False malalignment after computer-navigated total knee arthroplasty

被引:2
|
作者
Tsukeoka, Tadashi [1 ]
Tsuneizumi, Yoshikazu [1 ]
机构
[1] Chiba Rehabil Ctr, Dept Orthopaed Surg, Chiba, Japan
来源
KNEE | 2021年 / 30卷
关键词
Total knee arthroplasty; Computer navigation; Malignment; Two-dimensional (2D) measurement; Three-dimensional (3D) measurement; CORONAL ALIGNMENT; VARUS; POSITION; ROTATION; FLEXION; LIMB;
D O I
10.1016/j.knee.2021.03.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although computer navigation has improved component alignment in total knee arthroplasty (TKA), radiographic outliers are reported with a wide range in literature even using this technique. We hypothesized that the postoperative malalignment after computer-navigated TKA was partially derived from the inherent problems with twodimensional (2D) measurement such as inaccuracies in measurement due to the knee position during the radiographic examination and the direction of the X-ray beam. We therefore conducted this study to determine how often knees with malalignment on 2D imaging were truly mal-aligned on three-dimensional (3D) reconstructed imaging. Methods: Sixty-two computer-navigated primary TKAs performed in 47 patients were included in this study. In all cases, a weight-bearing long-leg radiograph was obtained after TKA. 3D measurements were performed for outliers 2 degrees or more in coronal alignment of the femoral or tibial component. Results: For the 18 femoral mal-aligned components on 2D imaging, eight (44.4%) were not truly mal-aligned on 3D imaging (P = 0.0014). For the eight tibial mal-aligned components on 2D imaging, all knees (100%) were not truly mal-aligned on 3D imaging (P < 0.0001). Conclusions: A considerable number of the false malalignments were included on 2D measurement. Postoperative component alignment in the computer-navigated TKA might be much better than previously reported. (c) 2021 Elsevier B.V. All rights reserved. Computer-navigated total knee arthroplasty (TKA) was introduced with the intention of improving implant alignment with the hope that this would lead to improvement in clinical outcomes and implant survival [1-3]. However, despite having no outliers intra-operatively during computer-navigated TKA, radiographic outliers in coronal alignment are reported with a wide range in the literature [4]. In most cases, alignment after TKA was assessed using two-dimensional (2D) measurements with long-leg standing X
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [41] Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature
    Reininga, Inge H. F.
    Zijlstra, Wiebren
    Wagenmakers, Robert
    Boerboom, Alexander L.
    Huijbers, Bregtje P.
    Groothoff, Johan W.
    Bulstra, Sjoerd K.
    Stevens, Martin
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [42] Joint line changes in cruciate-retaining versus posterior-stabilized computer-navigated total knee arthroplasty
    Bin Abd Razak, Hamid Rahmatullah
    Pang, Hee Nee
    Yeo, Seng Jin
    Tan, Mann Hong
    Lo, Ngai Nung
    Chong, Hwei Chi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (06) : 853 - 859
  • [43] Clinical outcomes associated with robotic and computer-navigated total knee arthroplasty: a machine learning-augmented systematic review
    Quinlan D. Buchlak
    Joe Clair
    Nazanin Esmaili
    Arshad Barmare
    Siva Chandrasekaran
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 915 - 931
  • [44] Clinical outcomes associated with robotic and computer-navigated total knee arthroplasty: a machine learning-augmented systematic review
    Buchlak, Quinlan D.
    Clair, Joe
    Esmaili, Nazanin
    Barmare, Arshad
    Chandrasekaran, Siva
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (05): : 915 - 931
  • [45] Location and number of cortical fixation points and the effect on reference base stability during computer-navigated total knee arthroplasty
    Mihalko, William M.
    Duquin, Thomas
    Axelrod, Jed R.
    Fisher, Landis
    JOURNAL OF ARTHROPLASTY, 2007, 22 (04): : 605 - 608
  • [46] Joint line changes in cruciate-retaining versus posterior-stabilized computer-navigated total knee arthroplasty
    Hamid Rahmatullah Bin Abd Razak
    Hee Nee Pang
    Seng Jin Yeo
    Mann Hong Tan
    Ngai Nung Lo
    Hwei Chi Chong
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 853 - 859
  • [47] Postoperative outcomes and trends in computer-navigated and robotic-assisted total hip arthroplasty
    Piple, Amit S.
    Wang, Jennifer C.
    Hill, William
    Chen, Matthew S.
    Gettleman, Brandon S.
    Liu, Kevin C.
    Heckmann, Nathanael D.
    Christ, Alexander B.
    HIP INTERNATIONAL, 2024, 34 (05) : 569 - 577
  • [48] Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature
    Inge HF Reininga
    Wiebren Zijlstra
    Robert Wagenmakers
    Alexander L Boerboom
    Bregtje P Huijbers
    Johan W Groothoff
    Sjoerd K Bulstra
    Martin Stevens
    BMC Musculoskeletal Disorders, 11
  • [49] Training benefits of-computer navigated total knee arthroplasty
    Love, Gavin J.
    Kinninmonth, Andrew W. G.
    KNEE, 2013, 20 (04): : 236 - 241
  • [50] Minimally invasive imageless computer-navigated knee surgery
    Chandrasekaran, Sivashankar
    Molnar, Robert B.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 441 - 445