Investigation of the Imaging Polarization Effect Based on a Pixellated CdZnTe Detector

被引:5
|
作者
Li Miao [1 ]
Xiao Sha-Li [1 ]
Zhang Liu-Qiang [1 ]
Cao Yu-Lin [2 ]
Chen Yu-Xiao [2 ]
Shen Min [1 ]
Wang Xi [1 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Optoelect Technol & Syst, Chongqing 400030, Peoples R China
[2] China Acad Engn Phys, Inst Elect Engn, Mianyang 621900, Peoples R China
关键词
SPECTRA; CDTE;
D O I
10.1088/0256-307X/27/7/070702
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A pixel array CdZnTe imaging system, employing a 40 x 40 x 5 mm(3) pixellated CdZnTe detector, is established. The imaging polarization effect in the CdZnTe pixellated detector for a collimated Cs(137) Gamma source is investigated in detail. The experimental results for different irradiated fluxes indicate that excessive irradiated flux indeed causes central pixels to be shut off completely. The imaging performance of the polarized detector is severely degraded. Polarized detector counts are simultaneously reduced to one-third of the non-polarized detector counts. A theoretical model of potential distribution is also proposed by solving the Poisson equation and, in turn, the electric potential distortion for high irradiated flux is discussed by comparison with the experimental results.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] A test device for isotopic γ-ray imaging with CdZnTe detector
    HUANG Jin1 WANG Xiaolian2* ZENG Hui2 XU Zizong2 (1Special Class for the Gifted Young
    2Department of Modern Physics
    Nuclear Science and Techniques, 2007, (02) : 107 - 110
  • [32] CdZnTe strip detector for arc second imaging and spectroscopy
    Stahle, CM
    Parsons, A
    Bartlett, LM
    Kurczynski, P
    Krizmanic, JF
    Barbier, LM
    Barthelmy, SD
    Birsa, F
    Gehrels, N
    Odom, J
    Palmer, D
    Sappington, C
    Shu, P
    Teegarden, BJ
    Tueller, J
    HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 : 74 - 84
  • [33] A test device for isotopic γ-ray imaging with CdZnTe detector
    Huang Jin
    Wang Xiaolian
    Zeng Hui
    Xu Zizong
    NUCLEAR SCIENCE AND TECHNIQUES, 2007, 18 (02) : 107 - 110
  • [34] Investigation on electrical transport properties of CdZnTe pixel detector
    Nan Rui-Hua
    Wang Peng-Fei
    Jian Zeng-Yun
    Li Xiao-Juan
    ACTA PHYSICA SINICA, 2017, 66 (20)
  • [35] Pixellated NaI (T1) detector for light yield nonproportionality investigation
    Mengesha, W.
    Bowden, N. S.
    Allen, M.
    Lund, J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1830 - 1835
  • [36] Reliability of Pixellated CZT Detector Modules Used for Medical Imaging and Homeland Security
    Chen, H.
    Awadalla, S. A.
    Harris, F.
    Lu, P. H.
    Bindley, G.
    Lenos, H.
    Cardoso, B.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS X, 2008, 7079
  • [37] De-polarization of a CdZnTe radiation detector by pulsed infrared light
    Dedic, V.
    Franc, J.
    Rejhon, M.
    Grill, R.
    Zazvorka, J.
    Sellin, P. J.
    APPLIED PHYSICS LETTERS, 2015, 107 (03)
  • [38] Optimization of K-Edge Subtraction Imaging Using a Pixellated Spectroscopic Detector
    Pani, Silvia
    Saifuddin, Sarene C.
    Ferreira, Filipa I. M.
    Scuffham, James W.
    Stratmann, Philipp
    Wilson, Matthew D.
    Veale, Matthew C.
    Bell, Steven
    Seller, Paul
    Sellin, Paul J.
    Cernik, Robert J.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3063 - 3066
  • [39] Detailed modelling of pixellated CdZnTe detectors for an accurate performance characterization of a multi-modality imaging system
    Guerra, Pedro
    Kontaxakis, George
    Visvikis, Dimitris
    Santos, Andres
    Darambara, Dimitra G.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1924 - 1928
  • [40] A computed tomographic CdZnTe based scanning detector
    Giakos, GC
    Guntupalli, RK
    Vedantham, S
    Chowdhury, S
    Pillai, B
    WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 462 - 465