Spectrometry of linear energy transfer with a track etched detector

被引:4
|
作者
Spurny, F [1 ]
Bednar, J [1 ]
Turek, K [1 ]
机构
[1] Acad Sci Czech Republ, Inst Nucl Phys, Dept Radiat Dosimetry, Prague 18086 8, Czech Republic
关键词
linear energy transfer; microdosimetry; track etch detectors; polyallyldiglycolcarbonate; track parameters measurements; automatic image analyzer;
D O I
10.1016/S1350-4487(97)00130-3
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Etchable track formation in a track etch detector is a process directly related to the density of energy deposition by a charged particle in the detector. The analysis of track parameters would therefore permit to determine the linear energy transfer (LET) of a particle and its spectra in exposed track detectors. The contribution describes the method of LET Spectrometry based on the track parameter analysis in chemically etched polyallyldiglycolcarbonate. It is founded on the etch rates ratios determination using an automatic image analyzer, the calibration had been performed by heavy charged particles. The range of etch rate ratios established corresponded to the LET in tissue between 100 and 6000 MeV.cm(2).g(-1). The method was tested in the field of a Cf-252 neutron source, the LET spectra established in some other beams and fields are also presented.
引用
收藏
页码:515 / 518
页数:4
相关论文
共 50 条
  • [41] ENERGY THRESHOLD FOR NEUTRON DETECTION IN A MAKROFOL DIELECTRIC TRACK DETECTOR
    JOZEFOWICZ, K
    NUCLEAR INSTRUMENTS & METHODS, 1971, 93 (02): : 369 - +
  • [42] Nanochannels in track-etched membranes
    Pépy, G
    Balanzat, E
    Jean, B
    Kuklin, A
    Sertova, N
    Toulemonde, M
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2003, 36 (01) : 649 - 651
  • [43] Etched track profiles for relativistic 7 GeV silicon and 17.48 GeV Nickel ions in PADC detector: The case study of convex track walls
    Fromm, M.
    Abu-Shady, M.
    Groetz, J. E.
    Awad, E. M.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 187
  • [44] Nuclear Track Detector Characterization via Alpha-Spectrometry for Radioprotection Use
    Morelli, D.
    Imme, G.
    Aranzulla, M.
    Tazzer, A. L. Rosselli
    Catalano, R.
    Mangano, G.
    APPLICATIONS OF NUCLEAR TECHNIQUES: ELEVENTH INTERNATIONAL CONFERENCE, 2011, 1412
  • [45] THE ABSORPTION OF UV ENERGY IN THE DAMAGED REGION OF A PLASTIC TRACK DETECTOR
    BUKHARI, KM
    AKBER, RA
    HUSSAIN, G
    KHAN, HA
    RADIATION PHYSICS AND CHEMISTRY, 1980, 16 (05): : 385 - 388
  • [46] Radiation resistance of track etched membranes
    Buczkowski, M
    Sartowska, B
    Wawszczak, D
    Starosta, W
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 597 - 599
  • [47] Selective radiography with etched track detectors
    Skvarc, J
    Ilic, R
    Yanagië, H
    Rant, J
    Ogura, K
    Kobayashi, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 152 (01): : 115 - 121
  • [49] Modelling of linear energy transfer effects on track core processes in the radiolysis of water up to 300 °C
    Swiatla-Wojcik, D
    Buxton, GV
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1998, 94 (15): : 2135 - 2141
  • [50] Selective radiography with etched track detectors
    Skvarč, J.
    Ilić, R.
    Yanagië, H.
    Rant, J.
    Ogura, K.
    Kobayashi, H.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1999, 152 (01): : 115 - 121