False malalignment after computer-navigated total knee arthroplasty

被引:2
|
作者
Tsukeoka, Tadashi [1 ]
Tsuneizumi, Yoshikazu [1 ]
机构
[1] Chiba Rehabil Ctr, Dept Orthopaed Surg, Chiba, Japan
来源
KNEE | 2021年 / 30卷
关键词
Total knee arthroplasty; Computer navigation; Malignment; Two-dimensional (2D) measurement; Three-dimensional (3D) measurement; CORONAL ALIGNMENT; VARUS; POSITION; ROTATION; FLEXION; LIMB;
D O I
10.1016/j.knee.2021.03.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although computer navigation has improved component alignment in total knee arthroplasty (TKA), radiographic outliers are reported with a wide range in literature even using this technique. We hypothesized that the postoperative malalignment after computer-navigated TKA was partially derived from the inherent problems with twodimensional (2D) measurement such as inaccuracies in measurement due to the knee position during the radiographic examination and the direction of the X-ray beam. We therefore conducted this study to determine how often knees with malalignment on 2D imaging were truly mal-aligned on three-dimensional (3D) reconstructed imaging. Methods: Sixty-two computer-navigated primary TKAs performed in 47 patients were included in this study. In all cases, a weight-bearing long-leg radiograph was obtained after TKA. 3D measurements were performed for outliers 2 degrees or more in coronal alignment of the femoral or tibial component. Results: For the 18 femoral mal-aligned components on 2D imaging, eight (44.4%) were not truly mal-aligned on 3D imaging (P = 0.0014). For the eight tibial mal-aligned components on 2D imaging, all knees (100%) were not truly mal-aligned on 3D imaging (P < 0.0001). Conclusions: A considerable number of the false malalignments were included on 2D measurement. Postoperative component alignment in the computer-navigated TKA might be much better than previously reported. (c) 2021 Elsevier B.V. All rights reserved. Computer-navigated total knee arthroplasty (TKA) was introduced with the intention of improving implant alignment with the hope that this would lead to improvement in clinical outcomes and implant survival [1-3]. However, despite having no outliers intra-operatively during computer-navigated TKA, radiographic outliers in coronal alignment are reported with a wide range in the literature [4]. In most cases, alignment after TKA was assessed using two-dimensional (2D) measurements with long-leg standing X
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [21] Computer-navigated versus conventional total knee arthroplasty A randomized controlled trial protocol in China
    Yu, Yefeng
    Sheng, Jianming
    Zhou, Xiao
    MEDICINE, 2020, 99 (32) : E21508
  • [22] Principles and new concepts in computer-navigated total hip arthroplasty
    Renkawitz, T.
    Woerner, M.
    Sendtner, E.
    Weber, M.
    Lechler, P.
    Grifka, J.
    ORTHOPADE, 2011, 40 (12): : 1095 - +
  • [23] Handheld computer-navigated constrained total knee arthroplasty for complex extra-articular deformities
    M. Pietsch
    M. Hochegger
    O. Djahani
    G. Mlaker
    M. Eder-Halbedl
    Th. Hofstädter
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 2245 - 2254
  • [24] Handheld computer-navigated constrained total knee arthroplasty for complex extra-articular deformities
    Pietsch, M.
    Hochegger, M.
    Djahani, O.
    Mlaker, G.
    Eder-Halbedl, M.
    Hofstadter, Th
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2245 - 2254
  • [25] Low Incidence of Postoperative Complications Due to Pin Placement in Computer-Navigated Total Knee Arthroplasty
    Owens, Richard F., Jr.
    Swank, Michael L.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (07): : 1096 - 1098
  • [26] Experiences with computer navigated total knee arthroplasty
    Zoltán Bejek
    László Sólyom
    Miklós Szendrõi
    International Orthopaedics, 2007, 31 : 617 - 622
  • [27] Experiences with computer navigated total knee arthroplasty
    Bejek, Zoltan
    Solyom, Laszlo
    Szendroi, Miklos
    INTERNATIONAL ORTHOPAEDICS, 2007, 31 (05) : 617 - 622
  • [28] Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty
    Catani, Fabio
    Biasca, Nicola
    Ensini, Andrea
    Leardini, Alberto
    Bianchi, Luca
    Digennaro, Vitantonio
    Giannini, Sandro
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (04): : 765 - 771
  • [29] Computer-Navigated and Robotic-Assisted Total Knee Arthroplasty: Increasing in Popularity Without Increasing Complications
    Wang, Jennifer C.
    Piple, Amit S.
    Hill, William J.
    Chen, Matthew S.
    Gettleman, Brandon S.
    Richardson, Mary
    Heckmann, Nathanael D.
    Christ, Alexander B.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (12): : 2358 - 2364
  • [30] Averaging Different Alignment Axes Improves Femoral Rotational Alignment in Computer-Navigated Total Knee Arthroplasty
    Siston, Robert A.
    Cromie, Melinda J.
    Gold, Garry E.
    Goodman, Stuart B.
    Delp, Scott L.
    Maloney, William J.
    Giori, Nicholas J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (10): : 2098 - 2104