DETERMINATION OF GLUCOSE IN DILUTED BLOOD WITH A THERMAL FLOW-INJECTION ANALYSIS BIOSENSOR

被引:6
|
作者
HARBORN, U
XIE, B
DANIELSSON, B
机构
[1] Department of Pure and Applied Biochemistry, Chemical Center, University of Lund, S-221 00
关键词
THERMAL BIOSENSOR; GLUCOSE OXIDASE; GLUCOSE; WHOLE BLOOD;
D O I
10.1080/00032719408005996
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The glucose concentration in diluted whole blood has been measured, using a miniaturized thermal biosensor based on the enzyme thermistor principle. The biosensor is a small flow injection system. A sample volume of 20 mu l is injected into a flow of 50 mu l/min. The heat produced when the sample passes the enzyme column is measured with a thermistor connected to a Wheatstone bridge. The enzyme column contains glucose oxidase and catalase co-immobilized on a solid support material. Samples of whole blood usually cause problems in flow-systems. The blood cells tend to block the enzyme column and the back pressure increases. We have tested a superporous agarose material as enzyme support material using tenfold diluted samples of whole human blood. The blood was collected from the finger-tip and diluted with buffer containing an anticoagulant and sodium fluoride. The number of samples possible to inject and the accuracy compared to the Boehringer Mannheim Reflolux have been determined. At least 100 ten-fold diluted blood samples could be injected on a micro-column of superporous agarose. The obtained glucose concentration correlated well with the one obtained with the reference instrument.
引用
收藏
页码:2639 / 2645
页数:7
相关论文
共 50 条
  • [21] DETERMINATION OF CLONAZEPAM BY FLOW-INJECTION ANALYSIS
    LATORRE, C
    BLANCO, MH
    ABAD, EL
    VICENTE, J
    HERNANDEZ, L
    [J]. ANALYST, 1988, 113 (02) : 317 - 319
  • [22] Determination of molybdenum by flow-injection analysis
    Barakat, SA
    Mahmoud, TY
    [J]. ACTA CHIMICA SLOVENICA, 2003, 50 (04) : 799 - 806
  • [23] FOOD ANALYSIS BY BIOSENSOR FLOW-INJECTION ANALYTICAL METHODS
    UKEDA, H
    [J]. JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 1995, 42 (10): : 849 - 858
  • [24] MULTIFUNCTIONAL FLOW-INJECTION BIOSENSOR FOR THE SIMULTANEOUS MEASUREMENT OF CREATININE, GLUCOSE, AND UREA
    RUI, CS
    OGAWA, HI
    SONOMOTO, K
    KATO, Y
    [J]. BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 1993, 57 (02) : 191 - 194
  • [25] Flow-injection determination of glucose by a photoinduced chemiluminescent reaction
    Pérez-Ruíz, T
    Martínez-Lozano, C
    Tomás, V
    Sanz, A
    [J]. ANALYTICAL LETTERS, 1998, 31 (11) : 1837 - 1855
  • [26] FLOW-INJECTION ANALYSIS WITH MEMBRANE SEPARATION - DETERMINATION OF AMMONIA IN BLOOD AND URINE
    AOKI, T
    UEMURA, S
    MUNEMORI, M
    [J]. BUNSEKI KAGAKU, 1984, 33 (10) : 505 - 509
  • [27] SEQUENTIAL DETERMINATION OF GLUCOSE AND FRUCTOSE IN FOODS BY FLOW-INJECTION ANALYSIS WITH IMMOBILIZED ENZYMES
    LINARES, P
    DECASTRO, MDL
    VALCARCEL, M
    [J]. ANALYTICA CHIMICA ACTA, 1987, 202 : 199 - 205
  • [28] SIMULTANEOUS DETERMINATION OF SUCROSE AND GLUCOSE IN MIXTURES BY FLOW-INJECTION ANALYSIS WITH IMMOBILIZED ENZYMES
    MASOOM, M
    TOWNSHEND, A
    [J]. ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) : 185 - 194
  • [29] AMPEROMETRIC FLOW-INJECTION BIOSENSOR SYSTEM FOR THE SIMULTANEOUS DETERMINATION OF UREA AND CREATININE
    RUI, CS
    SONOMOTO, K
    KATO, Y
    [J]. ANALYTICAL SCIENCES, 1992, 8 (06) : 845 - 850
  • [30] A MULTIFUNCTIONAL FLOW-INJECTION BIOSENSOR FOR THE SIMULTANEOUS DETERMINATION OF AMMONIA, CREATININE, AND UREA
    RUI, CS
    OGAWA, HI
    SONOMOTO, K
    KATO, Y
    [J]. ENZYME ENGINEERING XII, 1995, 750 : 30 - 38