Potential cost-effectiveness of wearable cardioverter-defibrillator for patients with implantable cardioverter-defibrillator explant in a high-income city of China

被引:7
|
作者
Jiang, Xinchan [1 ]
Ming, Wai-Kit [1 ]
You, Joyce H. S. [1 ]
机构
[1] Chinese Univ Hong Kong, Fac Med, Sch Pharm, Hong Kong, Peoples R China
关键词
China; cost-effectiveness; implantable cardioverter-defibrillator; sudden cardiac arrest; wearable cardioverter-defibrillator; SUDDEN-CARDIAC-DEATH; ARREST; REMOVAL;
D O I
10.1111/jce.14153
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Wearable cardioverter-defibrillator (WCD) is recommended for patients with implantable cardioverter-defibrillator (ICD) removal. This study aimed to investigate the potential cost-effectiveness of WCD for patients with ICD explant in a high-income city of China. Methods and Results A 5-year decision-analytic model was developed to simulate outcomes of three strategies during the period between ICD explant and reimplantation: discharge-to-home without WCD (home group), discharge-to-home with WCD (WCD group), and stay-in-hospital (hospital group). Outcome measures were mortality rates (during the period between ICD explant and reimplantation), direct medical costs, quality-adjusted life years (QALYs), and incremental cost per QALY saved (ICER). Model inputs were derived from literature and public data. Base-case analysis was performed at four cost levels of WCD. Robustness of model results was examined by sensitivity analyses. In base-case analysis, the 8-week mortality rates of WCD, hospital, and home groups were 7.3%, 8.1%, and 9.4%, respectively. WCD group gained the highest QALYs (3.0990 QALYs), followed by hospital group (3.0553 QALYs) and home group (3.0132 QALYs). The WCD group was the cost-effective option with ICERs less than willingness-to-pay (WTP) threshold (57 315 USD/QALY) at WCD daily cost <= USD48. In probabilistic sensitivity analysis, the WCD group at daily cost of USD24, USD48, USD72, and USD96 were cost-effective in 100%, 94.16%, 22.08%, and 0.16% of 10 000 Monte Carlo simulations, respectively. Conclusions Use of WCD during the period between ICD explant and reimplantation is likely to save life and gain higher QALYs. Cost-effectiveness of WCD is highly subject to the daily cost of WCD in China.
引用
收藏
页码:2387 / 2396
页数:10
相关论文
共 50 条
  • [1] Cost-effectiveness of implantable cardioverter-defibrillator
    不详
    HEART RHYTHM, 2006, 3 (01) : 126 - 126
  • [2] COST-EFFECTIVENESS OF THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    DELISSOVOY, G
    GUARNIERI, T
    PROGRESS IN CARDIOVASCULAR DISEASES, 1993, 36 (03) : 209 - 213
  • [3] COST-EFFECTIVENESS OF WEARABLE CARDIOVERTER-DEFIBRILLATOR IN CHINA: A DECISION ANALYSIS
    Jiang, X.
    Ming, W. K.
    You, J.
    VALUE IN HEALTH, 2019, 22 : S547 - S547
  • [4] Wearable cardioverter-defibrillator for prevention of sudden cardiac death after infected implantable cardioverter-defibrillator removal: A cost-effectiveness evaluation
    Healy, Christopher A.
    Carrillo, Roger G.
    HEART RHYTHM, 2015, 12 (07) : 1565 - 1573
  • [5] EVALUATING AND IMPROVING THE COST-EFFECTIVENESS OF THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    KUPERSMITH, J
    HOGAN, A
    GUERRERO, P
    GARDINER, J
    MELLITS, ED
    BAUMGARDNER, R
    ROVNER, D
    HOLMESROVNER, M
    MCLANE, A
    LEVINE, J
    SAKSENA, S
    GRIFFITH, L
    AMERICAN HEART JOURNAL, 1995, 130 (03) : 507 - 515
  • [6] IMPROVING COST-EFFECTIVENESS OF THE TRANSVENOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    GUERRERO, P
    HOGAN, A
    GARDINER, J
    MELLITS, ED
    BAUMGARDNER, RA
    ROVNER, D
    HOLMESROVNER, M
    MCLANE, A
    LEVINE, J
    SAKSENA, S
    GRIFFITH, L
    KUPERSMITH, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A206 - A206
  • [7] The implantable cardioverter-defibrillator
    Raj, SR
    Sheldon, RS
    PROGRESS IN CARDIOVASCULAR DISEASES, 2001, 44 (03) : 169 - 194
  • [8] The implantable cardioverter-defibrillator
    Groh, WJ
    Foreman, LD
    Zipes, DP
    AMERICAN FAMILY PHYSICIAN, 1998, 57 (02) : 310 - 312
  • [9] The implantable cardioverter-defibrillator
    Greene, HL
    CLINICAL CARDIOLOGY, 2000, 23 (05) : 315 - 326
  • [10] Risk stratification for implantable cardioverter defibrillator therapy: the role of the wearable cardioverter-defibrillator
    Klein, Helmut U.
    Goldenberg, Ilan
    Moss, Arthur J.
    EUROPEAN HEART JOURNAL, 2013, 34 (29) : 2230 - 2242