Transmittance Uncertainty Evaluation for a Broadband Spectrophotometer System

被引:0
|
作者
Chiu, Po-Kai [1 ]
Chiang, Donyau [1 ]
Cho, Wen-Hao [1 ]
Hsiao, Chien-Nan [1 ]
Lee, Chao-Te [1 ]
Chen, Fong Zhi [1 ]
机构
[1] Instrument Technol Res Ctr, Natl Appl Res Labs, Hsinchu 30076, Taiwan
关键词
uncertainty; transmittance; spectrophotometer; calibration;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The spectrophotometer is one of the instruments designed and manufactured by the advanced opto-mechanical technologies. To maintain its accuracy and preciseness, the instruments are required to be calibrated frequently. The transmittance measurement uncertainty of a spectrophotometer with considerations of the normal incidence of light beam and operator manipulation factors is performed. The calibration data and regular measured data can be transferred to the servo data center via internet for further data analysis, instrument healthy examination and predicted maintenance period. A double beam spectrophotometer is utilized, taking advantage of the direct comparison of the luminous intensity to evaluate the uncertainty. To measure the transmittance of a sample with a few tenths percent in calibration, the sample is required to be smooth surface, uniform and homogeneous composition, and environmental stability. The measured transmitted beam should be focused inside and no light will be scattered outside of the collecting integrating sphere. A series of transparent thin films, including absorb Ni film, high index TiO2 film and low index SiO2 film alternatively deposited carefully on the fused quartz substrates, are the calibration samples. Equations are given to calculate the transmittance for beam being normally incident on the substrate. Factors such as material aging and non-uniform optical thickness can introduce systematic errors into the calibration, and the errors must be minimized by proper choice of materials and preparation techniques. The environmental range of the temperature and the relative humidity during the measuring process are controlled as 23 +/- 1.5 oC and 50%+/- 10%, respectively. The calibrated transmittance ranges are within 10% - 100%. The optimal expanded combination uncertainties of the system are found to be 0.23247 (T1-1: above T30 %), 0.13265 (T1-2: T30%similar to 8%), 0.04728 (T1-3: T8%similar to 0.92%) and 0.02910 (T1-4: T0.92%similar to 0.107%) in the wavelength ranges of 400 nm - 700 nm.
引用
收藏
页码:1304 / 1307
页数:4
相关论文
共 50 条
  • [11] A spectrophotometer accessory for directional reflectance and transmittance of coated glazing
    Van Nijnatten, PA
    [J]. SOLAR ENERGY, 2002, 73 (03) : 137 - 149
  • [13] Determination of the total Ginsenosides in ginseng using the UV Spectrophotometer and Evaluation of the Measurement Uncertainty
    Zhang, Min
    Qin, Jane Yuxia
    Chen, Dan
    Yang, Ping
    [J]. MECHATRONICS AND INTELLIGENT MATERIALS II, PTS 1-6, 2012, 490-495 : 1290 - +
  • [14] INFRARED TRANSMITTANCE AT HIGH TEMPERATURE USING A DOUBLE BEAM SPECTROPHOTOMETER
    PARKER, CJ
    NORDBERG, ME
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1959, 49 (05) : 497 - 497
  • [15] Calibration of broadband UV radiometers - methodology and uncertainty evaluation
    Xu, G
    Huang, X
    [J]. METROLOGIA, 2003, 40 (01) : S21 - S24
  • [16] Short-medium infrared detection system broadband high transmittance film
    Fu, Xiuhua
    Zhang, Gong
    Zhang, Jing
    Liu, Dongmei
    Yang, Weisheng
    Mu, Rui
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2019, 48 (10):
  • [17] INFRARED TRANSMITTANCE AT HIGH TEMPERATURE USING A DOUBLE-BEAM SPECTROPHOTOMETER
    PARKER, CJ
    NORDBERG, ME
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1959, 49 (09) : 856 - 859
  • [18] Spectrophotometer for measuring spectral transmittance and reflectance of large aperture optical element
    Liu, J
    Li, HF
    Liu, X
    Gu, PF
    [J]. OPTICAL DESIGN AND TESTING II, PTS 1 AND 2, 2005, 5638 : 229 - 236
  • [19] FOURIER-TRANSFORM INFRARED SPECTROPHOTOMETER FOR TRANSMITTANCE AND DIFFUSE REFLECTANCE MEASUREMENTS
    WILLEY, RR
    [J]. APPLIED SPECTROSCOPY, 1976, 30 (06) : 593 - 601
  • [20] Clinical evaluation of a dental color analysis system: The Crystaleye Spectrophotometer®
    Odaira, Chikayuki
    Itoh, Sozo
    Ishibashi, Kanji
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2011, 55 (04) : 199 - 205