Experience with the wearable cardioverter-defibrillator in older patients: Results from the Prospective Registry of Patients Using the Wearable Cardioverter-Defibrillator

被引:12
|
作者
Daimee, Usama A. [1 ]
Vermilye, Katherine [1 ]
Moss, Arthur J. [1 ]
Goldenberg, Ilan [1 ]
Klein, Helmut U. [1 ]
McNitt, Scott [1 ]
Zareba, Wojciech [1 ]
Kutyifa, Valentina [1 ]
机构
[1] Univ Rochester, Med Ctr, Div Cardiol, Heart Res Follow Up Program, 265 Crittenden Blvd,Box 653, Rochester, NY 14642 USA
关键词
Compliance; Implantable cardioverter-defibrillator; Older patients; Ventricular tachyarrhythmias; Wearable cardioverter-defibrillator; ACUTELY TERMINATING EPISODES; HIGH-RISK; VENTRICULAR-FIBRILLATION; ATRIAL-FIBRILLATION; CLINICAL-EFFICACY; DYSFUNCTION; INFARCTION; THERAPY; SHOCKS;
D O I
10.1016/j.hrthm.2018.04.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Use of the wearable cardioverter-defibrillator (WCD) in older patients has not been described previously. OBJECTIVE The purpose of this study was to assess WCD wear time, risk of arrhythmic events during WCD use, and implantable cardioverter-defibrillator (ICD) implantation rates after the end of WCD use in patients with age >= 65 years vs <65 years. METHODS We stratified 1732 patients with ischemic and nonischemic cardiomyopathy from the Prospective Registry of Patients Using the Wearable Defibrillator Registry into 2 subgroups by age: those with age >= 65 years and those with age <65 years. Wear time, arrhythmic events, and end-of-use decisions, specifically ICD implantation or improvement in ejection fraction, were evaluated for each age group. RESULTS There were 722 patients with age >= 65 years (41.7%) and 1010 patients with age <65 years (58.3%). Daily WCD wear time was longer in the older population (median 22.8 h/d (IQR 21.5 23.2) vs 22.3 h/d (IQR 19.5- 23.0); P <.001). Patients with age >= 65 years experienced higher event rates, per 100 patient-years, for any sustained ventricular tachycardia/ventricular fibrillation (31.95 vs 9.82; P =.027) and ventricular tachycardia/ventricular fibrillation treated with WCD shock (6.92 vs 2.37; P =.034), particularly with ischemic cardiomyopathy. Younger patients experienced a trend toward a higher event rate for atrial arrhythmias with nonischemic cardiomyopathy (150.07 vs 74.86; P =.055). At the end of WCD use, ICD implantation was more frequent in older patients (41.8% vs 36.5%; P =.034). CONCLUSION Older patients had good compliance with the WCD, presented with more frequent ventricular arrhythmias, and were more likely to receive an ICD at the end of WCD use. The WCD may play a role in risk stratification of the older population.
引用
收藏
页码:1379 / 1386
页数:8
相关论文
共 50 条
  • [21] When Flatliners Meet the Wearable Cardioverter-Defibrillator
    Epstein, Andrew E.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (08) : 1340 - 1343
  • [22] Avoiding implantation of a cardioverter-defibrillator by bridging with wearable defibrillator vest
    Klein, Norbert
    Kuntz, Thomas
    Dhein, Stefan
    HERZ, 2021, 46 (02) : 172 - 177
  • [23] NATIONAL EXPERIENCE WITH WEARABLE CARDIOVERTER-DEFIBRILLATOR USE IN TAKOTSUBO CARDIOMYOPATHY
    Deeprasertkul, Peerawut
    Opreanu, Madalina
    Bianco, Nicole
    Thakur, Ranjan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E361 - E361
  • [24] Preventing premature implantable cardioverter defibrillator therapy (ICD) by using the wearable cardioverter-defibrillator (WCD)
    Waessnig, N.
    Guenther, M.
    Quick, S.
    Wiedemann, S.
    Heidrich, F.
    Sveric, K.
    Strasser, R.
    Ibrahim, K.
    Speiser, U.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1378 - 1378
  • [25] The wearable cardioverter-defibrillator is needed for most high-risk patients
    Lee, Byron K.
    HEART RHYTHM O2, 2020, 1 (03): : 227 - 229
  • [26] Patients with a wearable cardioverter-defibrillator (WCD) Prescription, function and rehabilitation support
    Schlitt, A.
    Guha, M.
    Noutsias, M.
    Klein, H. H.
    Klein, H. U.
    HERZ, 2019, 44 (05) : 379 - 389
  • [27] The wearable cardioverter-defibrillator is not needed for most high-risk patients
    Bhatt, Advay G.
    Mittal, Suneet
    HEART RHYTHM O2, 2020, 1 (03): : 230 - 233
  • [28] Economic Evaluation of the Wearable Cardioverter-Defibrillator in Patients After ICD Explantation
    Wan, Chingping
    Glad, Jo Ann
    Bianco, Nicole
    Szymkiewicz, Steven
    CIRCULATION, 2011, 124 (21)
  • [29] A Patch Wearable Cardioverter-Defibrillator for Patients at Risk of Sudden Cardiac Arrest
    Hummel, John
    Houmsse, Mahmoud
    Tomassoni, Gery
    Nair, Devi
    Romero, Jorge
    Hargrove, Joe
    Mathews, Kiran
    Thakkar, Anjali B.
    Ullery, Steven
    Eapen, Zubin J.
    Kumar, Uday N.
    Mehran, Roxana
    Butler, Javed
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (06) : 525 - 536
  • [30] Potential cost-effectiveness of wearable cardioverter-defibrillator for patients with implantable cardioverter-defibrillator explant in a high-income city of China
    Jiang, Xinchan
    Ming, Wai-Kit
    You, Joyce H. S.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2387 - 2396