High-Frame Rate Vector Flow Imaging of the Carotid Bifurcation in Healthy Adults: Comparison With Color Doppler Imaging

被引:32
|
作者
Goddi, Alfredo [1 ]
Bortolotto, Chandra [2 ]
Raciti, Maria Vittoria [2 ]
Fiorina, Ilaria [2 ]
Aiani, Luca [1 ]
Magistretti, Giovanni [1 ]
Sacchi, Andrea [1 ]
Tinelli, Carmine [3 ]
Calliada, Fabrizio [2 ]
机构
[1] Ctr Med SME Diagnost Immagini, Varese, Italy
[2] Univ Pavia, Radiol Unit, Fdn Ist Ricovero & Cura Carattere Sci Policlin Sa, Viale Oberdan 21, I-27100 Pavia, Italy
[3] Fdn Ist Ricovero & Cura Carattere Sci Policlin Sa, Clin Epidemiol & Biometr Unit, Pavia, Italy
关键词
carotid arteries; Doppler imaging; hemodynamic; plane wave imaging; ultrasound; vascular (diagnostic); vector flow imaging; WALL SHEAR-STRESS; BLOOD-FLOW; VELOCITY ESTIMATION; TRANSIENT ELASTOGRAPHY; PLANE-WAVES; ULTRASOUND; ATHEROSCLEROSIS; VISUALIZATION; ATHEROGENESIS; PATTERNS;
D O I
10.1002/jum.14579
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
ObjectivesTo evaluate the carotid bifurcation in healthy adults using a commercial system equipped with high-frame rate vector flow imaging (VFI) based on the plane wave and to compare VFI with color Doppler imaging. MethodsCarotid bifurcation diameters and flow characteristics of 60 vessels in 60 healthy volunteers were evaluated quantitatively and qualitatively to assess complex flow patterns and their extension and duration. ResultsComplex flow in the internal carotid artery (ICA) was associated with a statistically significant difference in the ICA sinus-to-common carotid artery (CCA) diameter ratio (the relative change in diameter between the CCA and ICA sinus.) Vector flow imaging and color Doppler imaging were in accordance when detecting complex flow in 96.7% of cases; in 3.3% of cases, only VFI identified small recirculation areas of short duration. Vector flow imaging highlighted a larger extension of the complex flow (meanSD, 47.7 +/- 28.5 mm(2); median, 45.5 mm(2)) compared with color Doppler imaging (mean, 29.2 +/- 19.9 mm(2); median, 29.5 mm(2)) and better depicted different complex flow patterns; a strong correlation (r=0.84) was found between the ICA sinus-to-CCA diameter ratio and the complex flow extension. Vector flow imaging showed a longer duration of the flow disturbances (mean, 380 +/- 218 milliseconds; median, 352.5 milliseconds) compared with color Doppler imaging (mean, 325 +/- 206 milliseconds; median, 333 milliseconds), and there was a strong correlation (r=0.92). ConclusionsVector flow imaging is as effective as color Doppler imaging in the detection of flow disturbances, but it is more powerful in the assessment of complex flow patterns.
引用
收藏
页码:2263 / 2275
页数:13
相关论文
共 50 条
  • [21] High frame rate tissue Doppler imaging
    Bjærum, S
    Torp, H
    Kristoffersen, K
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1417 - 1421
  • [22] A high-frame rate duplex ultrasound biomicroscopy for small animal imaging in vivo
    Sun, Lei
    Xu, Xiaochen
    Richard, William D.
    Feng, Ching
    Johnson, Jeffrey A.
    Shung, K. Kirk
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (08) : 2039 - 2049
  • [23] A high-frame rate high-frequency ultrasonic system for cardiac imaging in mice
    Sun, Lei
    Richard, William D.
    Cannata, Jonathan M.
    Feng, Ching C.
    Johnson, Jeffrey A.
    Yen, Jesse T.
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (08) : 1648 - 1655
  • [24] A new technique for improved spatial resolution in high frame rate color Doppler imaging
    Kirkhorn, J
    Bjærum, S
    Olstad, B
    Kristoffersen, K
    Torp, H
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 1947 - 1950
  • [25] High frame rate doppler ultrasound bandwidth imaging for flow instability mapping
    Yiu, Billy Y. S.
    Chee, Adrian J. Y.
    Tang, Guo
    Luo, Wenbo
    Yu, Alfred C. H.
    MEDICAL PHYSICS, 2019, 46 (04) : 1620 - 1633
  • [26] Extended high-frame rate imaging method with limited-diffraction beams
    Cheng, JQ
    Lu, JY
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (05) : 880 - 899
  • [27] A novel envelope detector for high-frame rate, high-frequency ultrasound imaging
    Chang, Jin Ho
    Yen, Jesse T.
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (09) : 1792 - 1801
  • [28] EXAMINATION OF CAROTID ARTERIES WITH QUANTITATIVE COLOR DOPPLER FLOW IMAGING
    BRANAS, CC
    WEINGARTEN, MS
    CZEREDARCZUK, M
    SCHAFER, PF
    JOURNAL OF ULTRASOUND IN MEDICINE, 1994, 13 (02) : 121 - 127
  • [29] DOPPLER COLOR FLOW IMAGING OF CAROTID-ARTERY DISSECTION
    BLUTH, EI
    SHYN, PB
    SULLIVAN, MA
    MERRITT, CRB
    JOURNAL OF ULTRASOUND IN MEDICINE, 1989, 8 (03) : 149 - 153
  • [30] COLOR DOPPLER FLOW IMAGING - CRITERIA FOR EVALUATING CAROTID STENOSIS
    BRANAS, CC
    CZEREDARCZUK, M
    FERRERO, PA
    WEINGARTEN, MS
    WOLFERTH, CC
    STROKE, 1992, 23 (03) : 459 - 459