High-Frame Rate Vector Flow Imaging of the Carotid Bifurcation in Healthy Adults: Comparison With Color Doppler Imaging

被引:32
|
作者
Goddi, Alfredo [1 ]
Bortolotto, Chandra [2 ]
Raciti, Maria Vittoria [2 ]
Fiorina, Ilaria [2 ]
Aiani, Luca [1 ]
Magistretti, Giovanni [1 ]
Sacchi, Andrea [1 ]
Tinelli, Carmine [3 ]
Calliada, Fabrizio [2 ]
机构
[1] Ctr Med SME Diagnost Immagini, Varese, Italy
[2] Univ Pavia, Radiol Unit, Fdn Ist Ricovero & Cura Carattere Sci Policlin Sa, Viale Oberdan 21, I-27100 Pavia, Italy
[3] Fdn Ist Ricovero & Cura Carattere Sci Policlin Sa, Clin Epidemiol & Biometr Unit, Pavia, Italy
关键词
carotid arteries; Doppler imaging; hemodynamic; plane wave imaging; ultrasound; vascular (diagnostic); vector flow imaging; WALL SHEAR-STRESS; BLOOD-FLOW; VELOCITY ESTIMATION; TRANSIENT ELASTOGRAPHY; PLANE-WAVES; ULTRASOUND; ATHEROSCLEROSIS; VISUALIZATION; ATHEROGENESIS; PATTERNS;
D O I
10.1002/jum.14579
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
ObjectivesTo evaluate the carotid bifurcation in healthy adults using a commercial system equipped with high-frame rate vector flow imaging (VFI) based on the plane wave and to compare VFI with color Doppler imaging. MethodsCarotid bifurcation diameters and flow characteristics of 60 vessels in 60 healthy volunteers were evaluated quantitatively and qualitatively to assess complex flow patterns and their extension and duration. ResultsComplex flow in the internal carotid artery (ICA) was associated with a statistically significant difference in the ICA sinus-to-common carotid artery (CCA) diameter ratio (the relative change in diameter between the CCA and ICA sinus.) Vector flow imaging and color Doppler imaging were in accordance when detecting complex flow in 96.7% of cases; in 3.3% of cases, only VFI identified small recirculation areas of short duration. Vector flow imaging highlighted a larger extension of the complex flow (meanSD, 47.7 +/- 28.5 mm(2); median, 45.5 mm(2)) compared with color Doppler imaging (mean, 29.2 +/- 19.9 mm(2); median, 29.5 mm(2)) and better depicted different complex flow patterns; a strong correlation (r=0.84) was found between the ICA sinus-to-CCA diameter ratio and the complex flow extension. Vector flow imaging showed a longer duration of the flow disturbances (mean, 380 +/- 218 milliseconds; median, 352.5 milliseconds) compared with color Doppler imaging (mean, 325 +/- 206 milliseconds; median, 333 milliseconds), and there was a strong correlation (r=0.92). ConclusionsVector flow imaging is as effective as color Doppler imaging in the detection of flow disturbances, but it is more powerful in the assessment of complex flow patterns.
引用
收藏
页码:2263 / 2275
页数:13
相关论文
共 50 条
  • [31] DOPPLER COLOR FLOW IMAGING OF CAROTID-BODY TUMORS
    STEINKE, W
    HENNERICI, M
    AULICH, A
    STROKE, 1989, 20 (11) : 1574 - 1577
  • [32] COLOR-FLOW DOPPLER IMAGING OF A CAROTID CAVERNOUS FISTULA
    MUNK, PL
    DOWNEY, D
    PELZ, D
    VELLET, AD
    NICOLLE, DA
    LEVIN, MF
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1992, 43 (03): : 227 - 229
  • [33] Evaluation of Turbulence Index and Flow Pattern for Atherosclerotic Carotid Stenosis: A High-Frame-Rate Vector Flow Imaging Study
    Dong, Yinghui
    Gao, Wenjing
    Hong, Shaofu
    Song, Di
    Liu, Mengmeng
    Du, Yigang
    Xu, Jinfeng
    Dong, Fajin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (04): : 549 - 556
  • [34] Real-Time System for High Frame Rate Vector Flow Imaging
    Rossi, S.
    Acerbi, F.
    Dallai, A.
    Guidi, F.
    Meacci, V
    Ramalli, A.
    Tortoli, P.
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [35] High frame rate synthetic aperture vector flow imaging for transthoracic echocardiography
    Villagomez-Hoyos, Carlos A.
    Stuart, Matthias B.
    Bechsgaard, Thor
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [36] Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging
    Du, Yigang
    Ding, Haiyan
    He, Le
    Yiu, Billy Y. S.
    Deng, Linsong
    Yu, Alfred C. H.
    Zhu, Lei
    DIAGNOSTICS, 2022, 12 (03)
  • [37] High-frame rate imaging of two-phase flow in a thin rectangular channel using fast neutrons
    Zboray, R.
    Mor, I.
    Dangendorf, V.
    Stark, M.
    Tittelmeier, K.
    Cortesi, M.
    Adams, R.
    APPLIED RADIATION AND ISOTOPES, 2014, 90 : 122 - 131
  • [38] High Frame Rate Ultrasound Displacement Vector Imaging
    Kruizinga, Pieter
    Mastik, Frits
    Bosch, Johannes G.
    de Jong, Nico
    van Soest, Gijs
    van der Steen, Antonius F. W.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 707 - 709
  • [39] CINE MR IMAGING IN MITRAL REGURGITATION - COMPARISON WITH COLOR DOPPLER FLOW IMAGING
    NISHIMURA, T
    YAMADA, N
    ITOH, A
    MIYATAKE, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (04) : 721 - 724
  • [40] DOPPLER COLOR FLOW IMAGING OF COMMON CAROTID-ARTERY DISSECTION
    STEINKE, W
    SCHWARTZ, A
    HENNERICI, M
    NEURORADIOLOGY, 1990, 32 (06) : 502 - 505