Optimization of K-Edge Subtraction Imaging Using a Pixellated Spectroscopic Detector

被引:0
|
作者
Pani, Silvia [1 ]
Saifuddin, Sarene C. [1 ]
Ferreira, Filipa I. M. [1 ]
Scuffham, James W. [2 ]
Stratmann, Philipp [1 ,4 ]
Wilson, Matthew D. [3 ]
Veale, Matthew C. [3 ]
Bell, Steven [3 ]
Seller, Paul [3 ]
Sellin, Paul J. [1 ]
Cernik, Robert J.
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 7KH, Surrey, England
[2] Royal Surrey County Hosp, Dept Nucl Med, Guildford, Surrey, England
[3] STFC Rutherford Appleton Lab, Didcot, Oxon, England
[4] Rhein Westfal TH Aachen, Aachen, Germany
基金
英国工程与自然科学研究理事会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conventional K-edge subtraction imaging is based around the acquisition of two separate images at energies respectively below and above the K-edge of a contrast agent. This implies increased patient dose with respect to a conventional procedure and potentially incorrect image registration due to patient motion. We present results obtained with a pixellated spectroscopic CdTe detector. A spectroscopic detector allows simultaneous acquisition of the two images by integrating appropriate bands from the transmitted X-ray spectrum, thus removing the above limitations; the photon counting capability of the detector limits the noise to statistical noise, thus minimizing the dose for a given signal-to-noise ratio. Furthermore, an appropriate choice of the integration bands allows optimization of image quality, resulting from a trade-off between background removal (maximum with a narrow band) and low statistical noise (achieved with a broad band). Results obtained with a custom test-object, simulating breast structures, and with an iodine-based contrast agent, are presented for two different image subtraction algorithms: logarithmic subtraction and dual-energy linear combination. Whilst being conceptually simpler, logarithmic subtraction is strongly dependent upon the position and width of the band selected, while linear combination allows better background removal even with a broad energy band, and therefore better image quality.
引用
收藏
页码:3063 / 3066
页数:4
相关论文
共 50 条
  • [11] Development of a combined K-edge subtraction and fluorescence subtraction imaging system for small animals
    Bewer, Brian
    Zhang, Honglin
    Zhu, Ying
    Zhang, Limei
    George, Graham N.
    Pickering, Ingrid J.
    Chapman, Dean
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (08):
  • [12] Synchrotron K-edge subtraction imaging and its application to metallic foams
    Zhang Qiang
    Toda, Hiroyuki
    ACTA PHYSICA SINICA, 2011, 60 (11)
  • [13] Element Identification by K-Edge Imaging Using Spectroscopic Photon Counting Detectors
    Schutz, Michael K.
    Fey, Julian
    Procz, Simon
    Useche, Juan S.
    Roque, Gerardo
    Fiederle, Michael
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (01) : 106 - 112
  • [14] Simultaneous Acquisition of K-Edge Subtraction Images using a pnCCD
    Nurdan, K.
    Nurdan, T. Conka
    AlTaani, M.
    Yousef, H.
    Walenta, A. H.
    Walenta, K.
    Abboud, A.
    Nasr, A.
    Ruebsamen, O.
    Schenk, W.
    Pietsch, U.
    Send, S.
    Hartmann, R.
    Leitenberger, W.
    Strueder, L.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3240 - +
  • [15] K-EDGE SUBTRACTION USING SYNCHROTRON RADIATION FOR CORONARY ANGIOGRAPHY
    AKISADA, M
    APPLIED RADIATION AND ISOTOPES, 1986, 37 (01) : 91 - 92
  • [16] Quantitative analysis of the effect of energy separation in k-edge digital subtraction imaging
    Sarnelli, A.
    Taibi, A.
    Baldelli, P.
    Gambaccini, M.
    Bravin, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11): : 3015 - 3026
  • [17] REAL-TIME K-EDGE SUBTRACTION X-RAY-IMAGING
    FUKAGAWA, H
    NODA, C
    SUZUKI, Y
    HASEGAWA, S
    ANDO, M
    HYODO, K
    NISHIMURA, K
    AKISADA, M
    TAKENAKA, E
    HOSAKA, R
    TOYOFUKU, F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2268 - 2271
  • [18] ANIMAL-EXPERIMENTS BY K-EDGE SUBTRACTION ANGIOGRAPHY BY USING SR
    ANNO, I
    AKISADA, M
    TAKEDA, T
    SUGISHITA, Y
    KAKIHANA, M
    OHTSUKA, S
    NISHIMURA, K
    HASEGAWA, S
    TAKENAKA, E
    HYODO, K
    ANDO, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2330 - 2331
  • [19] Crossover artifact in X-ray focusing imaging systems: K-edge subtraction imaging
    Bassey, B.
    Samadi, N.
    Panahifar, A.
    Cooper, D. M. L.
    Chapman, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 910 : 26 - 34
  • [20] Imaging and spectroscopic performance studies of pixellated CdTe Timepix detector
    Maneuski, D.
    Astromskas, V.
    Frojdh, E.
    Frojdh, C.
    Gimenez, E. N.
    Marchal, J.
    O'Shea, V.
    Stewart, G.
    Tartoni, N.
    Wilhelm, H.
    Wraight, K.
    Zain, R. M.
    JOURNAL OF INSTRUMENTATION, 2012, 7