Evaluation of body fluid status after cardiac surgery using bioelectrical impedance analysis

被引:0
|
作者
Yamaguchi, H [1 ]
Yamauchi, H [1 ]
Hazama, S [1 ]
Hamamoto, H [1 ]
机构
[1] Nagasaki Univ, Sch Med, Dept Cardiovasc Surg, Nagasaki 852, Japan
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2000年 / 41卷 / 04期
关键词
electric impedance; cardiopulmonary bypass cardiac; surgical procedures; body water; body composition;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In. the assessment of fluid status after cardiac surgery, we applied bioelectrical impedance analysis (BIA) to measure the total body water (TBW), extracellular fluid (ECF), and intracellular fluid (ICF), and evaluated its validity. Methods. Thirty patients who underwent cardiopulmonary bypass (CPB group) and 19 surgical patients not receiving CPB (non-CPB group). Results. The change of BIA values (Delta TBW, Delta ECF, Delta ICF), body weight and cumulative fluid balance were determined for 120 postoperative hours, and the relationship between BIA values and body weight and fluid balance were evaluated. Postoperative changes in BIA values in the CPB group were compared with those in the non-CPB group. Finally the ECF/ICF ratio and hemodynamic parameters were compared. Delta TBW and Delta ECF correlated with changes in body weight and fluid balance, respectively. Especially there was a high correlation in each case although large deviations in the slope of the regression lines were observed TBW and ECF increased from immediately after operation up to 96 hours (the maximum value was at day 2). On the other hand, ICF decreased from 48 to 72 hours after operation. There were significant high ECF/ICF in the CPB group compared with the non-CPB group from 12 to 72 postoperative hours. We found that ECF/ICF correlated inversely with mean blood pressure, mixed venous oxygen saturation and colloid osmotic pressure, acid positively with central venous pressure and pulmonary artery wedge pressure. Conclusions. It was considered that BIA was useful for evaluating the relative changes in TBW and fluid distribution, and ECF/ICF might be a new parameter for abnormal water metabolism after cardiac surgery.
引用
收藏
页码:559 / 566
页数:8
相关论文
共 50 条
  • [1] Fluid Status After Cardiac Surgery Assessed by Bioelectrical Impedance Vector Analysis and the Effects of Extracorporeal Circulation
    Costa, Diego
    Muzzio, Maximiliano
    Saglietti, Luciano
    Budelli, Silvina
    Gonzalez, Carlos L.
    Catena, Enzo
    Corsico, Luciana
    Garcia Iturralde, Leonardo
    Esperon, Guillermina
    Gregorietti, Vanesa
    Coronel, Roberto
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (08) : 2385 - 2391
  • [2] Bedside determination of fluid accumulation after cardiac surgery using segmental bioelectrical impedance
    Bracco, D
    Revelly, JP
    Berger, MM
    Chioléro, RL
    CRITICAL CARE MEDICINE, 1998, 26 (06) : 1065 - 1070
  • [3] FLUID STATUS ASSESSMENT USING BIOELECTRICAL IMPEDANCE ANALYSIS IN ELDERLY HEMODIALYSIS PATIENTS
    Gincaite, Alvita
    Vicka, Vaidas
    Sukackiene, Diana
    Gudynaite, Migle
    Laucyte-Cibulskiene, Agne
    Rimsevicius, Laurynas
    Miglinas, Marius
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2017, 32
  • [4] Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
    Castillo-Martinez, Lilia
    Bernal-Ceballos, Fernanda
    Reyes-Paz, Yunuen
    Hernandez-Gilsoul, Thierry
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (186):
  • [5] Bioelectrical impedance analysis for assessment of fluid status and body composition in neonates—the good, the bad and the unknown
    B E Lingwood
    European Journal of Clinical Nutrition, 2013, 67 : S28 - S33
  • [6] Evaluation of lymph drainage using bioelectrical impedance of the body
    de Godoy, J. M. P.
    Valente, F. M.
    Azoubel, L. M.
    Godoy, M. F. G.
    PHLEBOLOGY, 2011, 26 (07) : 298 - 300
  • [7] Evaluation Of A Bioelectrical Impedance Device In The Analysis Of Body Composition
    Gogain, Melissa
    Schoffstall, James
    McLaughlin, James
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 317 - 317
  • [8] Evaluation Of A Bioelectrical Impedance Device In The Analysis Of Body Composition
    Gogain, Melissa
    Schoffstall, James
    McLaughlin, James
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 317 - 317
  • [9] Body fluid overload and bioelectrical impedance analysis in renal patients
    Piccoli, A
    Rossi, B
    Pillon, L
    Bucciante, G
    MINERAL AND ELECTROLYTE METABOLISM, 1996, 22 (1-3) : 76 - 78
  • [10] Bioelectrical impedance analysis to assess changes in body water compartments after digestive surgery
    Hanaki, Norikazu
    Ishikawa, Masashi
    Nishioka, Masanori
    Kashiwagi, Yutaka
    Miki, Hisashi
    Miyake, Hidenori
    Tashiro, Seiki
    HEPATO-GASTROENTEROLOGY, 2006, 53 (71) : 723 - 729