In connection with the reconstruction and capacity extension of the Frederikshavn Central Wastewater Treatment Plant in the period between 1989 and 1995 the existing activated sludge plant (AS) was supplemented with a biological aerated filter (BAF). The parallel operation with two wastewater flows has made a comparison of the two plants possible in relation to operating data, operating costs and experience. For the purpose of optimizing the operation, tests were conducted to increase the hydraulic capacity of the plant during rain and control strategies for the plants were considered for dry weather as well as wet weather situations. This paper discusses the experience gained from the plant operation as well as the considerations made in relation to future control strategies and possibilities of increasing the total hydraulic capacity during rain.
引用
收藏
页码:159 / 168
页数:10
相关论文
共 50 条
  • [21] Average modeling of an alternating aerated activated sludge process for nitrogen removal
    Belandria, Maria
    Gomez, Claudia
    Maquez, Richard
    Rios, Miguel
    [J]. CIENCIA E INGENIERIA, 2012, 33 (02): : 105 - 112
  • [22] The experimental study of contaminant removal in water quenched slag biological aerated filter (BAF)
    Gao, Longlong
    Yu, Yanzhen
    Li, Miaowan
    Zhou, Yuxing
    Zhang, Huadong
    [J]. PROGRESS IN MATERIALS AND PROCESSES, PTS 1-3, 2013, 602-604 : 1171 - 1174
  • [23] The characteristic research of ammonium removal in grain-slag biological aerated filter (BAF)
    Feng, Yan
    Yu, Yanzhen
    Duan, Qinan
    Tan, Juan
    Zhao, Chunhui
    [J]. DESALINATION, 2010, 263 (1-3) : 146 - 150
  • [24] Performance of nitrogen removal in an alternating activated sludge reactor for full-scale applications
    Li, Jun
    Li, Kunquan
    Berns, Erin
    Wang, Hanting
    Sadik, Nora
    Shen, Yun
    Li, Xuebin
    Tao, Tao
    [J]. ENVIRONMENTAL TECHNOLOGY, 2020, 41 (05) : 627 - 637
  • [25] Comparison of 4-Stage Biological Aerated Filter (BAF) with MLE Process in Nitrogen Removal from Low Carbon-to-Nitrogen Wastewater
    Ryu, Hong-Duck
    Lee, Sang-Ill
    [J]. ENVIRONMENTAL ENGINEERING SCIENCE, 2009, 26 (01) : 163 - 170
  • [26] Experience with an up-flow biological aerated filter (BAF) for tertiary treatment: from pilot trials to full scale implementation
    Payraudeau, M
    Pearce, AR
    Goldsmith, R
    Bigot, B
    Wicquart, F
    [J]. WATER SCIENCE AND TECHNOLOGY, 2001, 44 (2-3) : 63 - 68
  • [27] Impact of Partial Backwashing to Ammonia Nitrogen Removal in Biological Aerated Filter
    Li, Ping
    Yan, Lilong
    Ma, Fang
    [J]. ENVIRONMENTAL BIOTECHNOLOGY AND MATERIALS ENGINEERING, PTS 1-3, 2011, 183-185 : 720 - +
  • [28] Total nitrogen removal in a hybrid, membrane-aerated activated sludge process
    Downing, Leon S.
    Nerenberg, Robert
    [J]. WATER RESEARCH, 2008, 42 (14) : 3697 - 3708
  • [29] Chemical control of filamentous sludge bulking in a full-scale biological nutrient removal activated sludge plant
    Saayman, GB
    Schutte, CF
    van Leeuwen, J
    [J]. OZONE-SCIENCE & ENGINEERING, 1998, 20 (01) : 1 - 15
  • [30] BIOLOGICAL PHOSPHORUS REMOVAL IN CONNECTION WITH OXYGEN AERATED ACTIVATED-SLUDGE PLANTS
    SCHONBERGER, R
    HEGEMANN, W
    [J]. WATER SCIENCE AND TECHNOLOGY, 1985, 17 (11-1) : 321 - 323