Photocatalytic Lime Render for Indoor and Outdoor Air Quality Improvement

被引:1
|
作者
Ibanez Gomez, Jose Antonio [1 ]
Giampiccolo, Andrea [2 ]
Tobaldi, David Maria [3 ,4 ]
Mair, Sabine [5 ]
da Silva, Carla Forbela [2 ]
Barrasa, Maria Casado [6 ]
Maskell, Daniel [2 ]
Ansell, Martin Philip [2 ]
Kurchania, Rajnish [7 ]
Mayer, Florian [5 ]
Labrincha, Joao Antonio [3 ]
de Miguel, Yolanda R. [1 ]
Ball, Richard James [2 ]
机构
[1] TECNALIA, Basque Res & Technol Alliance BRTA, Parque Tecnol Bizkaia,Edificio 700, Derio 48160, Spain
[2] Univ Bath, BRE Ctr Innovat Construct Mat, Dept Architecture & Civil Engn, Bath BA2 7AY, Avon, England
[3] Univ Aveiro, Dept Mat & Ceram Engn, CICECO Aveiro Inst Mat, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[4] CNR Nanotec, Inst Nanotechnol, Campus Ecoteckne, I-73100 Lecce, Italy
[5] Fraunhofer Inst Bldg Phys, Holzkirchen Branch, Fraunhoferstr 10, D-83626 Valley, Germany
[6] ACCIONA Construcc Technol & Innovat Ctr, C Valportillo II,8, Alcobendas 28108, Spain
[7] Maulana Azad Natl Inst Technol MANIT, Dept Phys, Funct Nanomat Lab, Bhopal 462003, India
关键词
photocatalytic; TiO2; nanoparticles; UV and visible light; lime render; air purification; NOx; formaldehyde; TIO2; PHOTOCATALYSIS; TITANIUM-DIOXIDE; PARTICLE-SIZE; MORTARS; NANOPARTICLES; DEGRADATION; PURIFICATION; TECHNOLOGIES; FORMALDEHYDE; CARBONATION;
D O I
10.3390/catal11030296
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This article reports a novel photocatalytic lime render for indoor and outdoor air quality improvement that is composed of a lime binder and doped TiO2 (KRONOClean 7000(R)) nanoparticles. These nanoparticles were distributed throughout the bulk of the finishing render, instead of as a thin coating, thus ensuring the durability of the photocatalytic properties upon superficial damage. The physical properties of these renders were not affected by the addition of nanoparticles except in the case of surface area, which increased significantly. In terms of their photocatalytic activity, these novel lime renders were shown to degrade up to 12% NOx under UV light and up to 11% formaldehyde under visible light.
引用
收藏
页码:1 / 21
页数:21
相关论文
共 50 条
  • [1] EFFECTIVENESS OF INDOOR AIR QUALITY IMPROVEMENT WITH OUTDOOR AIR FOR BUILDING VENTILATION
    Wang, J.
    Zhang, X.
    Zhou, X.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 417 - 421
  • [2] INDOOR/OUTDOOR AIR QUALITY RELATIONSHIPS
    YOCOM, JE
    CLINK, WL
    COTE, WA
    [J]. JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1971, 21 (05): : 251 - &
  • [3] COMPARATIVE INDOOR AND OUTDOOR AIR QUALITY
    YOCOM, JE
    [J]. ASHRAE JOURNAL, 1970, 12 (01): : 53 - &
  • [4] COMPARISON OF INDOOR AND OUTDOOR AIR QUALITY.
    Moschandreas, D.J.
    Zabransky, J.
    Pelton, D.J.
    [J]. Electric Power Research Institute (Report) EPRI EA, 1981,
  • [5] Indoor and outdoor air contaminants coupling relationship and measures of improving indoor air quality
    Geng, Shibin
    Xiao, Mingxing
    [J]. SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 711 - 717
  • [6] Characterization of indoor air quality using an indoor/outdoor microenvironmental model
    Glytsos, T.
    Smolvk, J.
    Lazaridis, M.
    [J]. RECENT PROGRESS IN COMPUTATIONAL SCIENCES AND ENGINEERING, VOLS 7A AND 7B, 2006, 7A-B : 678 - +
  • [7] Wildfire Impact on Indoor and Outdoor PAH Air Quality
    Ghetu, Christine C.
    Rohlman, Diana
    Smith, Brian W.
    Scott, Richard P.
    Adams, Kaley A.
    Hoffman, Peter D.
    Anderson, Kim A.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2022, 56 (14) : 10042 - 10052
  • [8] Air quality assessment in indoor and outdoor environments: A review
    Prabhakaran, J.
    Jayabal, S.
    Kumar, A. Ramesh
    Vinoth, V.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 1260 - 1266
  • [9] Indoor and outdoor air quality investigation at universities in Wuhan
    Ye, Xiaojiang
    Chen, Huanxin
    Zhou, Zhaoxia
    Lian, Zhiwei
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 470 - 475
  • [10] Modeling relationships between indoor and outdoor air quality
    Freijer, JI
    Bloemen, HJT
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (02) : 292 - 300