Spectrometry of linear energy transfer with a track etched detector

被引:4
|
作者
Spurny, F [1 ]
Bednar, J [1 ]
Turek, K [1 ]
机构
[1] Acad Sci Czech Republ, Inst Nucl Phys, Dept Radiat Dosimetry, Prague 18086 8, Czech Republic
关键词
linear energy transfer; microdosimetry; track etch detectors; polyallyldiglycolcarbonate; track parameters measurements; automatic image analyzer;
D O I
10.1016/S1350-4487(97)00130-3
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Etchable track formation in a track etch detector is a process directly related to the density of energy deposition by a charged particle in the detector. The analysis of track parameters would therefore permit to determine the linear energy transfer (LET) of a particle and its spectra in exposed track detectors. The contribution describes the method of LET Spectrometry based on the track parameter analysis in chemically etched polyallyldiglycolcarbonate. It is founded on the etch rates ratios determination using an automatic image analyzer, the calibration had been performed by heavy charged particles. The range of etch rate ratios established corresponded to the LET in tissue between 100 and 6000 MeV.cm(2).g(-1). The method was tested in the field of a Cf-252 neutron source, the LET spectra established in some other beams and fields are also presented.
引用
收藏
页码:515 / 518
页数:4
相关论文
共 50 条
  • [1] Spectrometry of linear energy transfer with track etched detectors
    Spurny, F
    Molokanov, AG
    Vlcek, B
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 519 - 520
  • [2] SPECTROMETRY OF LINEAR ENERGY TRANSFER WITH TRACK-ETCHED DETECTORS IN CARBON ION BEAMS, MONO AND SOBP
    Brabcova, K. Pachnerova
    Ambrozova, I.
    Spurny, F.
    RADIATION PROTECTION DOSIMETRY, 2011, 143 (2-4) : 440 - 444
  • [3] Uncertainties in linear energy transfer spectra measured with track-etched detectors in space
    Brabcova, Katerina Pachnerova
    Ambrozova, Iva
    Koliskova, Zlata
    Malusek, Alexandr
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 713 : 5 - 10
  • [4] ETCHED-TRACK DETECTOR FOR NEUTRONS
    BECKER, RL
    ANTAL, JJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (12): : 1418 - &
  • [5] CALIBRATION OF A POLYCARBONATE ETCHED TRACK DETECTOR
    VANMARCKE, H
    TOYE, A
    OBERSTEDT, S
    RADIATION PROTECTION DOSIMETRY, 1994, 56 (1-4) : 239 - 240
  • [6] ENERGY SPECTROMETRY OF PROTONS BY MEANS OF A DIELECTRIC TRACK DETECTOR
    LUCK, HB
    NUCLEAR INSTRUMENTS & METHODS, 1974, 119 (02): : 403 - 404
  • [7] ETCHED TRACK PARAMETERS AND TRACK REGISTRATION EFFICIENCIES OF HOSTAPHAN PLASTIC DETECTOR
    KHAN, HA
    KHAN, NA
    BRANDT, R
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1984, 35 (07): : 607 - 610
  • [8] LINEAR-ENERGY-TRANSFER AND TRACK STRUCTURE
    KRAFT, G
    KRAMER, M
    ADVANCES IN RADIATION BIOLOGY, VOL 17, 1993, 17 : 1 - 52
  • [9] To the spectrometry of linear energy transfer in charged particle beams by means of track-etch detectors
    Jadrnickova, Iva
    Spurny, Frantisek
    RADIATION MEASUREMENTS, 2008, 43 : S191 - S194
  • [10] Estimation of indoor radon levels using etched track detector
    El-Badry, Basma A.
    Al-Naggar, Tayseer, I
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2018, 11 (04) : 355 - 360