Three-dimensional imaging of rumen tissue for morphometric analysis using micro-computed tomography

被引:11
|
作者
Steele, M. A. [1 ]
Garcia, F. [2 ]
Lowerison, M. [3 ]
Gordon, K. [4 ]
Metcalf, J. A. [1 ]
Hurtig, M. [2 ]
机构
[1] Nutreco Canada Agres, Guelph, ON N1G 4T2, Canada
[2] Univ Guelph, Ontario Vet Coll, Guelph, ON N1G 2W1, Canada
[3] Univ Calgary, Clin Res Unit, Fac Med, Calgary, AB T2N 1N4, Canada
[4] Univ Guelph, Sch Engn, Guelph, ON N1G 2W1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
development; morphology; micro-computed tomography; ADAPTATION;
D O I
10.3168/jds.2014-8374
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Rumen development in calves has been evaluated by measuring papillae length, width, and density using microscopy for over 50 yr. Although common in the literature, disadvantages to this method exist, such as large variations in rumen papillae size and shape, small numbers of total papillae being measured, and the time required. The objective of this study was to develop a more effective technique for assessing rumen papillae using micro-computed tomography (micro-CT) and to compare this technique with microscopy. Rumen tissue was collected from the ventral sac of 20 postweaned bull calves at 55 d of age, immediately fixed in 10% neutral buffered formalin for 48 h, and stored in 70% ethanol at 4 degrees C before the contrast enhancement. After evaluation of contrast-enhancement protocols, it was determined that mercury chloride provided the most pronounced contrast for accurate micro-CT imaging based on relative density of the papillae. A 1-cm(2) tissue section from the ventral sac of all bull calves was tensioned on a rapid prototyped curved plastic holder and imaged at 45 mu m resolution for 56 min using a GE Locus Explore micro-CT (General Electric, Milwaukee, WI). Micro View V2.2 software (General Electric) was used to create a 3-dimensional virtual model of the entire sample. The length and width of papillae were measured 3-dimensionally and compared with measurements of papillae under the light microscope taken from the same region. The length and width measurements using micro-CT (2.47 +/- 0.12 and 0.55 +/- 0.01mm) compared with light microscope (2.96 +/- 0.03 and 0.86 +/- 0.01 mm) were significantly smaller. The difference may reflect a more accurate determination in the base of the rumen tissue with micro-CT or the specificity of mercury chloride to bind only to intact rumen tissue. The mean number of papillae per centimeter squared viewed using micro-CT was 128.5 +/- 33.9 with a total surface area of 681.8 +/- 112.4 mm(2) and volume of 156 mm(3) per sample. Micro-CT data demonstrated that surface area and volume are positively associated and that papillae length was negatively associated with papillae per centimeter squared and positively associated with total volume of tissue section. This study represents the first time that micro-CT has been being used to assess morphology of rumen tissue. Micro-CT has the potential to improve the accuracy and efficiency of rumen tissue measurements; however, more standardization of each factor involved in tissue preparation, imaging, and location of papillae measurements is required.
引用
收藏
页码:7691 / 7696
页数:6
相关论文
共 50 条
  • [1] THREE-DIMENSIONAL MORPHOMETRIC ONTOGENY OF MOLLUSC SHELLS BY MICRO-COMPUTED TOMOGRAPHY AND GEOMETRIC ANALYSIS
    Monnet, Claude
    Zollikofer, Christoph
    Bucher, Hugo
    Goudemand, Nicolas
    PALAEONTOLOGIA ELECTRONICA, 2009, 12 (03)
  • [2] Micro-computed tomography studies for three-dimensional leather structure analysis
    20145100352428
    Meyndt, R., 1600, American Leather Chemists Association (109):
  • [3] MICRO-COMPUTED TOMOGRAPHY STUDIES FOR THREE-DIMENSIONAL LEATHER STRUCTURE ANALYSIS
    Bittrich, E.
    Schladitz, K.
    Meyndt, R.
    Schulz, H.
    Godehardt, M.
    JOURNAL OF THE AMERICAN LEATHER CHEMISTS ASSOCIATION, 2014, 109 (11): : 367 - 371
  • [4] Three-dimensional characterization of abrasive chips using micro-computed tomography
    Fang, Shiqi
    Fell, Jonas
    Frank, Alexander
    Guo, Yuebin
    Herrmann, Hans-Georg
    Baehre, Dirk
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2024, 133 (9-10): : 4651 - 4662
  • [5] Three-dimensional analysis of nonhuman primate trabecular architecture using micro-computed tomography
    Fajardo, RJ
    Müller, R
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2001, 115 (04) : 327 - 336
  • [6] Three-Dimensional Imaging of Hepatic Sinusoids in Mice Using Synchrotron Radiation Micro-Computed Tomography
    Yoon, Yae Jin
    Chang, Soeun
    Kim, Oh Youn
    Kang, Bo-Kyeong
    Park, Jaesung
    Lim, Jae-Hong
    Huang, Jung Yun
    Kim, Yoon-Keun
    Byun, Jae Ho
    Gho, Yong Song
    PLOS ONE, 2013, 8 (07):
  • [7] Three-dimensional micro-computed tomography of renal vasculature in rats
    GarciaSanz, A
    RodriguezBarbero, A
    Bentley, MD
    Ritman, EL
    Romero, JC
    HYPERTENSION, 1997, 30 (03) : P154 - P154
  • [8] Three-Dimensional Micro-Computed Tomography of the Adult Mouse Ovary
    Fiorentino, Giulia
    Parrilli, Annapaola
    Garagna, Silvia
    Zuccotti, Maurizio
    FRONTIERS IN CELL AND DEVELOPMENTAL BIOLOGY, 2020, 8
  • [9] Three-dimensional observation of mouse tongue muscles using micro-computed tomography
    Hidekazu Aoyagi
    Shin-ichi Iwasaki
    Kenzirou Nakamura
    Odontology, 2015, 103 : 1 - 8
  • [10] Three-dimensional observation of mouse tongue muscles using micro-computed tomography
    Aoyagi, Hidekazu
    Iwasaki, Shin-ichi
    Nakamura, Kenzirou
    ODONTOLOGY, 2015, 103 (01) : 1 - 8