Hydrous Cerium Dioxide-Based Materials as Solid-Contact Layers in Potassium-Selective Electrodes

被引:9
|
作者
Lenar, Nikola [1 ]
Piech, Robert [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Mickiewicza 30, PL-30059 Krakow, Poland
关键词
hydrous cerium dioxide; potassium determination; potentiometric sensing; hydrophobic materials; high electrical capacity; solid contact ion-selective electrodes; CAPACITANCE;
D O I
10.3390/membranes12040349
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This paper introduces hydrous cerium dioxide applied for the first time as a solid-contact layer in ion-selective electrodes. Cerium dioxide belongs to the group of metal oxides that exhibit both redox activity and a large surface area and therefore was considered to be an appropriate material for the solid-contact layer in potentiometric sensors. The material was examined both standalone and as a component of composite materials (with the addition of carbon nanomaterial or conducting polymer). Three cerium dioxide-based materials were tested as solid-contact layers in potentiometric sensors in the context of their microstructure, wettability, and electrical properties. The addition of hydrous cerium dioxide was shown to enhance the properties of carbon nanotubes and poly(3-octylthiophene-2,5-diyl) by increasing the value of electrical capacitance (798 mu F and 112 mu F for hCeO(2)-NTs and hCeO(2)-POT material, respectively) and the value of contact angle (100 degrees and 120 degrees for hCeO(2)-NTs and hCeO(2)-POT material, respectively). The proposed sensor preparation method is easy, without the need to use an advanced apparatus or specific conditions, and fast; sensors can be prepared within an hour. Designed hCeO(2)-based electrodes exhibit competitive linear range and potential stability within the wide range of pH values (2.0-11.5). Designed electrodes are dedicated to potassium determination in environmental and clinical samples.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Potassium-selective membrane electrodes based on macrocyclic metacyclophanes analogous to calixarenes
    Katsu, T
    Yokoyama, Y
    Ueda, K
    Kohno, K
    Yamato, T
    ANALYTICAL SCIENCES, 2005, 21 (02) : 175 - 178
  • [32] Solid-contact polymer sensors based on composite materials
    Legin, AV
    Makarychev-Mikhailov, SM
    Kirsanov, DO
    Vlasov, YG
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2002, 75 (06) : 926 - 930
  • [33] Potassium-Selective Membrane Electrodes Based on Macrocyclic Metacyclophanes Analogous to Calixarenes
    Takashi Katsu
    Yuutaku Yokoyama
    Keisuke Ueda
    Kazufumi Kohno
    Takehiko Yamato
    Analytical Sciences, 2005, 21 : 175 - 178
  • [34] Ruthenium dioxide nanoparticles as a high-capacity transducer in solid-contact polymer membrane-based pH-selective electrodes
    Nikola Lenar
    Beata Paczosa-Bator
    Robert Piech
    Microchimica Acta, 2019, 186
  • [35] Ruthenium dioxide nanoparticles as a high-capacity transducer in solid-contact polymer membrane-based pH-selective electrodes
    Lenar, Nikola
    Paczosa-Bator, Beata
    Piech, Robert
    MICROCHIMICA ACTA, 2019, 186 (12)
  • [36] POTASSIUM-SELECTIVE ELECTRODES WITH POLYMER MEMBRANES BASED ON BIS(BENZOCROWN ETHERS)
    NAZAROVA, NY
    KHOLDT, KY
    AURIKH, Y
    KUNTOSH, G
    LUKYANENKO, NG
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1990, 45 (01): : 65 - 68
  • [37] SOLID CONTACT ELECTRODES, SELECTIVE TO POTASSIUM AND NITRATE IONS
    LEIS, LHJ
    ALAGOVA, ZS
    STEFANOVA, OK
    KARASIOVA, NN
    VESTNIK LENINGRADSKOGO UNIVERSITETA SERIYA FIZIKA KHIMIYA, 1986, (02): : 101 - 103
  • [38] Transduction Mechanism of Carbon Nanotubes in Solid-Contact Ion-Selective Electrodes
    Crespo, Gaston A.
    Macho, Santiago
    Bobacka, Johan
    Rius, F. Xavier
    ANALYTICAL CHEMISTRY, 2009, 81 (02) : 676 - 681
  • [39] New Signal Readout Principle for Solid-Contact Ion-Selective Electrodes
    Vanamo, Ulriika
    Hupa, Elisa
    Yrjana, Ville
    Bobacka, Johan
    ANALYTICAL CHEMISTRY, 2016, 88 (08) : 4369 - 4374
  • [40] Solid-contact ion-selective electrodes for potentiometric determination of phenylethylamine in vitro
    Ma, Siyuan
    Wang, You
    Jiang, Lizi
    Hu, Ruifen
    Luo, Zhiyuan
    Li, Guang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (11)