass spectrometry
    Tsukatani, Hiroko
    Tobiishi, Kazuhiro
    Tanaka, Yoshito
    Sakuragi, Kenji
    Ikeura, Tasoh
    Nakamura, Matayoshi
    [J]. BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2008, 72 (01) : 149 - 154
  • [27] Determination of Perfluorinated Compounds in Human Blood Samples by High Performance Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    Pan Yuan-Yuan
    Shi Ya-Li
    Cai Ya-Qi
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (10) : 1321 - 1326
  • [28] Simultaneous Determination of Twelve Glucocorticoids Residues in Milk by Ultra Performance Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    Cui Xiaoliang
    Shao Bing
    Zhao Rong
    Meng Juan
    Tu Xiaoming
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2006, 24 (03) : 213 - 217
  • [29] Simultaneous Determination of 8 Poisonous Alkaloids in Human Blood by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Xiong Xiao-Ting
    Wu Hui-Qin
    Huang Xiao-Lan
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (10) : 1433 - 1438
  • [30] Determination of tetrabromobisphenol A in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry
    Hayama, T
    Yoshida, H
    Onimaru, S
    Yonekura, S
    Kuroki, H
    Todoroki, K
    Nohta, H
    Yamaguchi, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01): : 131 - 136