DETERMINATION OF GLUCOSE IN DILUTED BLOOD WITH A THERMAL FLOW-INJECTION ANALYSIS BIOSENSOR

被引:6
|
作者
HARBORN, U
XIE, B
DANIELSSON, B
机构
[1] Department of Pure and Applied Biochemistry, Chemical Center, University of Lund, S-221 00
关键词
THERMAL BIOSENSOR; GLUCOSE OXIDASE; GLUCOSE; WHOLE BLOOD;
D O I
10.1080/00032719408005996
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The glucose concentration in diluted whole blood has been measured, using a miniaturized thermal biosensor based on the enzyme thermistor principle. The biosensor is a small flow injection system. A sample volume of 20 mu l is injected into a flow of 50 mu l/min. The heat produced when the sample passes the enzyme column is measured with a thermistor connected to a Wheatstone bridge. The enzyme column contains glucose oxidase and catalase co-immobilized on a solid support material. Samples of whole blood usually cause problems in flow-systems. The blood cells tend to block the enzyme column and the back pressure increases. We have tested a superporous agarose material as enzyme support material using tenfold diluted samples of whole human blood. The blood was collected from the finger-tip and diluted with buffer containing an anticoagulant and sodium fluoride. The number of samples possible to inject and the accuracy compared to the Boehringer Mannheim Reflolux have been determined. At least 100 ten-fold diluted blood samples could be injected on a micro-column of superporous agarose. The obtained glucose concentration correlated well with the one obtained with the reference instrument.
引用
收藏
页码:2639 / 2645
页数:7
相关论文
共 50 条
  • [1] Voltammetric flow-injection determination of glucose in blood serum
    Fitsev, IM
    Bakanina, YN
    Abdullin, IF
    Budnikov, GK
    [J]. INDUSTRIAL LABORATORY, 1998, 64 (07): : 426 - 427
  • [2] DETERMINATION OF GLUCOSE IN BLOOD BY FLOW-INJECTION ANALYSIS AND AN IMMOBILIZED GLUCOSE-OXIDASE COLUMN
    MASOOM, M
    TOWNSHEND, A
    [J]. ANALYTICA CHIMICA ACTA, 1984, 166 (DEC) : 111 - 118
  • [3] DETERMINATION OF URINARY GLUCOSE BY A FLOW-INJECTION ANALYSIS AMPEROMETRIC BIOSENSOR AND ION-EXCHANGE CHROMATOGRAPHY
    MALE, KB
    LUONG, JHT
    [J]. APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1992, 37 (03) : 243 - 254
  • [4] CHEMILUMINESCENT FLOW-INJECTION ANALYSIS OF GLUCOSE IN DRINKS WITH A BIENZYME FIBEROPTIC BIOSENSOR
    BLUM, LJ
    [J]. ENZYME AND MICROBIAL TECHNOLOGY, 1993, 15 (05) : 407 - 411
  • [5] DETERMINATION OF GLUCOSE IN WINE AND FRUIT JUICE BASED ON A FIBRE-OPTIC GLUCOSE BIOSENSOR ANF FLOW-INJECTION ANALYSIS
    DREMEL, BAA
    SCHAFFAR, BPH
    SCHMID, RD
    [J]. ANALYTICA CHIMICA ACTA, 1989, 225 (02) : 293 - 301
  • [6] Prussian blue-based optical glucose biosensor in flow-injection analysis
    Lenarczuk, T
    Wencel, D
    Glab, S
    Koncki, R
    [J]. ANALYTICA CHIMICA ACTA, 2001, 447 (1-2) : 23 - 32
  • [7] DETERMINATION OF GLUCOSE IN CLINICAL-SAMPLES BY FLOW REVERSAL FLOW-INJECTION ANALYSIS
    TOEI, J
    [J]. ANALYST, 1988, 113 (03) : 475 - 478
  • [8] An inexpensive biosensor for uric acid determination in human serum by flow-injection analysis
    Dutra, RF
    Moreira, KA
    Oliveira, MIP
    Araújo, AN
    Montenegro, MCBS
    Filho, JLL
    Silva, VL
    [J]. ELECTROANALYSIS, 2005, 17 (08) : 701 - 705
  • [9] A novel biamperometric biosensor for urinary oxalate determination using flow-injection analysis
    Milardovic, Stjepan
    Kerekovic, Irena
    Nodilo, Marijana
    [J]. TALANTA, 2008, 77 (01) : 222 - 228
  • [10] AN AMPEROMETRIC FLOW-INJECTION ANALYSIS BIOSENSOR FOR GLUCOSE BASED ON GRAPHITE PASTE MODIFIED WITH TETRACYANOQUINODIMETHANE
    PANDEY, PC
    GLAZIER, S
    WEETALL, HH
    [J]. ANALYTICAL BIOCHEMISTRY, 1993, 214 (01) : 233 - 237