Automatic implantable cardioverter defibrillator for the treatment of ventricular fibrillation following coronary artery spasm - A case report

被引:9
|
作者
Al-Sayegh, Ali [1 ]
Shukkur, Abdul Mohammed [1 ]
Akbar, Moussa [1 ]
机构
[1] Chest Dis Hosp, Div Cardiol, Rawda, Kuwait
关键词
D O I
10.1177/0003319706295510
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Coronary artery spasm is an infrequently recognized condition that causes Prinzmetal's angina and specific electrocardiographic changes. A 50-year-old man who suffered a spontaneously aborted acute inferior myocardial infarction is presented. He underwent cardiac catheterization, which initially showed a normal coronary artery. The coronary angiogram was repeated shortly after a second presentation of acute coronary syndrome and ventricular fibrillation. Coronary spasm of very proximal right coronary artery was present, which was reversed completely with intracoronary nitroglycerin. The spasm segment was first stented. Subsequently, an automatic implantable cardioverter defibrillator was inserted because of the uncertainty of future spasm recurrence. The patient was discharged with oral isosorbide dinitrate. and Amlodipine. In further follow-up, the patient had two separate shocks within 4 months of implantation. Ventricular fibrillation was the trigger for the shock therapy in both occasions.
引用
收藏
页码:122 / 125
页数:4
相关论文
共 50 条
  • [41] REDO MIDSTERNOTOMY FOR CORONARY-ARTERY BYPASS-GRAFTING AFTER A PREVIOUS PLACEMENT OF AN AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - A CASE-REPORT
    EISEN, MM
    OLEARCHYK, AS
    VASCULAR SURGERY, 1993, 27 (07): : 539 - 541
  • [42] THE CLINICAL IMPORTANCE OF IMPLANTABLE CARDIOVERTER DEFIBRILLATOR FOR VENTRICULAR FIBRILLATION DUE TO VASOSPASTIC ANGINA: REPORT OF 7 CASES
    Sugiyama, K.
    Inaba, O.
    Nakamura, T.
    Yagishita, A.
    Tanaka, Y.
    Sasano, T.
    Kawabata, M.
    Hachiya, H.
    Hirao, K.
    Okishige, K.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S156 - S156
  • [43] Heart rate variability before ventricular arrhythmias in patients with coronary artery disease and an implantable cardioverter defibrillator
    Copie, X
    Lamaison, D
    Salvador, M
    Sadoul, N
    Da Costa, A
    Fauchier, L
    Legal, F
    Le Heuzey, JY
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2003, 8 (03) : 179 - 184
  • [44] Failure to detect ventricular fibrillation in a patient with an implantable cardioverter-defibrillator [3]
    Antolinos-Pérez, María J.
    García-Alberola, Arcadio
    Redondo-Bermejo, Belén
    Valdés-Chávarri, Mariano
    Technische Uberwachung, 2006, 47 (06): : 517 - 518
  • [45] The implantable cardioverter defibrillator prolongs survival in ventricular fibrillation patients who are revascularized
    Link, MS
    Cesarz, CA
    Costeas, XF
    Estes, NAM
    Wang, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 37126 - 37126
  • [46] Reproducibility of ventricular fibrillation characteristics in patients undergoing implantable cardioverter defibrillator implantation
    Taneja, T
    Goldberger, J
    Parker, MA
    Johnson, D
    Robinson, N
    Horvath, G
    Kadish, AH
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (11) : 1209 - 1217
  • [47] SHOCK DELIVERED BY AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN RESPONSE TO SPONTANEOUS VENTRICULAR FIBRILLATION
    ROELKE, M
    ONUNAIN, SS
    NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (13): : 860 - 860
  • [48] Ventricular fibrillation effectively treated by wearable automatic defibrillator - a case report
    Budzikowski, Adam S.
    Mitre, Cristina A.
    Bustros, Thomas
    Esan, Opesanmi
    Kassotis, John T.
    KARDIOLOGIA POLSKA, 2011, 69 (01) : 89 - 90
  • [49] Pacing-dependency following implantable cardioverter-defibrillator shocks: A case report
    Webber, Matthew R.
    Levings, Sacha L.
    Stiles, Martin K.
    JOURNAL OF ELECTROCARDIOLOGY, 2013, 46 (02) : 142 - 144
  • [50] Renal Artery Thrombosis Following an Inappropriate Implantable Cardioverter Defibrillator Shock
    Arias, Miguel A.
    De La Rosa, Cristina
    Puchol, Alberto
    Rodriguez-Padial, Luis
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (09): : e263 - e264