Evaluation of a miniaturized thermal biosensor for the determination of glucose in whole blood

被引:31
|
作者
Harborn, U
Xie, B
Venkatesh, R
Danielsson, B
机构
[1] Univ Lund, Ctr Chem, Dept Pure & Appl Biochem, S-22100 Lund, Sweden
[2] Voluntary Hlth Serv, PROMED, Madras 600113, Tamil Nadu, India
关键词
flow injection analysis; thermal; calorimetric; biosensor; glucose oxidase; calibration aspects; diabetes; enzyme thermistor;
D O I
10.1016/S0009-8981(97)00151-4
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A miniaturized thermal biosensor has been evaluated as part of a flow-injection analysis system for the determination of glucose in whole blood. Glucose was determined by measuring the heat evolved when samples containing glucose passed through a small column with immobilized glucose oxidase and catalase. Samples of whole blood (1 mu l) can be measured directly, without any pretreatment. The correlation in the response between the thermal biosensor, the Reflolux S meter (Boehringer Mannheim), the Granutest 100 glucose test kit (Merck Diagnostica) and the Ektachem (Kodak) instrument was evaluated. The influence of the hematocrit value and of possible interferences is reported. The correlation measurements show that the thermal biosensor calibrated with aqueous glucose standards generally gives lower values on blood glucose than the reference methods calibrated for serum or blood measurements. Mean negative biases range from 0.53 to 1.16 mmol/l. Differences in sample treatment clearly complicate comparisons and the proper choice of reference method. There was no influence from substances such as ascorbic acid (0.11 mmol/l), uric acid (0.48 mmol/l), urea (4.3 mmol/l) and acetaminophen (0.17 mmol/l) on the response to 5 mmol/l glucose. The hematocrit value does not influence the glucose determination, for hematocrit values of between 13 and 53%. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:225 / 237
页数:13
相关论文
共 50 条
  • [1] Clinical evaluation of a new, miniaturized biosensor for self-monitoring of blood glucose
    Albertson, C
    Davis, C
    Ellison, J
    Chu, C
    [J]. CLINICAL CHEMISTRY, 1998, 44 (09) : 2056 - 2057
  • [2] Highly miniaturized and integrated biosensor for analysis of whole blood samples
    Schaffar, BPH
    Kontschieder, H
    Ritter, C
    Berger, H
    [J]. CLINICAL CHEMISTRY, 1999, 45 (09) : 1678 - 1679
  • [3] FAST DETERMINATION OF WHOLE-BLOOD GLUCOSE WITH A CALORIMETRIC MICRO-BIOSENSOR
    XIE, B
    HEDBERG, U
    MECKLENBURG, M
    DANIELSSON, B
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1993, 15 (1-3) : 141 - 144
  • [4] DETERMINATION OF GLUCOSE IN DILUTED BLOOD WITH A THERMAL FLOW-INJECTION ANALYSIS BIOSENSOR
    HARBORN, U
    XIE, B
    DANIELSSON, B
    [J]. ANALYTICAL LETTERS, 1994, 27 (14) : 2639 - 2645
  • [5] Disposable biosensor for hemoglobin determination in whole blood
    Jiang, Liying
    Luo, Xianbo
    Tian, Qing
    Wang, Hui
    Cai, XinXia
    [J]. 2006 1ST IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2006, : 204 - 208
  • [6] UREA AND LACTATE DETERMINED IN 1-MU-L WHOLE-BLOOD SAMPLES WITH A MINIATURIZED THERMAL BIOSENSOR
    XIE, B
    HARBORN, U
    MECKLENBURG, M
    DANIELSSON, B
    [J]. CLINICAL CHEMISTRY, 1994, 40 (12) : 2282 - 2287
  • [7] Evaluation of a biosensor for the measurement of lactate in whole blood
    de Keijzer, MH
    Brandts, RW
    Brans, PGW
    [J]. CLINICAL BIOCHEMISTRY, 1999, 32 (02) : 109 - 112
  • [8] AMPEROMETRIC GLUCOSE BIOSENSOR FOR AN UNDILUTED WHOLE-BLOOD ANALYSIS
    MATUSZEWSKI, W
    TROJANOWICZ, M
    LEWENSTAM, A
    MOSZCZYNSKA, A
    LANGEMOROZ, E
    [J]. ANALYTICAL SCIENCES, 1994, 10 (03) : 423 - 428
  • [9] Evaluation of SH-SAW Biosensor in Whole Blood
    Kano, Koji
    Kogai, Takashi
    Yatsuda, Hiromi
    Liu, Szu-Heng
    Huang, Yi-Qi
    Huang, Yu-Tung
    Chen, Pei-Jer
    [J]. 2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [10] Enzyme electrode for glucose determination in whole blood
    Santoni, T
    Santianni, D
    Manzoni, A
    Zanardi, S
    Mascini, M
    [J]. TALANTA, 1997, 44 (09) : 1573 - 1580