High-precision measurement of tidal current structures using coastal acoustic tomography

被引:24
|
作者
Zhang, Chuanzheng [1 ]
Zhu, Xiao-Hua [1 ,3 ]
Zhu, Ze-Nan [1 ]
Liu, Wenhu [1 ]
Zhang, Zhongzhe [2 ]
Fan, Xiaopeng [1 ]
Zhao, Ruixiang [1 ]
Dong, Menghong [1 ]
Wang, Min [1 ]
机构
[1] State Ocean Adm, Inst Oceanog 2, State Key Lab Satellite Ocean Environm Dynam, Hangzhou 310012, Zhejiang, Peoples R China
[2] Dalian Ocean Univ, Coll Marine Sci & Environm, Dalian 116023, Peoples R China
[3] Zhejiang Univ, Ocean Coll, Zhoushan 316021, Peoples R China
基金
中国国家自然科学基金;
关键词
Coastal acoustic tomography; High precision; Tidal currents; Residual currents; Dalian bay; STRAIT; BAY;
D O I
10.1016/j.ecss.2017.05.014
中图分类号
Q17 [水生生物学];
学科分类号
071004 ;
摘要
A high-precision coastal acoustic tomography (CAT) experiment for reconstructing the current variation in Dalian Bay (DLB) was successfully conducted by 11 coastal acoustic tomography systems during March 7-8, 2015. The horizontal distributions of tidal currents and residual currents were mapped well by the inverse method, which used reciprocal travel time data along 51 successful sound transmission rays. The semi-diurnal tide is dominant in DLB, with a maximum speed of 0.69 m s(-1) at the eastern and southwestern parts near the bay mouth that gradually decreases toward the inner bay with an average velocity of 031 m s(-1). The residual current enters the observational domain from the two flanks of the bay mouth and flows out in the inner bay. One anticyclone and one cyclone were noted inside DLB as was one cyclone at the bay mouth. The maximum residual current in the observational domain reached 0.11 m s(-1), with a mean residual current of 0.03 m s(-1). The upper 15-m depth-averaged inverse velocities were in excellent agreement with the moored Acoustic Doppler Current Profiler (ADCP) at the center of the bay, with a root mean square difference (RMSD) of 0.04 m s(-1) for the eastward and northward components. The precision of the present tomography measurements was the highest thus far owing to the largest number of transmission rays ever recorded. Sensitivity experiments showed that the RMSD between CAT and moored-ADCP increased from 0.04 m s(-1) to 0.08 m s(-1) for both the eastward and northward velocities when reducing the number of transmission rays from 51 to 11. The observational accuracy was determined by the spatial resolution of acoustic ray in the CAT measurements. The cost optimal scheme consisted of 29 transmission rays with a spatial resolution of acoustic ray of 2.03 root km(2)/ray numbers. Moreover, a dynamic analysis of the residual currents showed that the horizontal pressure gradient of residual sea level and Coriolis force contribute 38.3% and 36.0%, respectively. This indicates that the two terms are the dominant factors of the residual currents in DLB. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:12 / 24
页数:13
相关论文
共 50 条
  • [21] HIGH-PRECISION MEASUREMENT BY HOLOGRAMMETRY
    WATSON, J
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1993, 35 (11): : 628 - 633
  • [23] Synchronous Assimilation of Tidal Current-Related Data Obtained Using Coastal Acoustic Tomography and High-Frequency Radar in the Xiangshan Bay, China
    Zhu, Ze-Nan
    Zhu, Xiao-Hua
    Guan, Weibing
    Zhang, Chuanzheng
    Chen, Minmo
    Liu, Zhao-Jun
    Wang, Min
    Zheng, Hua
    Chen, Juntian
    Dai, Longhao
    Cao, Zhenyi
    Chen, Qi
    Kaneko, Arata
    REMOTE SENSING, 2022, 14 (13)
  • [24] CMOS HIGH-SPEED, HIGH-PRECISION CURRENT CONVEYOR AND CURRENT FEEDBACK-AMPLIFIER STRUCTURES
    BRUUN, E
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1993, 74 (01) : 93 - 100
  • [25] High-precision wavelength measurement using a virtual Fizeau cavity
    Liu, Yixuan
    Ma, Shibang
    Yang, Kun
    Meng, Lingqiang
    Zong, Yi
    Li, Jianxin
    OPTICS LETTERS, 2023, 48 (24) : 6428 - 6431
  • [26] A High-Precision Algorithm for Phasor Measurement Using Mathematical Morphology
    Wang, Chao
    Wang, Fangzong
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [27] A high-precision weak current source using operational amplifiers
    Lei, Shengjie
    Wei, Zhiyong
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2012, 99 (06) : 761 - 775
  • [28] High-precision measurement of satellite velocity using the EISCAT radar
    Nygren, T.
    Markkanen, J.
    Aikio, A.
    Voiculescu, M.
    ANNALES GEOPHYSICAE, 2012, 30 (10) : 1555 - 1565
  • [29] High-precision neuron MOSFET structures
    Rantala, A
    Franssila, S
    Kaski, K
    Lampinen, J
    Åberg, M
    Kuivalainen, P
    ELECTRONICS LETTERS, 1999, 35 (02) : 155 - 157
  • [30] SIGNIFICANCE OF HIGH-PRECISION IN ENZYME STRUCTURES
    RAMANADHAM, M
    SIEKER, LC
    JENSEN, LH
    CURRENT SCIENCE, 1987, 56 (04): : 172 - 173