Effectiveness of pulse oximetry versus fetal electrocardiography for the intrapartum evaluation of nonreassuring fetal heart rate

被引:10
|
作者
Valverde, Mercedes [2 ]
Puertas, Alberto M. [1 ]
Lopez-Gallego, Maria F. [1 ,3 ]
Carrillo, Maria P. [1 ]
Aguilar, Maria T. [1 ]
Montoya, Francisco [1 ]
机构
[1] Virgen de las Nieves Univ Hosp, Obstet & Gynecol Serv, Granada 18014, Spain
[2] Santa Ana Hosp, Obstet & Gynecol Serv, Granada, Spain
[3] El Poniente Hosp, Obstet & Gynecol Serv, El Poniente, Almeria, Spain
关键词
Intrapartum fetal monitoring; Fetal pulse oximetry; Fetal electrocardiography; STAN21; Nonreassuring fetal heart rate; CONTROLLED TRIAL; ST ANALYSIS; CARDIOTOCOGRAPHY; MULTICENTER; ACIDOSIS;
D O I
10.1016/j.ejogrb.2011.09.021
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objectives: To compare the effectiveness of pulse oximetry and fetal electrocardiography in the management of labor with nonreassuring fetal heart rate (NRFHR). Study design: This randomized experimental study consisted of two arms. In group 1 we used pulse oximetry and in group 2 we used STAN technology. The participants in each group were 90 pregnant women with a full-term singleton fetus in cephalic presentation and cardiotocographic tracings compatible with NRFHR. We compared the following variables: rate of cesarean delivery, indications for operative delivery due to NRFHR, and repercussions on the newborn's acid-base status. Results: The two groups differed significantly in the mode of delivery, with a cesarean delivery rate of 47.6% in group 1 vs. 30% in group 2 (p = 0.032). The groups did not differ in the indications for ending labor due to NRFHR (62% vs. 61%, NS). In terms of neonatal outcomes, the 1-min Apgar score was 6 or lower in 17.8% of the group 1 neonates vs. 4.44% of the group 2 neonates (p < 0.001). The groups also differed significantly in umbilical cord vein pH (7.23 vs. 7.27) and pCO(2) (57.27 vs. 46.86) at birth. Conclusions: Fetal electrocardiography with the STAN 21 system was more effective in detecting good fetal status and thus in identifying cases in which labor could proceed safely. Intrapartum surveillance with the STAN 21 system reduced the rate of emergency cesarean delivery. Crown Copyright (C) 2011 Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 50 条
  • [1] Fetal pulse oximetry in intrapartum management of nonreassuring fetal heart rate patterns - Reply
    Garite, TJ
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 185 (03) : 771 - 772
  • [2] A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns
    Garite, TJ
    Dildy, GA
    McNamara, H
    Nageotte, MP
    Boehm, FH
    Dellinger, EH
    Knuppel, RA
    Porreco, RP
    Miller, HS
    Sunderji, S
    Varner, MW
    Swedlow, DB
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2000, 183 (05) : 1049 - 1058
  • [3] Intrapartum management of nonreassuring fetal heart rate patterns:: A randomized controlled trial of fetal pulse oximetry
    Kühnert, M
    Schmidt, S
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (06) : 1989 - 1995
  • [4] Intrapartum fetal pulse oximetry and fetal heart rate decelerations
    Puertas, A
    Navarro, M
    Velasco, R
    Montoya, E
    Miranda, JA
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2004, 85 (01) : 12 - 17
  • [5] Effectiveness of fetal electrocardiography versus pulse oximetry to determine fetal well-being
    Lopez, J. E. Martin
    Calvo, C. Beltran
    Lopez, R. Rodriguez
    [J]. CLINICA E INVESTIGACION EN GINECOLOGIA Y OBSTETRICIA, 2015, 42 (04): : 157 - 164
  • [6] Fetal pulse oximetry:: Correlation with intrapartum fetal heart rate patterns and neonatal outcome
    Tekin, Arzu
    Oezkan, Sebiha
    Caliskan, Eray
    Oezeren, Semih
    Corakci, Aydin
    Yuecesoy, Izzet
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2008, 34 (05) : 824 - 831
  • [7] The effect of intrapartum fetal pulse oximetry, in the presence of a nonreassuring fetal heart rate pattern, on operative delivery rates: A multicenter, randomized, controlled trial (the FOREMOST trial)
    East, CE
    Brennecke, SP
    King, JF
    Chan, FY
    Colditz, PB
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 194 (03) : 606 - 616
  • [8] Evaluation of intrapartum fetal well-being by fetal pulse oximetry
    Amano, K
    Hirano, S
    Nishijima, M
    [J]. LABOR AND DELIVERY, 1998, : 396 - 399
  • [9] The effect of maternal oxygen administration on fetal pulse oximetry during labor in fetuses with nonreassuring fetal heart rate patterns
    Haydon, Michael L.
    Gorenberg, David M.
    Nageotte, Michael P.
    Ghamsary, Mark
    Rumney, Pamela I.
    Patillo, Carol
    Garite, Thomas J.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 195 (03) : 735 - 738
  • [10] Fetal pulse oximetry improves intrapartum fetal assessment
    Carrillo, J
    Insunza, A
    Latorre, R
    Mercado, M
    Cardenas, F
    Novoa, JM
    Paiva, E
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 189 (06) : S184 - S184