Three-dimensional imaging of rumen tissue for morphometric analysis using micro-computed tomography

被引:11
|
作者
Steele, M. A. [1 ]
Garcia, F. [2 ]
Lowerison, M. [3 ]
Gordon, K. [4 ]
Metcalf, J. A. [1 ]
Hurtig, M. [2 ]
机构
[1] Nutreco Canada Agres, Guelph, ON N1G 4T2, Canada
[2] Univ Guelph, Ontario Vet Coll, Guelph, ON N1G 2W1, Canada
[3] Univ Calgary, Clin Res Unit, Fac Med, Calgary, AB T2N 1N4, Canada
[4] Univ Guelph, Sch Engn, Guelph, ON N1G 2W1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
development; morphology; micro-computed tomography; ADAPTATION;
D O I
10.3168/jds.2014-8374
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Rumen development in calves has been evaluated by measuring papillae length, width, and density using microscopy for over 50 yr. Although common in the literature, disadvantages to this method exist, such as large variations in rumen papillae size and shape, small numbers of total papillae being measured, and the time required. The objective of this study was to develop a more effective technique for assessing rumen papillae using micro-computed tomography (micro-CT) and to compare this technique with microscopy. Rumen tissue was collected from the ventral sac of 20 postweaned bull calves at 55 d of age, immediately fixed in 10% neutral buffered formalin for 48 h, and stored in 70% ethanol at 4 degrees C before the contrast enhancement. After evaluation of contrast-enhancement protocols, it was determined that mercury chloride provided the most pronounced contrast for accurate micro-CT imaging based on relative density of the papillae. A 1-cm(2) tissue section from the ventral sac of all bull calves was tensioned on a rapid prototyped curved plastic holder and imaged at 45 mu m resolution for 56 min using a GE Locus Explore micro-CT (General Electric, Milwaukee, WI). Micro View V2.2 software (General Electric) was used to create a 3-dimensional virtual model of the entire sample. The length and width of papillae were measured 3-dimensionally and compared with measurements of papillae under the light microscope taken from the same region. The length and width measurements using micro-CT (2.47 +/- 0.12 and 0.55 +/- 0.01mm) compared with light microscope (2.96 +/- 0.03 and 0.86 +/- 0.01 mm) were significantly smaller. The difference may reflect a more accurate determination in the base of the rumen tissue with micro-CT or the specificity of mercury chloride to bind only to intact rumen tissue. The mean number of papillae per centimeter squared viewed using micro-CT was 128.5 +/- 33.9 with a total surface area of 681.8 +/- 112.4 mm(2) and volume of 156 mm(3) per sample. Micro-CT data demonstrated that surface area and volume are positively associated and that papillae length was negatively associated with papillae per centimeter squared and positively associated with total volume of tissue section. This study represents the first time that micro-CT has been being used to assess morphology of rumen tissue. Micro-CT has the potential to improve the accuracy and efficiency of rumen tissue measurements; however, more standardization of each factor involved in tissue preparation, imaging, and location of papillae measurements is required.
引用
收藏
页码:7691 / 7696
页数:6
相关论文
共 50 条
  • [41] Three-dimensional analysis of maxillary first molar mesiobuccal root canal configuration and curvature using micro-computed tomography
    Park, Jong-Wook
    Lee, Jong-Ki
    Ha, Byung-Hyun
    Choi, Jeong-Ho
    Perinpanayagam, Hiran
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (03): : 437 - 442
  • [42] Reproducibility of Three-Dimensional Density Measurements in Teeth Using Micro-Computed Tomography: An Image Acquisition Protocol
    Huaiquin-Zuniga, Mary
    Castillo-Alonso, Camila
    Fonseca, Gabriel M.
    Lopez-Lazaro, Sandra
    APPLIED SCIENCES-BASEL, 2024, 14 (14):
  • [43] A novel three-dimensional analysis of standardized bone defects by means of confocal scanner and micro-computed tomography
    Clozza, Emanuele
    Obrecht, Marcel
    Dard, Michel
    Coelho, Paulo G.
    Dahlin, Christer
    Engebretson, Steven P.
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (04) : 1245 - 1250
  • [44] Three-dimensional characterization of cell clusters using synchrotron-radiation-based micro-computed tomography
    Müller, B
    Riedel, M
    Thurner, PJ
    MICROSCOPY AND MICROANALYSIS, 2006, 12 (02) : 97 - 105
  • [45] A novel three-dimensional analysis of standardized bone defects by means of confocal scanner and micro-computed tomography
    Emanuele Clozza
    Marcel Obrecht
    Michel Dard
    Paulo G. Coelho
    Christer Dahlin
    Steven P. Engebretson
    Clinical Oral Investigations, 2014, 18 : 1245 - 1250
  • [46] Construction of three-dimensional tooth model by micro-computed tomography and application for data sharing
    Kato, A.
    Ohno, N.
    CLINICAL ORAL INVESTIGATIONS, 2009, 13 (01) : 43 - 46
  • [47] Three-dimensional observation of the mouse embryo by micro-computed tomography: composition of the trigeminal ganglion
    Hidekazu Aoyagi
    Kohzo Tsuchikawa
    Shin-ichi Iwasaki
    Odontology, 2010, 98 : 26 - 30
  • [48] Three-dimensional observation of the mouse embryo by micro-computed tomography: composition of the trigeminal ganglion
    Aoyagi, Hidekazu
    Tsuchikawa, Kohzo
    Iwasaki, Shin-ichi
    ODONTOLOGY, 2010, 98 (01) : 26 - 30
  • [49] Three-dimensional microstructure of human alveolar trabecular bone: a micro-computed tomography study
    Lee, Ji-Hyun
    Kim, Hee-Jin
    Yun, Jeong-Ho
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2017, 47 (01): : 20 - 29
  • [50] Construction of three-dimensional tooth model by micro-computed tomography and application for data sharing
    A. Kato
    N. Ohno
    Clinical Oral Investigations, 2009, 13 : 43 - 46