Enzyme electrode for glucose determination in whole blood

被引:17
|
作者
Santoni, T
Santianni, D
Manzoni, A
Zanardi, S
Mascini, M
机构
[1] UNIV FLORENCE,DIPARTIMENTO SANITA PUBB EPIDEMIOL & CHEM ANALIT,I-50121 FLORENCE,ITALY
[2] INSTRUMENTAT LAB,I-20037 MILAN,ITALY
关键词
biosensors; glucose determination; glucose oxidase; gas permeable membranes;
D O I
10.1016/S0039-9140(96)02181-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a glucose sensor suitable for use with whole blood is described. It is based on anodic oxidation at + 700 mV of hydrogen peroxide with a platinum electrode covered with a gas permeable membrane. Glucose reacts with glucose oxidase immobilised on the external side of the membrane, and forms hydrogen peroxide which is able to cross the gas permeable membrane due to its high vapour tension, while other electroactive substances that are important interferents are completely blocked. This principle was discovered several years ago but no practical application was presented up to now. Therefore in this work a number of different commercial membranes were tested, in order to obtain a resistant, rapidly responding and interference free sensor to be used in conjunction with a blood gas measurement apparatus. Coimmobilisation of glucose oxidase and catalase was found to be useful for fast response and recovery of the electrode. Using some of the tested membranes, the linearity range is 1-15 mM, CV 5%, response time 90 s, recovery time for the next sample 120 s. The membrane's working life is 2-3 weeks. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1573 / 1580
页数:8
相关论文
共 50 条
  • [1] WHOLE-BLOOD GLUCOSE ENZYME ELECTRODE
    GENSHAW, MA
    JONES, JE
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (02) : 414 - 417
  • [2] WHOLE-BLOOD GLUCOSE ENZYME ELECTRODE
    GENSHAW, MA
    JONES, JE
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (8B) : C523 - C523
  • [3] ENZYME ELECTRODE FOR DETERMINING GLUCOSE IN WHOLE-BLOOD
    GENSHAW, MA
    [J]. CLINICAL CHEMISTRY, 1988, 34 (09) : 1717 - 1719
  • [4] DETERMINATION OF URATE IN UNDILUTED WHOLE-BLOOD BY ENZYME ELECTRODE
    KEEDY, FH
    VADGAMA, P
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (06): : 491 - 499
  • [5] ENZYME ELECTRODE FOR THE DETERMINATION OF GLUCOSE
    LOBEL, E
    RISHPON, J
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (01) : 51 - 53
  • [6] AN ENZYME ELECTRODE FOR DETERMINATION OF GLUCOSE
    ILCHEVA, L
    KOLUSHEVA, T
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 334 (07): : 623 - 623
  • [7] RAPID MEASUREMENTS OF AMYLASE AND GLUCOSE IN WHOLE-BLOOD USING AN ENZYME ELECTRODE
    YOSHINO, F
    OSAWA, H
    HARADA, K
    [J]. CLINICAL CHEMISTRY, 1981, 27 (06) : 1098 - 1098
  • [8] MEASURING OF GLUCOSE IN DILUTED WHOLE-BLOOD SAMPLES BY MEANS OF AN ENZYME ELECTRODE
    SCHELLER, F
    PFEIFFER, D
    KUHN, M
    HUNDERTMARK, J
    QUADE, A
    JANCHEN, M
    LANGE, G
    HOLESCH, H
    DITTMER, H
    [J]. ACTA BIOLOGICA ET MEDICA GERMANICA, 1980, 39 (06) : 671 - 679
  • [9] DESIGN CONSIDERATION OF AN IMMOBILIZED ENZYME ELECTRODE FOR THE MEASUREMENT OF GLUCOSE IN WHOLE-BLOOD
    FEISTAL, CC
    [J]. SELECTIVE ELECTRODE REVIEWS, 1988, 10 (01): : 46 - 46
  • [10] A BIOCOMPATIBLE ENZYME ELECTRODE FOR CONTINUOUS INVIVO GLUCOSE MONITORING IN WHOLE-BLOOD
    TURNER, RFB
    HARRISON, DJ
    RAJOTTE, RV
    BALTES, HP
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 561 - 564