Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs

被引:5
|
作者
Petrus, Lilian C.
Oliveira, Valeria M. C. [1 ]
Pereira, Guilherme G. [1 ]
Larsson, Maria Helena M. A. [1 ]
机构
[1] Univ Sao Paulo, Dept Clin Med, Fac Med Vet & Zootecnia, BR-05508270 Sao Paulo, Brazil
来源
PESQUISA VETERINARIA BRASILEIRA | 2010年 / 30卷 / 07期
关键词
Doppler echocardiography; pulsed-wave Doppler; healthy dogs; BLOOD-FLOW; VELOCITY; HYPERTENSION; PRESSURE; PATTERNS; ARTERY;
D O I
10.1590/S0100-736X2010000700013
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliacao dos fluxos das valvas aortica e pulmonar com ecocardiografia Doppler pulsatil em caes clinicamente sadios. Pesquisa Veterinaria Brasileira 30(7):586-592. Departamento de Clinica Medica, Faculdade de Medicina Veterinaria e Zootecnia, Universidade de Sao Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, Sao Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com This study evaluated aortic (AO) and pulmonary (Pul) valves flow with pulsed-wave Doppler by qualitative (presence of valvar insufficiency and characteristic of flow profile) and quantitative analysis, and the following echocardiographic parameters were obtained: peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time. Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, thoracic radiography, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained: AO PV= 1.22 +/- 19.38m/s; AO MV= 0.72 +/- 0.08m/s; AO VTI= 0.14 +/- 0.02m; AO AT= 38.80 +/- 11.29ms; AO ET= 197.90 +/- 24.77ms; Pul PV= 0.95 +/- 0.18m/s; Pul MV= 0.63 +/- 0.10m/s; Pul VTI= 0.13 +/- 0.02m; Pul AT= 70.97 +/- 18.87ms; Pul ET= 203.70 +/- 28.98ms. Heart rate presented negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, Pul VTI, Pul ET, differently from the gender, that had no influence on the evaluated parameters. The comparison of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT.
引用
收藏
页码:586 / 592
页数:7
相关论文
共 50 条
  • [21] Pulsed-wave Doppler ultrasonographic evaluation of hepatic veins during variable of hepatic veins during hemodynamic states in healthy anesthetized dogs
    Smithenson, BT
    Mattoon, JS
    Bonagura, JD
    Abrahamsen, EJ
    Drost, WT
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2004, 65 (06) : 734 - 740
  • [22] Pulmonary venous flow characteristics as assessed by transthoracic pulsed Doppler echocardiography in normal dogs
    Schober, KE
    Fuentes, VL
    McEwan, JD
    French, AT
    VETERINARY RADIOLOGY & ULTRASOUND, 1998, 39 (01) : 33 - 41
  • [23] Ejaculation effect on blood testosterone and prostatic pulsed-wave Doppler ultrasound in dogs
    Alonge, Salvatore
    Melandri, Monica
    Leoci, Raffaella
    Lacalandra, Giovanni M.
    Aiudi, Giulio
    REPRODUCTION IN DOMESTIC ANIMALS, 2018, 53 : 70 - 73
  • [24] Left ventricular radial colour and longitudinal pulsed-wave tissue Doppler echocardiography in 39 healthy domestic pet rabbits
    Casamian-Sorrosal, Domingo
    Saunders, Richard
    Browne, William
    Elliot, Sarah
    Fonfara, Sonja
    RESEARCH IN VETERINARY SCIENCE, 2014, 97 (02) : 376 - 381
  • [25] Evaluation of right and left ventricular function using pulsed-wave tissue Doppler echocardiography in patients with subclinical hypothyroidism
    F. Kosar
    I. Sahin
    N. Turan
    E. Topal
    Y. Aksoy
    C. Taskapan
    Journal of Endocrinological Investigation, 2005, 28 : 704 - 710
  • [26] Evaluation of right and left ventricular function using pulsed-wave tissue Doppler echocardiography in patients with subclinical hypothyroidism
    Kosar, F
    Sahin, I
    Turan, N
    Topal, E
    Aksoy, Y
    Taskapan, C
    JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2005, 28 (08) : 704 - 710
  • [27] Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
    Hodges, Ryan
    Endo, Masayuki
    La Gerche, Andre
    Eixarch, Elisenda
    DeKoninck, Philip
    Ferferieva, Vessilina
    D'hooge, Jan
    Wallace, Euan M.
    Deprest, Jan
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (76):
  • [28] Tissue Doppler Combined with Pulsed-Wave Doppler Echocardiography for Evaluating Ventricular Diastolic Function in Normal Children
    Ichihashi, Ko
    Sato, Asami
    Shiraishi, Hirohiko
    Momoi, Mariko
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (01): : 93 - +
  • [29] PULSED DOPPLER ECHOCARDIOGRAPHY IN THE DIAGNOSIS AND EVALUATION OF AORTIC REGURGITATION
    BINIKOWSKI, Z
    KRZEMINSKAPAKULA, M
    ROGOWSKI, W
    DOBEK, J
    ACTA CARDIOLOGICA, 1988, 43 (03) : 197 - 201
  • [30] Novel approach to measure myocardial performance index:: Pulsed-wave tissue Doppler echocardiography
    Tekten, T
    Onbasili, AO
    Ceyhan, C
    Ünal, S
    Discigil, B
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2003, 20 (06): : 503 - 510