Evaluation of four point-of-care meters for rapid determination of blood lactate concentrations in dogs

被引:31
|
作者
Acierno, Mark J. [1 ]
Mitchell, Mark A. [1 ]
机构
[1] Louisiana State Univ, Sch Vet Med, Dept Vet Clin Sci, Baton Rouge, LA 70810 USA
关键词
D O I
10.2460/javma.230.9.1315
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To determine whether blood lactate values determined in dogs with 4 commercially available point-of-care meters were in agreement with values determined with a critical care laboratory blood analyzer. Design-Prospective study. Animals-50 dogs evaluated for emergency treatment. Procedures-Blood samples were collected at initial evaluation and processed on 4 point-of-care meters and on a critical care laboratory blood analyzer. Results-All 4 point-of-care lactate meters generated measurements that were in agreement with the hospital's critical care analyzer. Values for agreement (bias) between the 4 point-of-care meters and the critical care analyzer were -0.652 (limits of agreement [LA], -1.958 to 0.6541), -0.670 (LA, -2.110 to 0.769), -0.096 (LA, -2.071 to 1.879), and -0.498 (LA, -2.616 to 1.620), respectively. Conclusions and Clinical Relevance-Despite its prognostic and therapeutic relevance, blood lactate measurement in dogs has been hampered by the inability to perform the test in a timely fashion. Results of the present study indicated that several handheld point-of-care lactate meters provided results that were in agreement with a laboratory critical care blood analyzer.
引用
收藏
页码:1315 / 1318
页数:4
相关论文
共 50 条
  • [41] Point-of-care measurement of fetal blood lactate - Time to trust a new device
    Wang, Mandy
    Chua, Seng C.
    Bouhadir, Lilain
    Treadwell, Erin L.
    Gibbs, Emma
    McGee, Therese M.
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2018, 58 (01): : 72 - 78
  • [42] Comparison of point-of-care and central laboratory analyzers for blood gas and lactate measurements
    Indrasari, Nuri Dyah
    Wonohutomo, Jessica Purwanti
    Sukartini, Ninik
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2019, 33 (05)
  • [43] Plasma lactate concentrations and comparison of two point-of-care lactate analyzers to a laboratory analyzer in a population of healthy cats
    Tynan, Beth
    Kerl, Marie E.
    Jackson, Mary L.
    Mann, F. A.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2015, 25 (04) : 521 - 527
  • [44] Evaluation of a rapid oral fluid point-of-care test for MDMA
    Wilson, Lisa
    Jehanli, Ahmed
    Hand, Chris
    Cooper, Gail
    Smith, Robert
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2007, 31 (02) : 98 - 104
  • [45] Point-of-care detection of lactate in cerebrospinal fluid
    Stephani, C.
    Choi, A. H. K.
    Moerer, O.
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2021, 9 (01)
  • [46] Point-of-care detection of lactate in cerebrospinal fluid
    C. Stephani
    A. H. K. Choi
    O. Moerer
    Intensive Care Medicine Experimental, 9
  • [47] FEASIBILITY STUDY OF A POINT-OF-CARE ASSAY FOR RAPID DETERMINATION OF ANTI-TNFA BIOLOGICS IN CAPILLARY BLOOD
    Reinhard, Christian
    Ricken, Benjamin
    Brosi, Larissa
    Anchling, Leslie
    Neu, Stefan
    Afonso, Joana
    Schuster, Thomas
    Wuthrich, Elina
    Burri, Emanuel
    Paul, Stephane
    Berger, Anne
    Guirao, Wanda
    Barrau, Mathilde
    Bastide, Leaetitia
    Roblin, Xavier
    Pflimlin-Fritschy, Veronique
    Ruscher, Uta
    Hruz, Petr
    Gerhold, Christian B.
    GASTROENTEROLOGY, 2024, 166 (05) : S1100 - S1100
  • [48] Feasibility study of a Point-of-Care assay for rapid determination of anti-TNFα biologics in capillary blood
    Ricken, B.
    Brosi, L.
    Reinhard, C.
    Anchling, L.
    Neu, S.
    Afonso, J.
    Schuster, T.
    Wutherich, E.
    Burri, E.
    Paul, S.
    Berger, A. E.
    Guirao, W.
    Barrau, M.
    Bastide, L.
    Roblin, X.
    Pflimlin-Fritschy, V.
    Rutscher, U.
    Hruz, P.
    Gerhold, C. B.
    JOURNAL OF CROHNS & COLITIS, 2024, 18 : I887 - I887
  • [49] The Triage® MPO test:: A rapid one-step point-of-care immunoassay for the determination of myeloperoxidase in blood
    Vijayendran, R.
    Jost, M.
    Mahal, J.
    McPherson, P.
    Dahlen, J.
    Blankenberg, S.
    Buechler, K.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A139 - A140
  • [50] Evaluation of a rapid test for point-of-care detection of cardiac troponin I in serum of healthy and diseased dogs and cats
    Santarelli, G.
    Marcos, P. Sebastian
    Talavera, J.
    Aznar-Cervantes, S. D.
    del Palacio, J. Fernandez
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2024, 34 (06) : 539 - 544