Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs

被引:5
|
作者
Petrus, Lilian C.
Oliveira, Valeria M. C. [1 ]
Pereira, Guilherme G. [1 ]
Larsson, Maria Helena M. A. [1 ]
机构
[1] Univ Sao Paulo, Dept Clin Med, Fac Med Vet & Zootecnia, BR-05508270 Sao Paulo, Brazil
来源
PESQUISA VETERINARIA BRASILEIRA | 2010年 / 30卷 / 07期
关键词
Doppler echocardiography; pulsed-wave Doppler; healthy dogs; BLOOD-FLOW; VELOCITY; HYPERTENSION; PRESSURE; PATTERNS; ARTERY;
D O I
10.1590/S0100-736X2010000700013
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliacao dos fluxos das valvas aortica e pulmonar com ecocardiografia Doppler pulsatil em caes clinicamente sadios. Pesquisa Veterinaria Brasileira 30(7):586-592. Departamento de Clinica Medica, Faculdade de Medicina Veterinaria e Zootecnia, Universidade de Sao Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, Sao Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com This study evaluated aortic (AO) and pulmonary (Pul) valves flow with pulsed-wave Doppler by qualitative (presence of valvar insufficiency and characteristic of flow profile) and quantitative analysis, and the following echocardiographic parameters were obtained: peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time. Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, thoracic radiography, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained: AO PV= 1.22 +/- 19.38m/s; AO MV= 0.72 +/- 0.08m/s; AO VTI= 0.14 +/- 0.02m; AO AT= 38.80 +/- 11.29ms; AO ET= 197.90 +/- 24.77ms; Pul PV= 0.95 +/- 0.18m/s; Pul MV= 0.63 +/- 0.10m/s; Pul VTI= 0.13 +/- 0.02m; Pul AT= 70.97 +/- 18.87ms; Pul ET= 203.70 +/- 28.98ms. Heart rate presented negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, Pul VTI, Pul ET, differently from the gender, that had no influence on the evaluated parameters. The comparison of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT.
引用
收藏
页码:586 / 592
页数:7
相关论文
共 50 条
  • [31] Use of pulsed-wave Doppler echocardiography to measure changes in MPAP - Is further validation required?
    Lipworth, BJ
    Kiely, D
    CHEST, 1997, 111 (05) : 1470 - 1470
  • [32] Cardiac output during total hip replacement in dogs;: comparison of trans-oesophageal pulsed-wave Doppler echocardiography and thermodilution
    Gantke, S
    Matis, U
    Böttcher, P
    Erhardt, W
    TIERARZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2000, 28 (03): : 178 - 188
  • [33] ECHOCARDIOGRAPHY OF AORTIC AND PULMONARY VALVES
    SHAH, PM
    SYLVESTER, LJ
    PROGRESS IN CARDIOVASCULAR DISEASES, 1978, 20 (06) : 451 - 462
  • [34] PULSED-WAVE DOPPLER EVALUATION OF INTRACARDIAC BLOOD-FLOW IN 30 CLINICALLY NORMAL STANDARDBRED HORSES
    REEF, VB
    LALEZARI, K
    DEBOO, J
    VANDERBELT, AJ
    SPENCER, PA
    DIK, KJ
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1989, 50 (01) : 75 - 83
  • [35] EVALUATION OF PULSED DOPPLER ECHOCARDIOGRAPHY FOR MEASUREMENT OF AORTIC BLOOD-FLOW IN THE FETAL LAMB
    VEILLE, JC
    TAVILL, M
    SIVAKOFF, M
    COHEN, I
    BENAMI, M
    YANG, YC
    JOVKOVSKY, V
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1989, 161 (06) : 1610 - 1614
  • [36] ASSESSMENT OF PULMONARY REGURGITATION BY CONTINUOUS WAVE AND PULSED DOPPLER ECHOCARDIOGRAPHY
    VITARELLI, A
    SCAPATO, A
    CARDAMONE, S
    CAMINITI, MC
    CLINICAL RESEARCH, 1986, 34 (02): : A352 - A352
  • [37] Evolution of echocardiography in adult congenital heart disease: from pulsed-wave Doppler to fusion imaging
    Norihisa Toh
    Teiji Akagi
    Shingo Kasahara
    Hiroshi Ito
    Journal of Echocardiography, 2021, 19 : 205 - 211
  • [38] Characterization of blood flow turbulence with pulsed-wave and power Doppler ultrasound imaging
    Cloutier, G
    Allard, L
    Durand, LG
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 318 - 325
  • [39] Association of age and heart rate with pulsed-wave doppler measurements in healthy, nonsedated cats
    Disatian, S.
    Bright, J. M.
    Boon, J.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2008, 22 (02): : 351 - 356
  • [40] Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography
    Galiuto, L
    Ignone, G
    DeMaria, AN
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (05): : 609 - 614