Evaluation of body fluid status after cardiac surgery using bioelectrical impedance analysis

被引:0
|
作者
Yamaguchi, H [1 ]
Yamauchi, H [1 ]
Hazama, S [1 ]
Hamamoto, H [1 ]
机构
[1] Nagasaki Univ, Sch Med, Dept Cardiovasc Surg, Nagasaki 852, Japan
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2000年 / 41卷 / 04期
关键词
electric impedance; cardiopulmonary bypass cardiac; surgical procedures; body water; body composition;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In. the assessment of fluid status after cardiac surgery, we applied bioelectrical impedance analysis (BIA) to measure the total body water (TBW), extracellular fluid (ECF), and intracellular fluid (ICF), and evaluated its validity. Methods. Thirty patients who underwent cardiopulmonary bypass (CPB group) and 19 surgical patients not receiving CPB (non-CPB group). Results. The change of BIA values (Delta TBW, Delta ECF, Delta ICF), body weight and cumulative fluid balance were determined for 120 postoperative hours, and the relationship between BIA values and body weight and fluid balance were evaluated. Postoperative changes in BIA values in the CPB group were compared with those in the non-CPB group. Finally the ECF/ICF ratio and hemodynamic parameters were compared. Delta TBW and Delta ECF correlated with changes in body weight and fluid balance, respectively. Especially there was a high correlation in each case although large deviations in the slope of the regression lines were observed TBW and ECF increased from immediately after operation up to 96 hours (the maximum value was at day 2). On the other hand, ICF decreased from 48 to 72 hours after operation. There were significant high ECF/ICF in the CPB group compared with the non-CPB group from 12 to 72 postoperative hours. We found that ECF/ICF correlated inversely with mean blood pressure, mixed venous oxygen saturation and colloid osmotic pressure, acid positively with central venous pressure and pulmonary artery wedge pressure. Conclusions. It was considered that BIA was useful for evaluating the relative changes in TBW and fluid distribution, and ECF/ICF might be a new parameter for abnormal water metabolism after cardiac surgery.
引用
收藏
页码:559 / 566
页数:8
相关论文
共 50 条
  • [21] Evaluation of nutritional status using bioelectrical impedance analysis in patients with inflammatory bowel disease
    Kim, Seung Hyuk
    Kim, You Sun
    Lee, Si Hyeong
    Lee, Hyun Mi
    Yoon, Won Eui
    Kim, Seo Hyun
    Myung, Hee Jun
    Moon, Jeong Seop
    INTESTINAL RESEARCH, 2022, 20 (03) : 321 - 328
  • [22] Postoperative Changes in Body Composition After Pancreaticoduodenectomy Using Multifrequency Bioelectrical Impedance Analysis
    Mikamori, Manabu
    Miyamoto, Atsushi
    Asaoka, Tadafumi
    Maeda, Sakae
    Hama, Naoki
    Yamamoto, Kazuyoshi
    Hirao, Motohiro
    Ikeda, Masataka
    Sekimoto, Mitsugu
    Doki, Yuichiro
    Mori, Masaki
    Nakamori, Shoji
    JOURNAL OF GASTROINTESTINAL SURGERY, 2016, 20 (03) : 611 - 618
  • [23] Postoperative Changes in Body Composition After Pancreaticoduodenectomy Using Multifrequency Bioelectrical Impedance Analysis
    Manabu Mikamori
    Atsushi Miyamoto
    Tadafumi Asaoka
    Sakae Maeda
    Naoki Hama
    Kazuyoshi Yamamoto
    Motohiro Hirao
    Masataka Ikeda
    Mitsugu Sekimoto
    Yuichiro Doki
    Masaki Mori
    Shoji Nakamori
    Journal of Gastrointestinal Surgery, 2016, 20 : 611 - 618
  • [24] Use of bioelectrical impedance analysis to estimate body fluid compartments after acute hypohydration in male rowers
    Jürimäe, J
    Jürimäe, T
    Sööt, T
    XXVII FIMS: WORLD CONGRESS OF SPORTS MEDICINE, 2002, : 9 - 12
  • [25] Feasibility study using longitudinal bioelectrical impedance analysis to evaluate body water status during fluid resuscitation in a swine sepsis model
    Jeong, Hwain
    Park, Inwon
    Lee, Jae Hyuk
    Kim, Dongsung
    Baek, Sumin
    Kim, Seonghye
    Jo, You Hwan
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2022, 10 (01)
  • [26] Feasibility study using longitudinal bioelectrical impedance analysis to evaluate body water status during fluid resuscitation in a swine sepsis model
    Hwain Jeong
    Inwon Park
    Jae Hyuk Lee
    Dongsung Kim
    Sumin Baek
    Seonghye Kim
    You Hwan Jo
    Intensive Care Medicine Experimental, 10
  • [27] The effect of acute fluid consumption on measures of impedance and percent body fat estimated using segmental bioelectrical impedance analysis
    C B Dixon
    L Ramos
    E Fitzgerald
    D Reppert
    J L Andreacci
    European Journal of Clinical Nutrition, 2009, 63 : 1115 - 1122
  • [28] The effect of acute fluid consumption on measures of impedance and percent body fat estimated using segmental bioelectrical impedance analysis
    Dixon, C. B.
    Ramos, L.
    Fitzgerald, E.
    Reppert, D.
    Andreacci, J. L.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2009, 63 (09) : 1115 - 1122
  • [29] MEASUREMENT OF BODY-COMPOSITION USING BIOELECTRICAL IMPEDANCE ANALYSIS
    LUBANSKI, RE
    KURZER, M
    MEGUID, MM
    CLINICAL RESEARCH, 1987, 35 (03): : A775 - A775
  • [30] Validity of Bioelectrical Impedance Analysis for Measuring Changes in Body Water and Percent Fat After Bariatric Surgery
    Elizabeth M. Widen
    Gladys Strain
    Wendy C. King
    Wenwen Yu
    Susan Lin
    Bret Goodpaster
    John Thornton
    Anita Courcoulas
    Alfons Pomp
    Dympna Gallagher
    Obesity Surgery, 2014, 24 : 847 - 854