A portal image based quality assurance program using a commercial portal dosimetry software

被引:0
|
作者
Guerrero, M. [1 ]
Patel, I. [1 ]
机构
[1] Dept Vet Affairs Med Ctr, Washington, DC USA
关键词
D O I
10.1118/1.2760375
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: There is an increasing trend in Radiation Oncology Departments to replace film as a tool for localization hence Medical Physicists increasingly find themselves without access to a film processor. Films are typically used for standard routine quality assurance (QA) of linear accelerators and IMRT commissioning and verifications. The purpose of this work is to develop a QA program using a commercial electronic portal imager (EPID) and commercial portal dosimetry software available on Varian Linear Accelerators. Method and Materials: Using Varian aS500 Portal Imager with the Portal Dosimetry Calculation (PDC) from Eclipse (commissioned according to manufacturer's recommendations), we perform a series of measurements associated with Linac QA (light‐field coincidence, flatness and symmetry, off‐axis ratios, etc), IMRT verifications and static and dynamic MLC QA. For light‐filed coincidence we use the gradicule to “mark” the edges of the light field. For flatness and symmetry we determine a “baseline” using a phantom measurement at 10cm depth and establishing a correspondence with the Portal Imager measurement. Similar baselines are established for off‐axis ratios and other measurements. Results: We present the results of our QA measurements; analyze their level of difficulty and convenience as compared with the use of film. The QA measurements performed with the portal imager are consistent with the results from our film measurements. The IMRT verifications performed with the EPID are also consistent with the ones performed with our commercial two‐dimensional diode array. We find that after we became familiar with the use of the Portal Imager and the software, the QA measurements with the portal imager are adequate and in many cases more convenient than the use of film. Conclusion: An appropriate Linac and IMRT QA program can be developed using the Varian aS500 EPID in combination with the Eclipse Portal Dosimetry Calculation. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2337 / 2337
页数:1
相关论文
共 50 条
  • [21] Detector aging and quality assurance of iViewGT a-Si EPIDS with regard to portal dosimetry
    Winkler, P.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S157 - S157
  • [22] The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy
    Nicolini, Giorgia
    Vanetti, Eugenio
    Clivio, Alessandro
    Fogliata, Antonella
    Korreman, Stine
    Bocanek, Jiri
    Cozzi, Luca
    RADIATION ONCOLOGY, 2008, 3 (1)
  • [23] Use of portal dosimetry in IMRT verification and quality assurance of multi-leaf-collimator
    Hierholz, K.
    Kober, B.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 51 - 51
  • [24] A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
    Jomehzadeh, A.
    Shokrani, P.
    Mohammadi, M.
    Amouheidari, A.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2014, 12 (03): : 257 - 264
  • [25] Simple Proposal for Dosimetry with an Elekta iViewGT™ Electronic Portal Imaging Device (EPID) Using Commercial Software Modules
    Liebich, Janett
    Licher, Joerg
    Scherf, Christian
    Kara, Eugen
    Koch, Nadine
    Roedel, Claus
    Ramm, Ulla
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (05) : 316 - 321
  • [26] Quality assurance of linacs using the electronic portal imager.
    Woo, M
    Li, Y
    Pang, G
    RADIOTHERAPY AND ONCOLOGY, 2004, 72 : S60 - S60
  • [27] Quality assurance of Linac-based stereotactic radiotherapy with electronic portal image device (WIP)
    Hsu, CW
    Liu, WS
    Chang, HC
    Chuang, KS
    Chen, TJ
    Tsai, CT
    MEDICAL PHYSICS, 2003, 30 (06) : 1520 - 1520
  • [28] Automated stereotactic radiosurgery quality assurance using a portal imager
    Mamalui-Hunter, M.
    Drzymala, R.
    Willcut, V.
    Santanam, L.
    Low, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2642 - 2642
  • [29] Varian and Elekta quality assurance using artificial neural network based on portal imaging
    Chatrie, F.
    Vasseur, A.
    Barbeiro, A. R.
    Younan, F.
    Mazurier, J.
    Le Lann, M. V.
    Franceries, X.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1166 - S1166
  • [30] On the Feasibility of Angle-Resolved Portal Dosimetry for Patient Specific Quality Assurance of VMAT Plans
    Draeger, E.
    Donahue, W.
    Chen, Z.
    MEDICAL PHYSICS, 2020, 47 (06) : E820 - E820