Three-dimensional imaging of rumen tissue for morphometric analysis using micro-computed tomography

被引:11
|
作者
Steele, M. A. [1 ]
Garcia, F. [2 ]
Lowerison, M. [3 ]
Gordon, K. [4 ]
Metcalf, J. A. [1 ]
Hurtig, M. [2 ]
机构
[1] Nutreco Canada Agres, Guelph, ON N1G 4T2, Canada
[2] Univ Guelph, Ontario Vet Coll, Guelph, ON N1G 2W1, Canada
[3] Univ Calgary, Clin Res Unit, Fac Med, Calgary, AB T2N 1N4, Canada
[4] Univ Guelph, Sch Engn, Guelph, ON N1G 2W1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
development; morphology; micro-computed tomography; ADAPTATION;
D O I
10.3168/jds.2014-8374
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Rumen development in calves has been evaluated by measuring papillae length, width, and density using microscopy for over 50 yr. Although common in the literature, disadvantages to this method exist, such as large variations in rumen papillae size and shape, small numbers of total papillae being measured, and the time required. The objective of this study was to develop a more effective technique for assessing rumen papillae using micro-computed tomography (micro-CT) and to compare this technique with microscopy. Rumen tissue was collected from the ventral sac of 20 postweaned bull calves at 55 d of age, immediately fixed in 10% neutral buffered formalin for 48 h, and stored in 70% ethanol at 4 degrees C before the contrast enhancement. After evaluation of contrast-enhancement protocols, it was determined that mercury chloride provided the most pronounced contrast for accurate micro-CT imaging based on relative density of the papillae. A 1-cm(2) tissue section from the ventral sac of all bull calves was tensioned on a rapid prototyped curved plastic holder and imaged at 45 mu m resolution for 56 min using a GE Locus Explore micro-CT (General Electric, Milwaukee, WI). Micro View V2.2 software (General Electric) was used to create a 3-dimensional virtual model of the entire sample. The length and width of papillae were measured 3-dimensionally and compared with measurements of papillae under the light microscope taken from the same region. The length and width measurements using micro-CT (2.47 +/- 0.12 and 0.55 +/- 0.01mm) compared with light microscope (2.96 +/- 0.03 and 0.86 +/- 0.01 mm) were significantly smaller. The difference may reflect a more accurate determination in the base of the rumen tissue with micro-CT or the specificity of mercury chloride to bind only to intact rumen tissue. The mean number of papillae per centimeter squared viewed using micro-CT was 128.5 +/- 33.9 with a total surface area of 681.8 +/- 112.4 mm(2) and volume of 156 mm(3) per sample. Micro-CT data demonstrated that surface area and volume are positively associated and that papillae length was negatively associated with papillae per centimeter squared and positively associated with total volume of tissue section. This study represents the first time that micro-CT has been being used to assess morphology of rumen tissue. Micro-CT has the potential to improve the accuracy and efficiency of rumen tissue measurements; however, more standardization of each factor involved in tissue preparation, imaging, and location of papillae measurements is required.
引用
收藏
页码:7691 / 7696
页数:6
相关论文
共 50 条
  • [31] Three-dimensional structure of the orbicularis retaining ligament: an anatomical study using micro-computed tomography
    Jehoon O
    Hyun-Jin Kwon
    You-Jin Choi
    Tae-Hyeon Cho
    Hun-Mu Yang
    Scientific Reports, 8
  • [32] Three-dimensional micro-computed tomography analysis for spinal instability after lumbar facetectomy in the rat
    Daisuke Fukui
    Mamoru Kawakami
    Kevin Cheng
    Koichiro Murata
    Keianne Yamada
    Rinoka Sato
    Munehito Yoshida
    Hiroshi Yamada
    Nozomu Inoue
    Koichi Masuda
    European Spine Journal, 2017, 26 : 2014 - 2020
  • [33] Three-dimensional micro-computed tomography analysis for spinal instability after lumbar facetectomy in the rat
    Fukui, Daisuke
    Kawakami, Mamoru
    Cheng, Kevin
    Murata, Koichiro
    Yamada, Keianne
    Sato, Rinoka
    Yoshida, Munehito
    Yamada, Hiroshi
    Inoue, Nozomu
    Masuda, Koichi
    EUROPEAN SPINE JOURNAL, 2017, 26 (08) : 2014 - 2020
  • [34] Three-Dimensional In Vivo Imaging of the Murine Liver: A Micro-Computed Tomography-Based Anatomical Study
    Fiebig, Teresa
    Boll, Hanne
    Figueiredo, Giovanna
    Kerl, Hans Ulrich
    Nittka, Stefanie
    Groden, Christoph
    Kramer, Martin
    Brockmann, Marc A.
    PLOS ONE, 2012, 7 (02):
  • [35] Evaluation of three-dimensional image registration methodologies for in vivo micro-computed tomography
    Boyd, Steven K.
    Moser, Stephan
    Kuhn, Michael
    Klinck, Robert J.
    Krauze, Peter L.
    Mueller, Ralph
    Gasser, Juerg S.
    ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (10) : 1587 - 1599
  • [36] A new method for the quantification of aortic calcification by three-dimensional micro-computed tomography
    Huesa, C.
    Millan, J. L.
    van 't Hof, R. J.
    MacRae, V. E.
    INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE, 2013, 32 (05) : 1047 - 1050
  • [37] Three-dimensional characterization of metal foam structures via micro-computed tomography
    Illerhaus, B
    Goebbels, J
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2000, 31 (06) : 527 - 528
  • [38] Evaluation of Three-dimensional Image Registration Methodologies for In Vivo Micro-computed Tomography
    Steven K. Boyd
    Stephan Moser
    Michael Kuhn
    Robert J. Klinck
    Peter L. Krauze
    Ralph Müller
    Jürg A. Gasser
    Annals of Biomedical Engineering, 2006, 34 : 1587 - 1599
  • [39] Immunofluorescence-guided segmentation of three-dimensional features in micro-computed tomography datasets of human lung tissue
    Lawson, Matthew J.
    Katsamenis, Orestis L.
    Chatelet, David
    Alzetani, Aiman
    Larkin, Oliver
    Haig, Ian
    Lackie, Peter
    Warner, Jane
    Schneider, Philipp
    ROYAL SOCIETY OPEN SCIENCE, 2021, 8 (11):
  • [40] Morphological Analysis of Spherical Adsorptive Carbon Granules Using Three-Dimensional X-Ray Micro-computed Tomography
    Lzutsu, Ken-ichi
    Abe, Yasuhiro
    Yomota, Chikako
    Yoshid, Hiroyuki
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2020, 68 (02) : 179 - 180