Spectrometry of linear energy transfer with a track etched detector

被引:4
|
作者
Spurny, F [1 ]
Bednar, J [1 ]
Turek, K [1 ]
机构
[1] Acad Sci Czech Republ, Inst Nucl Phys, Dept Radiat Dosimetry, Prague 18086 8, Czech Republic
关键词
linear energy transfer; microdosimetry; track etch detectors; polyallyldiglycolcarbonate; track parameters measurements; automatic image analyzer;
D O I
10.1016/S1350-4487(97)00130-3
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Etchable track formation in a track etch detector is a process directly related to the density of energy deposition by a charged particle in the detector. The analysis of track parameters would therefore permit to determine the linear energy transfer (LET) of a particle and its spectra in exposed track detectors. The contribution describes the method of LET Spectrometry based on the track parameter analysis in chemically etched polyallyldiglycolcarbonate. It is founded on the etch rates ratios determination using an automatic image analyzer, the calibration had been performed by heavy charged particles. The range of etch rate ratios established corresponded to the LET in tissue between 100 and 6000 MeV.cm(2).g(-1). The method was tested in the field of a Cf-252 neutron source, the LET spectra established in some other beams and fields are also presented.
引用
收藏
页码:515 / 518
页数:4
相关论文
共 50 条
  • [21] Electric energy generation in single track-etched nanopores
    Xie, Yanbo
    Wang, Xinwei
    Xue, Jianming
    Jin, Ke
    Chen, Long
    Wang, Yugang
    APPLIED PHYSICS LETTERS, 2008, 93 (16)
  • [22] Energy discrimination by shape selection in etched track detection technique
    Tam, NC
    Baricza, K
    Lakosi, L
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 339 - 342
  • [23] Spectrometry of the LET with track etched detectors - correlation with proportional counter measured spectra
    Spurny, F
    Bottollier-Depois, JF
    Vlcek, B
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 193 - 197
  • [24] Neutron track detector for photo neutron measurements from high energy medical linear accelerator
    Cyriac, S.
    Kummali, A.
    Mm, M.
    Raman, G. R.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S150 - S150
  • [25] Spectrometry of Linear Energy Transfer and Its Use in High-Energy Particle Beams
    Jadrnickova, I.
    Spurny, F.
    Molokanov, A. G.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2008, 5 (06) : 531 - 537
  • [26] Comment on 'An etched track detector for short-term screening measurements of radon' Reply
    Ibrahimi, Z-F
    Miles, J. C. H.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2009, 29 (03) : 450 - 451
  • [27] Spectrometry of linear energy transfer and dosimetry measurements onboard spacecrafts and aircrafts
    Spurný F.
    Ploc O.
    Jadrníčková I.
    Physics of Particles and Nuclei Letters, 2009, 6 (1) : 70 - 77
  • [28] Proposed linear energy transfer areal detector for protons using radiochromic film
    Mayer, Rulon
    Lin, Liyong
    Fager, Marcus
    Douglas, Dan
    McDonough, James
    Carabe, Alejandro
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (04):
  • [29] Effect of soil and sand moisture content on radon diffusion using plastic track etched detector
    Singh, B
    Virk, HS
    RADIATION MEASUREMENTS, 1996, 26 (01) : 49 - 50
  • [30] A neutron track etch detector for electron linear accelerators in radiotherapy
    Vukovic, Branko
    Faj, Dario
    Poje, Marina
    Varga, Maja
    Radolic, Vanja
    Miklavcic, Igor
    Ivkovic, Ana
    Planinic, Josip
    RADIOLOGY AND ONCOLOGY, 2010, 44 (01) : 62 - 66