Optimization of K-Edge Subtraction Imaging Using a Pixellated Spectroscopic Detector

被引:0
|
作者
Pani, Silvia [1 ]
Saifuddin, Sarene C. [1 ]
Ferreira, Filipa I. M. [1 ]
Scuffham, James W. [2 ]
Stratmann, Philipp [1 ,4 ]
Wilson, Matthew D. [3 ]
Veale, Matthew C. [3 ]
Bell, Steven [3 ]
Seller, Paul [3 ]
Sellin, Paul J. [1 ]
Cernik, Robert J.
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 7KH, Surrey, England
[2] Royal Surrey County Hosp, Dept Nucl Med, Guildford, Surrey, England
[3] STFC Rutherford Appleton Lab, Didcot, Oxon, England
[4] Rhein Westfal TH Aachen, Aachen, Germany
基金
英国工程与自然科学研究理事会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conventional K-edge subtraction imaging is based around the acquisition of two separate images at energies respectively below and above the K-edge of a contrast agent. This implies increased patient dose with respect to a conventional procedure and potentially incorrect image registration due to patient motion. We present results obtained with a pixellated spectroscopic CdTe detector. A spectroscopic detector allows simultaneous acquisition of the two images by integrating appropriate bands from the transmitted X-ray spectrum, thus removing the above limitations; the photon counting capability of the detector limits the noise to statistical noise, thus minimizing the dose for a given signal-to-noise ratio. Furthermore, an appropriate choice of the integration bands allows optimization of image quality, resulting from a trade-off between background removal (maximum with a narrow band) and low statistical noise (achieved with a broad band). Results obtained with a custom test-object, simulating breast structures, and with an iodine-based contrast agent, are presented for two different image subtraction algorithms: logarithmic subtraction and dual-energy linear combination. Whilst being conceptually simpler, logarithmic subtraction is strongly dependent upon the position and width of the band selected, while linear combination allows better background removal even with a broad energy band, and therefore better image quality.
引用
收藏
页码:3063 / 3066
页数:4
相关论文
共 50 条
  • [1] K-edge subtraction imaging using a pixellated energy-resolving detector
    Pani, Silvia
    Saifuddin, Sarene C.
    Christodoulou, Christiana
    Veale, Matthew
    Seller, Paul
    Speller, Robert D.
    Wilson, Matthew
    Scuffham, James W.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [2] Spectral K-edge subtraction imaging
    Zhu, Y.
    Samadi, N.
    Martinson, M.
    Bassey, B.
    Wei, Z.
    Belev, G.
    Chapman, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (10): : 2485 - 2503
  • [3] An Optimized K-Edge Signal Extraction Method for K-Edge Decomposition Imaging Using a Photon Counting Detector
    Zhang, Zhidu
    Zhang, Xiaomei
    Hu, Jinming
    Xu, Qiong
    Li, Mohan
    Wei, Cunfeng
    Wei, Long
    Wang, Zhe
    FRONTIERS IN PHYSICS, 2021, 8
  • [4] K-edge subtraction using an energy-resolving position-sensitive detector
    Gillam, John E.
    Kitcher, Daniel
    Beveridge, Toby E.
    Midgley, Stewart
    Hall, Chris
    Lewis, Rob A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 97 - 100
  • [5] Comparison of iodine K-edge subtraction and fluorescence subtraction imaging in an animal system
    Zhang, H.
    Zhu, Y.
    Bewer, B.
    Zhang, L.
    Korbas, M.
    Pickering, I. J.
    George, G. N.
    Gupta, M.
    Chapman, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 594 (02): : 283 - 291
  • [6] K-edge subtraction imaging for angiography at a compact synchrotron source
    Kulpe, Stephanie
    Dierolf, Martin
    Braig, Eva-Maria
    Guenther, Benedikt
    Achterhold, Klaus
    Gleich, Bernhard
    Herzen, Julia
    Rummeny, Ernst
    Pfeiffer, Franz
    Pfeiffer, Daniela
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VII, 2019, 11110
  • [7] DIGITAL K-EDGE SUBTRACTION RADIOGRAPHY
    KRUGER, RA
    MISTRETTA, CA
    CRUMMY, AB
    SACKETT, JF
    GOODSITT, MM
    RIEDERER, SJ
    HOUK, TL
    SHAW, CG
    FLEMING, D
    RADIOLOGY, 1977, 125 (01) : 243 - 245
  • [8] Optimization of K-edge imaging with spectral CT
    He, Peng
    Wei, Biao
    Cong, Wenxiang
    Wang, Ge
    MEDICAL PHYSICS, 2012, 39 (11) : 6572 - 6579
  • [9] IODINE K-EDGE DUAL-ENERGY IMAGING FOR SUBTRACTION ANGIOGRAPHY USING SYNCHROTRON RADIATION AND A 2-DIMENSIONAL DETECTOR
    UMETANI, K
    UEDA, K
    TAKEDA, T
    AKISADA, M
    NAKAJIMA, T
    ANNO, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 301 (03): : 579 - 588
  • [10] Spectrum Optimization in Photon Counting Detector Based Iodine K-Edge CT Imaging
    Feng, Mang
    Ji, Xu
    Treb, Kevin
    Zhang, Ran
    Chen, Guang-Hong
    Li, Ke
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948