Hydrous Cerium Dioxide-Based Materials as Solid-Contact Layers in Potassium-Selective Electrodes

被引:9
|
作者
Lenar, Nikola [1 ]
Piech, Robert [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Mickiewicza 30, PL-30059 Krakow, Poland
关键词
hydrous cerium dioxide; potassium determination; potentiometric sensing; hydrophobic materials; high electrical capacity; solid contact ion-selective electrodes; CAPACITANCE;
D O I
10.3390/membranes12040349
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This paper introduces hydrous cerium dioxide applied for the first time as a solid-contact layer in ion-selective electrodes. Cerium dioxide belongs to the group of metal oxides that exhibit both redox activity and a large surface area and therefore was considered to be an appropriate material for the solid-contact layer in potentiometric sensors. The material was examined both standalone and as a component of composite materials (with the addition of carbon nanomaterial or conducting polymer). Three cerium dioxide-based materials were tested as solid-contact layers in potentiometric sensors in the context of their microstructure, wettability, and electrical properties. The addition of hydrous cerium dioxide was shown to enhance the properties of carbon nanotubes and poly(3-octylthiophene-2,5-diyl) by increasing the value of electrical capacitance (798 mu F and 112 mu F for hCeO(2)-NTs and hCeO(2)-POT material, respectively) and the value of contact angle (100 degrees and 120 degrees for hCeO(2)-NTs and hCeO(2)-POT material, respectively). The proposed sensor preparation method is easy, without the need to use an advanced apparatus or specific conditions, and fast; sensors can be prepared within an hour. Designed hCeO(2)-based electrodes exhibit competitive linear range and potential stability within the wide range of pH values (2.0-11.5). Designed electrodes are dedicated to potassium determination in environmental and clinical samples.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Potassium-selective electrodes with stable and geometrically well-defined internal solid contact based on nanoparticles of polyaniline and plasticized poly(vinyl chloride)
    Lindfors, Tom
    Aarnio, Harri
    Ivaska, Ari
    ANALYTICAL CHEMISTRY, 2007, 79 (22) : 8571 - 8577
  • [42] Recent advances in solid-contact ion-selective electrodes: functional materials, transduction mechanisms, and development trends
    Shao, Yuzhou
    Ying, Yibin
    Ping, Jianfeng
    CHEMICAL SOCIETY REVIEWS, 2020, 49 (13) : 4405 - 4465
  • [43] Solid-Contact Ion-Selective Electrodes with Copper Hexacyanoferrate in the Transducer Layer
    Timofeev, V. V.
    Levin, M. B.
    Starikova, A. A.
    Trofimov, M. A.
    Korneev, S. M.
    Mikhelson, K. N.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2018, 54 (04) : 400 - 408
  • [44] SOLID-CONTACT AMMONIUM-SELECTIVE MEMBRANE ELECTRODES FUNCTIONING IN MIXED-SOLUTIONS CONTAINING POTASSIUM-IONS
    ROZHDESTVENSKAYA, NV
    LUZANENKO, IR
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 1995, 67 (08) : 1213 - 1214
  • [45] Solid-Contact Ion-Selective Electrodes with Copper Hexacyanoferrate in the Transducer Layer
    V. V. Timofeev
    M. B. Levin
    A. A. Starikova
    M. A. Trofimov
    S. M. Korneev
    K. N. Mikhelson
    Russian Journal of Electrochemistry, 2018, 54 : 400 - 408
  • [46] Single-Piece Solid-Contact Pb2+-Selective Electrodes Based on Thiophene Oligomer
    Xu, Shuhua
    Yuan, Qun
    Yu, Shunyang
    Wu, Xuran
    ELECTROANALYSIS, 2012, 24 (10) : 2021 - 2025
  • [47] Microcavity based solid-contact ion-selective microelectrodes
    Sundfors, Fredrik
    Bereczki, Robert
    Bobacka, Johan
    Toth, Klara
    Ivaska, Ari
    Gyurcsanyi, Robert E.
    ELECTROANALYSIS, 2006, 18 (13-14) : 1372 - 1378
  • [48] Electrochemical properties and analytical advantages of potassium-selective sensor with tungsten trioxide solid contact
    Egrzyn, Katarzyna W.
    Michalska, Agata
    Maksymiuk, Krzysztof
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2023, 928
  • [49] Intercalation Compounds as Inner Reference Electrodes for Reproducible and Robust Solid-Contact Ion-Selective Electrodes
    Ishige, Yu
    Klink, Stefan
    Schuhmann, Wolfgang
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2016, 55 (15) : 4831 - 4835
  • [50] A ladder conjugated polymer transducer for solid-contact Cu2+-selective electrodes
    Shun-Yang Yu
    Yan-Cang Li
    Tao Xiong
    Qun Yuan
    Yong-Ming Liu
    Zhong-Yi Yuan
    Yi Xiao
    ChineseChemicalLetters, 2014, 25 (02) : 364 - 366