Intrapartum surveillance of IUGR fetuses with cardiotocography and fetal pulse oximetry

被引:1
|
作者
Siristatidis, C [1 ]
Salamalekis, E [1 ]
Vitoratos, N [1 ]
Loghis, C [1 ]
Salloum, J [1 ]
Kassanos, D [1 ]
Panayotopoulos, N [1 ]
Creatsas, G [1 ]
机构
[1] Univ Athens, Sch Med, Dept Obstet & Gynecol 2, Aretaieion Hosp, GR-11527 Athens, Greece
来源
BIOLOGY OF THE NEONATE | 2003年 / 83卷 / 03期
关键词
intrauterine growth retardation; fetal pulse oximetry; fetal hypoxia during labor;
D O I
10.1159/000068923
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: To investigate the efficacy and safety of intrapartum fetal pulse oximetry, as a predictor of metabolic acidosis at birth of fetuses with intrauterine growth retardation (IUGR). Study Design: We studied 18 IUGR fetuses (group I) and a control group of 30 appropriate for gestational age (AGA) fetuses (group II) during labor. Both groups had abnormal fetal heart rate tracings and were monitored simultaneously throughout labor with cardiotocography and fetal pulse oximetry. Apgar scores, pH and base excess of fetal blood obtained from the umbilical artery after delivery were compared in both groups. Setting: The Fetal Surveillance Unit of the 2nd Department of Obstetrics and Gynecology, Aretaieion Hospital, Medical. School, Athens University. Results: In IUGR fetuses, when their oxygen saturation value (FSPO2) was less than 34%, cord artery pH was 7.10 +/- 0.04, base excess-13 +/- -1 mmol/l and Apgarscores less than or equal to 5 at the 5th min, and when FSPO2 was over 35%, artery pH was 7.29 +/- 0.08, base excess -8 +/- -2 mmol/l and Apgar scores greater than or equal to 7 at the 5th minute. In cases of drops of FSPO2 below 30% for more than 2 min, labor was completed operatively and cord pH was 7.00 +/- 0.04, base excess -15 +/- -2 mmol/l and Apgar scores less than or equal to 5 at the 5th minute. In AGA fetuses, when FSPO2 was over 30%, artery pH was over 7.20, base excess <-11 mmol/l and Apgar scores 2 9 at the 5th minute; in contrast, when FSPO2 was <30% for 2 min, a cesarean section was performed and cord pH was less than or equal to 7.02, base excess greater than or equal to -13 mmol/l and Apgarscores less than or equal to 4 at the 5th minute. Conclusions: In IUGR fetuses, FSPO2 values less than 34% represent an acidotic status, while values of greater than or equal to 35% are well tolerated. Fetal pulse oximetry proved reliable, according to umbilical cord blood measurements and Apgar scores, reducing cesarean deliveries in cases of nonreassuring cardiotocographic patterns in IUGR fetuses. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:162 / 165
页数:4
相关论文
共 50 条
  • [31] Cardiotocography and ST analysis for intrapartum fetal monitoring
    Leipala, Jaana
    Ojala, Kati
    Stefanovic, Vedran
    Makela, Marjukka
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2012, 91 (04) : 518 - 518
  • [32] Cardiotocography patterns and risk of intrapartum fetal acidemia
    Holzmann, Malin
    Wretler, Stina
    Cnattingius, Sven
    Nordstrom, Lennart
    [J]. JOURNAL OF PERINATAL MEDICINE, 2015, 43 (04) : 473 - 479
  • [33] Intrapartum cardiotocography in pregnancies with and without fetal CHD
    Feduniw, Stepan
    Muzyka-Placzynska, Katarzyna
    Kajdy, Anna
    Wrona, Marcin
    Sys, Dorota
    Szymkiewicz-Dangel, Joanna
    [J]. JOURNAL OF PERINATAL MEDICINE, 2022, 50 (07) : 961 - 969
  • [34] Cardiotocography and ST analysis for intrapartum fetal monitoring
    Hanson, Ulf
    [J]. LANCET, 2011, 378 (9797): : 1137 - 1138
  • [35] Effectiveness of pulse oximetry versus fetal electrocardiography for the intrapartum evaluation of nonreassuring fetal heart rate
    Valverde, Mercedes
    Puertas, Alberto M.
    Lopez-Gallego, Maria F.
    Carrillo, Maria P.
    Aguilar, Maria T.
    Montoya, Francisco
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2011, 159 (02) : 333 - 337
  • [36] INTRAPARTUM FETAL PULSE OXIMETRY - THE EFFECTS OF MATERNAL HYPEROXIA ON FETAL ARTERIAL OXYGEN-SATURATION
    DILDY, GA
    CLARK, SL
    LOUCKS, CA
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (04) : 1120 - 1124
  • [37] How well does reflectance pulse oximetry reflect intrapartum fetal acidosis?
    Stiller, R
    von Mering, R
    König, V
    Huch, A
    Huch, R
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2002, 186 (06) : 1351 - 1357
  • [38] Intrapartum fetal pulse oximetry. Part I: Principles and technical issues
    Yam, J
    Chua, S
    Arulkumaran, S
    [J]. OBSTETRICAL & GYNECOLOGICAL SURVEY, 2000, 55 (03) : 163 - 172
  • [39] Intrapartum fetal surveillance
    Jibodu, OA
    Arulkumaran, S
    [J]. CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2000, 12 (02) : 123 - 127
  • [40] Cardiotocography and ST analysis for intrapartum fetal monitoring Reply
    Marsal, Karel
    [J]. LANCET, 2011, 378 (9797): : 1138 - 1138