A comprehensive air quality investigation at an aquatic centre: Indoor/outdoor comparisons

被引:12
|
作者
Tolis, Evangelos I. [1 ,2 ]
Panaras, Giorgos [1 ]
Bartzis, John G. [1 ]
机构
[1] Univ Western Macedonia, Dept Mech Engn, Environm Technol Lab, Sialvera & Bakola St, Kozani 50100, Greece
[2] Univ Western Macedonia, Dept Environm Engn, Sialvera & Bakola St, Kozani 50100, Greece
关键词
Air quality; VOC; PM2.5; Aquatic centre; Diurnal variation; Ionic species; INDOOR SWIMMING-POOL; CHEMICAL-CHARACTERIZATION; PARTICULATE MATTER; BY-PRODUCTS; PM2.5; WATER; EXPOSURE; GREECE; THESSALONIKI; CHINA;
D O I
10.1007/s11356-018-1882-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Air quality and comfort parameters in a naturally ventilated aquatic centre were studied in relation to the outdoor pollution levels. Simultaneous measurements of PM 2.5, as well as of volatile organic compounds, were carried out for the indoor and outdoor environment of the aquatic centre. The chemical analysis of ionic species and trace elements associated with particulate matter was also performed. In addition, automated analyzer for NO2 and O-3 was used in order to record the indoor and outdoor levels of these pollutants. Analysis of diurnal variation of the pollutants' concentration was applied to the collected data, allowing the identification of potential variation on the sources affecting the indoor air quality. PM 2.5 concentration was almost two times higher indoors than outdoors with average values of 13.96 and 6.78 mu g/m(3), respectively. Concerning the ion fraction of PM 2.5, SO4 (2-) and Ca2+ were the ions with higher concentration indoors with values of 1.06 and 0.93 mu g/m(3), respectively, while the percentage of Cl- to the PM 2.5 fraction of the indoor atmosphere (9%) was too high than outdoor ones (1%). These results showed that indoor air of swimming pool concerning PM 2.5 and ionic species is mainly affected by the chlorination process along with the comfort conditions (high relative humidity) created during the operation of the facility. The common volatile organic compound concentrations at indoor air are generally in higher levels, compared to the outdoor air with p,m-xylene and toluene to be the substances with the higher concentration for indoor and outdoor area, respectively (7.80 and 1.57 mu g/m(3)); nevertheless, values were rather low compared with the findings of other studies. Also, they clearly demonstrate a diurnal variation as a result of poor ventilation during night. As it was expected, chloroform showed the highest concentration compared to the other volatile organic compounds with values ranging from 3.35 to 135.89 mu g/m(3), with an average of 54.50 mu g/m(3). Concerning the NO2 concentration, indoor levels showed an increased pattern when the swimming pool was fully occupied, a fact that reveals a possible correlation. As an overall conclusion, the natural ventilation and the disinfection process seem to play a key role to the air quality of the indoor air of the aquatic centre.
引用
收藏
页码:16710 / 16719
页数:10
相关论文
共 50 条
  • [21] Modeling relationships between indoor and outdoor air quality
    Freijer, JI
    Bloemen, HJT
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (02) : 292 - 300
  • [22] Special Issue: Indoor/Outdoor Airflow and Air Quality
    Yang, Xudong
    Zhao, Bin
    [J]. BUILDING SIMULATION, 2010, 3 (01) : 1 - 2
  • [23] Relationships between indoor and outdoor air quality in Delhi
    Srivastava, A
    Jain, VK
    [J]. INDOOR AND BUILT ENVIRONMENT, 2003, 12 (03) : 159 - 165
  • [24] EFFECTIVENESS OF INDOOR AIR QUALITY IMPROVEMENT WITH OUTDOOR AIR FOR BUILDING VENTILATION
    Wang, J.
    Zhang, X.
    Zhou, X.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 417 - 421
  • [25] Effects of Indoor Air Quality in Subway Systems according to Changes in Outdoor Air Quality
    Son, Youn-Suk
    Yu, Seong-ji
    Seo, Seo Hee
    Choi, In-young
    [J]. JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2022, 38 (01) : 13 - 29
  • [26] Fuzzy comprehensive evaluation on the quality of the indoor air
    Zhu, ZG
    Zhao, ST
    Ning, ZW
    Hu, B
    Huang, YD
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 498 - 502
  • [27] Indoor air quality investigation protocols
    Greene, RE
    Williams, PL
    [J]. JOURNAL OF ENVIRONMENTAL HEALTH, 1996, 59 (03) : 6 - &
  • [28] Investigation of indoor/outdoor air pollutants at the shopping malls in Wuhan
    Wen, Yuangao
    Lian, Zhiwei
    Lan, Li
    Ye, Xiaojiang
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2011, 45 (1-3) : 268 - 280
  • [29] THE EFFECTS OF INDOOR AND OUTDOOR AIR QUALITY ON RESPIRATORY PARAMETERS IN CANAKKALE
    Mirici, Arzu
    Mentese, Sibel
    Bakar, Coskun
    Otkun, Muserref
    Cevizci, Sibel
    Turan, Onur
    [J]. RESPIROLOGY, 2015, 20 : 77 - 77
  • [30] Photocatalytic Lime Render for Indoor and Outdoor Air Quality Improvement
    Ibanez Gomez, Jose Antonio
    Giampiccolo, Andrea
    Tobaldi, David Maria
    Mair, Sabine
    da Silva, Carla Forbela
    Barrasa, Maria Casado
    Maskell, Daniel
    Ansell, Martin Philip
    Kurchania, Rajnish
    Mayer, Florian
    Labrincha, Joao Antonio
    de Miguel, Yolanda R.
    Ball, Richard James
    [J]. CATALYSTS, 2021, 11 (03) : 1 - 21