Evaluation of body fluid status after cardiac surgery using bioelectrical impedance analysis

被引:0
|
作者
Yamaguchi, H [1 ]
Yamauchi, H [1 ]
Hazama, S [1 ]
Hamamoto, H [1 ]
机构
[1] Nagasaki Univ, Sch Med, Dept Cardiovasc Surg, Nagasaki 852, Japan
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2000年 / 41卷 / 04期
关键词
electric impedance; cardiopulmonary bypass cardiac; surgical procedures; body water; body composition;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In. the assessment of fluid status after cardiac surgery, we applied bioelectrical impedance analysis (BIA) to measure the total body water (TBW), extracellular fluid (ECF), and intracellular fluid (ICF), and evaluated its validity. Methods. Thirty patients who underwent cardiopulmonary bypass (CPB group) and 19 surgical patients not receiving CPB (non-CPB group). Results. The change of BIA values (Delta TBW, Delta ECF, Delta ICF), body weight and cumulative fluid balance were determined for 120 postoperative hours, and the relationship between BIA values and body weight and fluid balance were evaluated. Postoperative changes in BIA values in the CPB group were compared with those in the non-CPB group. Finally the ECF/ICF ratio and hemodynamic parameters were compared. Delta TBW and Delta ECF correlated with changes in body weight and fluid balance, respectively. Especially there was a high correlation in each case although large deviations in the slope of the regression lines were observed TBW and ECF increased from immediately after operation up to 96 hours (the maximum value was at day 2). On the other hand, ICF decreased from 48 to 72 hours after operation. There were significant high ECF/ICF in the CPB group compared with the non-CPB group from 12 to 72 postoperative hours. We found that ECF/ICF correlated inversely with mean blood pressure, mixed venous oxygen saturation and colloid osmotic pressure, acid positively with central venous pressure and pulmonary artery wedge pressure. Conclusions. It was considered that BIA was useful for evaluating the relative changes in TBW and fluid distribution, and ECF/ICF might be a new parameter for abnormal water metabolism after cardiac surgery.
引用
收藏
页码:559 / 566
页数:8
相关论文
共 50 条
  • [41] Evaluation Of Muscle Swelling After Concentric Muscle Contraction Using Bioelectrical Impedance Analysis
    Imai, Ayano
    Iwata, Ayame
    Inaka, Chisa
    Sakaue, Yusuke
    Goto, Kazushige
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 83 - 84
  • [42] Body Composition Evaluation of Elementary School Students Using Bioelectrical Impedance Analysis in South Korea
    Cho, Chaeeun
    Jeon, Kyoungkyu
    Lee, Sewon
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2023, 52 (02) : 449 - 450
  • [43] Evaluation of fluid status in patients with acromegaly through bioelectrical impedance vector analysis: a cross-sectional study
    Varaldo, Emanuele
    Prencipe, Nunzia
    Berton, Alessandro Maria
    Cuboni, Daniela
    Aversa, Luigi Simone
    Sibilla, Michela
    Mocellini, Francesca
    Bioletto, Fabio
    Ghigo, Ezio
    Gasco, Valentina
    Grottoli, Silvia
    JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2025, : 1185 - 1195
  • [44] USE OF BIOELECTRICAL-IMPEDANCE ANALYSIS (BIA) FOR THE EVALUATION OF BODY-FLUID COMPOSITION IN HEMODIALYSIS AND CAPD PATIENTS
    PLUM, J
    LUBBE, M
    GRABENSEE, B
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 525 - 525
  • [45] USE OF BIOELECTRICAL-IMPEDANCE ANALYSIS (BIA) FOR THE EVALUATION OF BODY-FLUID COMPOSITION IN HEMODIALYSIS AND CAPD PATIENTS
    PLUM, J
    LUBBE, M
    GRABENSEE, B
    KIDNEY INTERNATIONAL, 1995, 47 (03) : 993 - 993
  • [46] The effect of acute fluid consumption on measures of impedance and percent body fat using leg-to-leg bioelectrical impedance analysis
    C B Dixon
    S J LoVallo
    J L Andreacci
    F L Goss
    European Journal of Clinical Nutrition, 2006, 60 : 142 - 146
  • [47] The effect of acute fluid consumption on measures of impedance and percent body fat using leg-to-leg bioelectrical impedance analysis
    Dixon, CB
    LoVallo, SJ
    Andreacci, JL
    Goss, FL
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2006, 60 (01) : 142 - 146
  • [48] Estimation of acute fluid shifts using bioelectrical impedance analysis in horses
    Fielding, C. Langdon
    Magdesian, K. Gary
    Carlson, Gary P.
    Ruby, Rebecca E.
    Rhodes, Diane M.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2007, 21 (01) : 176 - 183
  • [49] Preoperative body composition measured by bioelectrical impedance analysis can predict pancreatic fistula after pancreatic surgery
    Jin, Qianwen
    Zhang, Jun
    Jin, Jiabin
    Zhang, Jiaqiang
    Fei, Si
    Liu, Yang
    Xu, Zhiwei
    Shi, Yongmei
    NUTRITION IN CLINICAL PRACTICE, 2025, 40 (01) : 156 - 166
  • [50] Validity of Bioelectrical Impedance Analysis to Estimate Body Composition Changes After Bariatric Surgery in Premenopausal Morbidly Women
    Silvia Savastano
    Annamaria Belfiore
    Carolina Di Somma
    Concetta Mauriello
    Annalisa Rossi
    Genoveffa Pizza
    Annalba De Rosa
    Giovanni Prestieri
    Luigi Angrisani
    Annamaria Colao
    Obesity Surgery, 2010, 20 : 332 - 339