Rapid and sensitive determination of enzyme kinetics of drug metabolism using HPLC coupled with a stop-flow radioactivity flow detector

被引:0
|
作者
Zhao, WP [1 ]
Wang, LF [1 ]
Zhang, DL [1 ]
Zhu, MS [1 ]
机构
[1] Bristol Myers Squibb Co, PCO, Biotransformat, Princeton, NJ 08543 USA
关键词
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
514
引用
收藏
页码:257 / 257
页数:1
相关论文
共 47 条
  • [41] Specific determination of myo-inositol in multivitamin pharmaceutical preparations by a flow injection system using a myo-inositol dehydrogenase reactor coupled with a glucose eliminating enzyme reactor
    Ono, M
    Nakajima, T
    Itoh, Y
    Shimada, K
    Yamato, S
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) : 1175 - 1180
  • [42] Simultaneous determination of oxacillin and cloxacillin in plasma and CSF using turbulent flow liquid chromatography coupled to high-resolution mass spectrometry: Application in therapeutic drug monitoring
    Mahfoudhi, Sarra
    Mory, Celine
    Le Ven, Jessica
    Coudore, Francois
    El Helali, Najoua
    Safta, Fethi
    Le Monnier, Alban
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1233
  • [43] RAPID, SENSITIVE FLUORIMETRIC ASSAY FOR PROTEASES USING FLUORESCEIN-LABELED ALBUMIN COUPLED TO FRACTOGEL ACTIVATED WITH 2-FLUORO-1-METHYLPYRIDINIUM SALT IN FLOW-INJECTION ANALYSIS
    NARINESINGH, D
    POPE, A
    NGO, TT
    ANALYTICA CHIMICA ACTA, 1990, 230 (01) : 131 - 136
  • [44] CONTINUOUS-FLOW DETERMINATION OF LOW CONCENTRATIONS OF UREA IN NATURAL-WATERS USING AN IMMOBILIZED UREASE ENZYME REACTOR AND AN AMMONIA GAS-SENSING MEMBRANE-ELECTRODE DETECTOR SYSTEM
    HARA, H
    KITAGAWA, T
    OKABE, Y
    ANALYST, 1993, 118 (10) : 1317 - 1320
  • [45] Polyaniline/graphene quantum dot-modified screen-printed carbon electrode for the rapid determination of Cr(VI) using stopped-flow analysis coupled with voltammetric technique
    Punrat, Eakkasit
    Maksuk, Chakkarin
    Chuanuwatanakul, Suchada
    Wonsawat, Wanida
    Chailapakul, Orawon
    TALANTA, 2016, 150 : 198 - 205
  • [46] Uricase-adsorbed carbon-felt reactor coupled with a peroxidase-modified carbon-felt-based H2O2 detector for highly sensitive amperometric flow determination of uric acid
    Wang, Yue
    Hasebe, Yasushi
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 57 : 125 - 132
  • [47] A simple and rapid microwave-assisted extraction method using polypropylene tubes for the determination of total mercury in environmental samples by flow injection chemical vapour generation inductively coupled plasma mass spectrometry (FI-CVG-ICP-MS)
    Krishna, M. V. Balarama
    Chandrasekaran, K.
    Karunasagar, D.
    ANALYTICAL METHODS, 2012, 4 (05) : 1401 - 1409